Inter- and Intra-rater Reliability of A Grading System for Congenital Diaphragmatic Hernia Defect Size

Date
2019-01
Language
English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Elsevier
Abstract

Background The Congenital Diaphragmatic Hernia Study Group (CDHSG) registry is a multi-institutional tool to track outcomes of patients with CDH. The CDHSG asks surgeons to categorize diaphragmatic defect sizes as type A-D based on published guidelines. The reported size of the defect has been correlated with patient outcomes, but the reliability of this system has never been studied. Our goal was to evaluate the inter- and intra-rater reliability of the CDHSG grading system.

Materials and methods Forty-six operative notes from CDH patients that underwent surgical repair at a single institution were collected and cropped to include only the information necessary to grade the hernia defect based on the CDHSG guidelines. The defects were graded by nine pediatric surgeons on two separate occasions (18 wk apart). Inter-rater reliability was calculated using a Cohen's kappa (κ). Intra-rater reliability was calculated using an intraclass correlation coefficient.

Results Inter-rater reliability was minimal to weak (κ round1 = 0.395, κ round2 = 0.424). Agreement ranged from 19.57% (κ = −0.0745) to 82.61% (κ = 0.7543). Inter-rater agreement was similar despite operative findings and outcomes: survival yes/no (κ = 0.3690, κ = 0.3518), need for ECMO yes/no (κ = 0.3323, κ = 0.3362), patch repair yes/no (κ = 0.2050, κ = 0.1916), and liver up/down (κ = 0.2941, κ = 0.4404).

Intra-rater reliability was good to excellent (intraclass correlation coefficient = 0.88, 95% CI [0.83-0.92]). Agreement with oneself ranged from 71.74% to 93.48%.

Conclusions The demonstrated weak inter-rater reliability of the current CDHSG grading system shows the need for improvement in how the grading system is applied by surgeons when reporting CDH defect size.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Hunter, C. E., Saenz, Z. M., Nunez, D., Timsina, L., & Gray, B. W. (2019). Inter- and Intra-rater Reliability of A Grading System for Congenital Diaphragmatic Hernia Defect Size. Journal of Surgical Research, 233, 82–87. https://doi.org/10.1016/j.jss.2018.07.045
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Journal of Surgical Research
Rights
Publisher Policy
Source
Author
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}