Long-Term Follow-Up of Colonoscopy Quality Monitoring

Date
2023-09-01
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Wolters Kluwer
Abstract

Introduction: High-quality colonoscopy is paramount for colorectal cancer prevention. Since 2009, endoscopists at our institution have received quarterly report cards summarizing individual colonoscopy quality indicators. We have previously shown that implementing this intervention was associated with short-term improvement in adenoma detection rate (ADR). However, the long-term effect of continued monitoring on colonoscopy quality is unclear.

Methods: We conducted a retrospective study of prospectively administered quarterly colonoscopy quality report cards at the Roudebush Veteran's Affairs Medical Center between April 1, 2012, and August 31, 2019. The anonymized reports included individual endoscopists' ADRs, cecal intubation rates, and withdrawal times. Analyses were performed to determine slopes over time for each quality metric by physician and assess for differences based on whether ADRs were calculated quarterly or yearly.

Results: Data from the report cards of 17 endoscopists who had performed 24,361 colonoscopies were included. The mean quarterly ADR (±SD) was 51.7% (±11.7%) and mean yearly ADR was 47.2% (±13.8%). There was a small increase in overall ADR based on quarterly and yearly measurements (slope + 0.6%, P = 0.02; and slope +2.7%, P < 0.001, respectively), but no significant change in individual ADRs, cecal intubation rates, or withdrawal times. Analysis of SD of ADRs showed no significant difference between yearly and quarterly measurements ( P = 0.064). Individual endoscopists' ADR SD differences between yearly and quarterly measurements ranged from -4.7% to +6.8%.

Discussion: Long-term colonoscopy quality monitoring paralleled stable improvements in overall ADR. For endoscopists with baseline high ADR, frequent monitoring and reporting of colonoscopy quality metrics may not be necessary.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Patel F, Dilly C, Fayad N, Marri S, Eckert GJ, Kahi C. Long-Term Follow-Up of Colonoscopy Quality Monitoring. Clin Transl Gastroenterol. 2023;14(9):e00608. Published 2023 Sep 1. doi:10.14309/ctg.0000000000000608
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Clinical and Translational Gastroenterology
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Final published version
Full Text Available at
This item is under embargo {{howLong}}