The Influence of Distance on Radiant Exposure and Degree of Conversion Using Different Light-Emitting-Diode Curing Units

dc.contributor.authorAl-Zain, A.O.
dc.contributor.authorEckert, G. J.
dc.contributor.authorPlatt, J. A.
dc.contributor.departmentBiomedical Sciences and Comprehensive Care, School of Dentistryen_US
dc.date.accessioned2020-08-06T20:41:45Z
dc.date.available2020-08-06T20:41:45Z
dc.date.issued2019-05
dc.description.abstractObjectives: To investigate the influence of curing distance on the degree of conversion (DC) of a resin-based composite (RBC) when similar radiant exposure was achieved using six different light-curing units (LCUs) and to explore the correlation among irradiance, radiant exposure, and DC. Methods and Materials: A managing accurate resin curing-resin calibrator system was used to collect irradiance data for both top and bottom specimen surfaces with a curing distance of 2 mm and 8 mm while targeting a consistent top surface radiant exposure. Square nanohybrid-dual-photoinitiator RBC specimens (5 × 5 × 2 mm) were cured at each distance (n=6/LCU/distance). Irradiance and DC (micro-Raman spectroscopy) were determined for the top and bottom surfaces. The effect of distance and LCU on irradiance, radiant exposure, and DC as well as their linear associations were analyzed using analysis of variance and Pearson correlation coefficients, respectively (α=0.05). Results: While maintaining a similar radiant exposure, each LCU exhibited distinctive patterns in decreased irradiance and increased curing time. No significant differences in DC values (63.21%-70.28%) were observed between the 2- and 8-mm distances, except for a multiple-emission peak LCU. Significant differences in DC were detected among the LCUs. As expected, irradiance and radiant exposure were significantly lower on the bottom surfaces. However, a strong correlation between irradiance and radiant exposure did not necessarily result in a strong correlation with DC. Conclusions: The RBC exhibited DC values >63% when the top surface radiant exposure was maintained, although the same values were not reached for all lights. A moderate-strong correlation existed among irradiance, radiant exposure, and DC.en_US
dc.eprint.versionFinal published versionen_US
dc.identifier.citationAl-Zain, A. O., Eckert, G. J., & Platt, J. A. (2019). The Influence of Distance on Radiant Exposure and Degree of Conversion Using Different Light-Emitting-Diode Curing Units. Operative Dentistry, 44(3), E133–E144. https://doi.org/10.2341/18-004-Len_US
dc.identifier.urihttps://hdl.handle.net/1805/23553
dc.language.isoenen_US
dc.publisherAllen Pressen_US
dc.relation.isversionof10.2341/18-004-Len_US
dc.relation.journalOperative Dentistryen_US
dc.rightsPublisher Policyen_US
dc.sourcePublisheren_US
dc.subjectdegree of conversionen_US
dc.subjectresin-based compositeen_US
dc.subjectradiant exposureen_US
dc.titleThe Influence of Distance on Radiant Exposure and Degree of Conversion Using Different Light-Emitting-Diode Curing Unitsen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Al-Zain2019Influence.pdf
Size:
807.12 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: