Dynamic assessment of the tear film muco-aqueous and lipid layers using a novel tear film imager (TFI)

If you need an accessible version of this item, please email your request to digschol@iu.edu so that they may create one and provide it to you.
Date
2020
Language
English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
BMJ
Abstract

Purpose The objective of the study was to assess a new technology, the tear film imager (TFI), which can dynamically image the muco-aqueous and lipid layers.

Methods Prospective pilot case series of individuals with and without dry eye (DE). Two sequential images were obtained with the TFI. Measurements were assessed for reproducibility and compared with clinically derived DE metrics. Individuals were grouped into DE categories based on signs of DE.

Results 49 patients participated in the study with a mean age of 58.8 years (SD 15.9) and a female majority (69%). Reproducibility of the muco-aqueous layer thickness (MALT) was excellent (r=0.88). MALT measurements significantly correlated with the Schirmer score (r=0.31). Lipid break up time (LBUT) as measured by the TFI significantly correlated with the clinical measure of tear break up time (TBUT) (r=0.73). MALT and LBUT were significantly thinner and shorter, respectively, in the DE groups (mild–moderate and severe) compared with the control group. When comparing TFI parameters to clinically assessed signs, sensitivity of the device was 87% and specificity was 88%.

Conclusion The TFI is the first machine capable of reproducibly measuring muco-aqueous thickness in human subjects which correlates with Schirmer score. In parallel, it assesses other important aspects of tear film function which correlate with clinician assessed DE metrics.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Segev, F., Geffen, N., Galor, A., Cohen, Y., Gefen, R., Belkin, A., Arieli, Y., Epshtein, S., Oren, A., & Harris, A. (2020). Dynamic assessment of the tear film muco-aqueous and lipid layers using a novel tear film imager (TFI). British Journal of Ophthalmology, 104(1), 136–141. https://doi.org/10.1136/bjophthalmol-2018-313379
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
British Journal of Ophthalmology
Source
Author
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}