Endoscopic Ultrasound-Guided Drainage of Intra-Abdominal Abscess Using 15-mm vs. 10-mm Lumen-Apposing Metal Stents: An International Case-Matched Study
Date
Authors
Language
Embargo Lift Date
Department
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Abstract
Background and Aims Efficacy and safety of EUS-guided placement of lumen-apposing metal stents (LAMS) has been reported yet advantage of using 15-mm LAMS over 10-mm LAMS yet to be explored. Methods International, retrospective, case-matched study of patients with intra-abdominal abscess who underwent EUS-guided drainage with 15-mm (case) and 10-mm (control) LAMS between 03/2019 and 09/2022. Results 51 patients underwent EUS-guided drainage using LAMS [15-mm 29 (57%), 10-mm 22 (43%)]. The most common location of the abscess was peri-pancreatic 43%. Technical success rate was achieved in 97% of cases and 100 % of controls (p=0.412), while clinical success was achieved in 98% and 96%, respectively, (OR 1.3; p=0.089). AE occurred in 7.8% of the cases. Patients with 15-mm LAMS underwent fewer total endoscopic procedures (mean 2.5 vs.3.6; P < 0.023). Conclusion Both sizes showed comparable clinical success and safety profiles, with a significant trend of the need for fewer endoscopic procedures with the 15-mm LAMS.