Yield of a second screening colonoscopy 10 years after an initial negative examination in average-risk individuals
Date
Language
Embargo Lift Date
Department
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Abstract
Background and Aims
Current guidelines recommend screening colonoscopy at 10-year intervals in average-risk individuals who had baseline screening colonoscopy (no polyps or only hyperplastic polyps ≤5 mm in the recto-sigmoid colon), but the yield of repeat screening at 10 years is unknown. Our aim was to describe the yield of second screening colonoscopy in average-risk individuals performed at least 8 years after a first screening colonoscopy had shown no polyps or only distal hyperplastic polyps ≤5 mm in size.
Methods
This was a review of a database for colonoscopies performed at Indiana University Hospital between January 1999 and November 2015.
Results
A total of 4463 individuals underwent screening colonoscopy between January 1999 and July 2007, of which 1566 individuals had no polyps, and 334 individuals had only distal hyperplastic polyps ≤5 mm; 378 individuals (58.4% female) had follow-up screening at least 8 years after the baseline screening examination, with a mean (± standard deviation [SD]) interval of 9.74 years (± 1.2 years; range 8-15 years). Mean (± SD) age at baseline screening examination was 56.7 years (± 5.5 years) and at follow-up screening examination was 66.4 years (± 5.6 years). At the second screening, there were 224 patients (59.3%) with at least 1 polyp, including 144 (38.1%) with at least 1 conventional adenoma. The adenoma detection rate at the second screening examination was 36.1% and 56.8% in the groups with no polyp at baseline and with only distal hyperplastic polyps, respectively. There were 15 advanced neoplasms in 13 individuals (3.4%), of which 12 lesions were proximal to the sigmoid colon. There were no cancers at follow-up.
Conclusions
Among individuals aged ≥50 years, with normal baseline screening colonoscopy results, the incidence of advanced lesions at a second screening colonoscopy at least 8 years later was comparable to that in baseline screening studies. Our findings support current recommendations for screening at 10-year intervals in average-risk individuals.