Quantification of three-dimensional orthodontic force systems of T-loop archwires

dc.contributor.authorChen, Jie
dc.contributor.authorIsikbay, Serkis C.
dc.contributor.authorBrizendine, Edward J.
dc.contributor.departmentOrthodontics and Oral Facial Genetics, School of Dentistryen_US
dc.date.accessioned2020-05-13T18:48:26Z
dc.date.available2020-05-13T18:48:26Z
dc.date.issued2010-07-01
dc.description.abstractObjective: To demonstrate the three-dimensional (3D) orthodontic force systems of three commercial closing T-loop archwires using a new method and to quantify the force systems of the T-loop archwires. Materials and Methods: An orthodontic force tester (OFT) and a custom-made dentoform were developed to measure force systems. The system simulated the clinical environment for an orthodontic patient requiring space closure, which included measurement of three force components along, and three moment components about, three clinically defined axes on two target teeth. The archwires were attached to the dentoform and were activated following a standard clinical procedure. The resulting force system was measured using the OFT. Results: The force systems of the T-loops on the teeth were 3D. Activation in one direction resulted in force and moment components in other directions (side effects). The six force and moment components as well as the moment-to-force ratios in the clinically defined coordinate system were quantified. Conclusions: The commercial archwires do not provide force systems for pure translation. Quantification of the force system is critical for the selection and design of optimal orthodontic appliances.en_US
dc.eprint.versionFinal published versionen_US
dc.identifier.citationJie Chen, Serkis C. Isikbay, Edward J. Brizendine; Quantification of three-dimensional orthodontic force systems of T-loop archwires. Angle Orthod 1 July 2010; 80 (4): 754–758. doi: https://doi.org/10.2319/082509-484.1en_US
dc.identifier.urihttps://hdl.handle.net/1805/22760
dc.language.isoen_USen_US
dc.publisherE.H Angle Education and Research Foundationen_US
dc.relation.isversionof10.2319/082509-484.1en_US
dc.relation.journalAngle Orthodontisten_US
dc.rightsAttribution-ShareAlike 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-sa/4.0/*
dc.sourcePublisheren_US
dc.subjectOrthodontic force systemen_US
dc.subjectBiomechanicsen_US
dc.titleQuantification of three-dimensional orthodontic force systems of T-loop archwiresen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
082509-484_1.pdf
Size:
507.94 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: