Introduction: High temperature alkaline hydrolysis (AH) is recognized as an alternative method for sterilization and disposition of animal carcasses and human remains. The aim of this study is to validate the low temperature (LT) AH process specific to its use in the Bio-Response Solutions, Inc. Human-28 LT System.

Methods: A 313-lb pig was processed using the manufacturers recommended cycle parameters. Stainless steel sample vials containing spore suspensions of Geobacillus stearothermophilus were implanted into the pig's deep tissue to validate the efficacy of the process conditions. Spore suspensions of Bacillus thuringiensis were suspended in the vessel headspace to validate sterilization. The spore challenge was greater than the recommended 106 log used to determine sterilization. MALDI-TOF mass spectrometry analysis was used to validate the destruction of prion-sized particles in processed effluent.

Results: Complete inactivation of spores and digestion of animal tissue were achieved after processing in the Bio-Response Solutions Human-28 LT Alkaline Hydrolysis System. Complete inactivation of spores was achieved when exposed to heat in the animal carcass and headspace. No peptide fragments larger than 2500 Da were observed in the treatment effluent.

Discussion: The Bio-Response Solutions, Inc. Human-28 LT Alkaline Hydrolysis System was as effective as high-temperature alkaline hydrolysis for use on animal and human tissue.

Conclusion: LT AH for tissue and bodies exceeded the sterility assurance level III of the US State and Territorial Association on Alternative Treatment Technologies and sterility requirements for animal biosafety level-3 and -4 facilities. LT AH process validated destruction of prion-sized particles.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Denys GA. Validation of the Bio-Response Solutions Human-28 Low-Temperature Alkaline Hydrolysis System. Appl Biosaf. 2019;24(4):182-188. doi:10.1177/1535676019871389
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Applied Biosafety
Rights
Publisher Policy
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Final published version
This item is under embargo {{howLong}}