Validation of the triple timed up‐and‐go test in Lambert‐Eaton myasthenia

dc.contributor.authorRaja, Shruti M.
dc.contributor.authorSanders, Donald B.
dc.contributor.authorJuel, Vern C.
dc.contributor.authorHarati, Yadollah
dc.contributor.authorSmith, A. Gordon
dc.contributor.authorPascuzzi, Robert
dc.contributor.authorRichman, David P.
dc.contributor.authorWu, Angie
dc.contributor.authorAleš, Kathy L.
dc.contributor.authorJacobus, Laura R.
dc.contributor.authorJacobus, David P.
dc.contributor.authorGuptill, Jeffrey T.
dc.contributor.departmentNeurology, School of Medicineen_US
dc.date.accessioned2020-09-18T21:55:43Z
dc.date.available2020-09-18T21:55:43Z
dc.date.issued2019-09
dc.description.abstractIntroduction There are no validated, practical, and quantitative measures of disease severity in Lambert‐Eaton myasthenia (LEM). Methods Data from the Effectiveness of 3,4‐Diaminopyridine in Lambert‐Eaton Myasthenic Syndrome (DAPPER) trial were analyzed to assess triple timed up‐and‐go (3TUG) reproducibility and relationships between 3TUG times and other measures of LEM severity. Results The coverage probability technique showed ≥0.90 probability for an acceptable 3TUG difference of ≤0.2, indicating that it is reproducible in LEM patients. The correlation between 3TUG times and lower extremity function scores was significant in subjects who continued and in those who were withdrawn from 3,4‐diaminopyridine free base. Worsening patient‐reported Weakness Self‐Assessment Scale and Investigator Assessment of Treatment Effect scores corresponded with prolongation of 3TUG times. Discussion The 3TUG is reproducible, demonstrates construct validity for assessment of lower extremity function in LEM patients, and correlates with changes in patient and physician assessments. These findings, along with prior reliability studies, indicate 3TUG is a valid measure of disease severity in LEM.en_US
dc.eprint.versionFinal published versionen_US
dc.identifier.citationRaja, S. M., Sanders, D. B., Juel, V. C., Harati, Y., Smith, A. G., Pascuzzi, R., Richman, D. P., Wu, A., Aleš, K. L., Jacobus, L. R., Jacobus, D. P., & Guptill, J. T. (2019). Validation of the triple timed up‐and‐go test in Lambert‐Eaton myasthenia. Muscle & Nerve, 60(3), 292–298. https://doi.org/10.1002/mus.26625en_US
dc.identifier.urihttps://hdl.handle.net/1805/23889
dc.language.isoenen_US
dc.publisherWileyen_US
dc.relation.isversionof10.1002/mus.26625en_US
dc.relation.journalMuscle & Nerveen_US
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourcePublisheren_US
dc.subjectLambert‐Eaton myastheniaen_US
dc.subjectLambert‐Eaton myasthenic syndromeen_US
dc.subjectLambert‐Eaton syndromeen_US
dc.titleValidation of the triple timed up‐and‐go test in Lambert‐Eaton myastheniaen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Raja_2019_validation.pdf
Size:
357.94 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: