Utilization of Cell-Transfer Technique for Molecular Testing on H&E-stained Sections- A Viable Option for Small Biopsies that Lack Tumor Tissues in Paraffin Block

If you need an accessible version of this item, please email your request to digschol@iu.edu so that they may create one and provide it to you.
Date
2016-12
Language
English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Abstract

Context.— In some instances the standard method of doing molecular testing from formalin-fixed, paraffin-embedded block is not possible because of limited tissue. Tumor cell–enriched cell-transfer technique has been proven useful for performing immunocytochemistry and molecular testing on cytologic smears.

Objective.— To establish the cell-transfer technique as a viable option for isolating tumor cells from hematoxylin-eosin (H&E)–stained slides.

Design.— Molecular testing was performed by using the cell-transfer technique on 97 archived H&E-stained slides from a variety of different tumors. Results were compared to the conventional method of molecular testing.

Results.— Polymerase chain reaction–based molecular testing via the cell-transfer technique was successfully performed on 82 of 97 samples (85%). This included 39 of 47 cases for EGFR, 10 of 11 cases for BRAF, and 33 of 39 cases for KRAS mutations. Eighty-one of 82 cell-transfer technique samples (99%) showed agreement with previous standard method results, including 4 mutations and 35 wild-type alleles for EGFR, 4 mutations and 6 wild-type alleles for BRAF, and 11 mutations and 21 wild-type alleles for KRAS. There was only 1 discrepancy: a cell-transfer technique with a false-negative >KRAS result (wild type versus G12C).

Conclusions.— Molecular testing performed on H&E-stained sections via cell-transfer technique is useful when tissue from cell blocks and small surgical biopsy samples is exhausted and the only available material for testing is on H&E-stained slides.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Wu, H. H., Jovonovich, S. M., Randolph, M., Post, K. M., Sen, J. D., Curless, K., & Cheng, L. (2016). Utilization of Cell-Transfer Technique for Molecular Testing on Hematoxylin-Eosin–Stained Sections: A Viable Option for Small Biopsies That Lack Tumor Tissues in Paraffin Block. Archives of Pathology & Laboratory Medicine, 140(12), 1383–1389. https://doi.org/10.5858/arpa.2015-0454-OA
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Archives of Pathology & Laboratory Medicine
Source
Author
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}