Evaluating the Reproducibility of Mouse Anatomy under Rotation in a Custom Immobilization Device for Conformal FLASH Radiotherapy

dc.contributor.authorKo, Ryan B.
dc.contributor.authorSoto, Luis A.
dc.contributor.authorvon Eyben, Rie
dc.contributor.authorMelemenidis, Stavros
dc.contributor.authorRankin, Erinn B.
dc.contributor.authorMaxim, Peter G.
dc.contributor.authorGraves, Edward E.
dc.contributor.authorLoo, Billy W., Jr.
dc.contributor.departmentRadiation Oncology, School of Medicineen_US
dc.date.accessioned2022-05-19T18:36:31Z
dc.date.available2022-05-19T18:36:31Z
dc.date.issued2020-12-01
dc.description.abstractThe observation of an enhanced therapeutic index for FLASH radiotherapy in mice has created interest in practical laboratory-based FLASH irradiators. To date, systems capable of 3D conformal FLASH irradiation in mice have been lacking. We are developing such a system, incorporating a high-current linear accelerator to produce a collimated X-ray beam in a stationary beamline design, rotating the mouse about a longitudinal axis to achieve conformal irradiation from multiple beam directions. The purpose of this work was to evaluate the reproducibility of mouse anatomy under rotation at speeds compatible with conformal FLASH delivery. Three short-hair mice and two hairless mice were immobilized under anesthesia in body weight-specific contoured plastic molds, and subjected to three rotational (up to 3 revolutions/s) and two non-rotational movement interventions. MicroCT images were acquired before and after each intervention. The displacements of 11 anatomic landmarks were measured on the image pairs. The displacement of the anatomical landmarks with any of the interventions was 0.5 mm or less for 92.4% of measurements, with a single measurement out of 275 (11 landmarks × 5 interventions × 5 mice) reaching 1 mm. There was no significant difference in the displacements associated with rotation compared to those associated with moving the immobilized mouse in and out of a scanner or with leaving the mouse in place for 5 min with no motion. There were no significant differences in displacements between mice with or without hair, although the analysis is limited by small numbers, or between different anatomic landmarks. These results show that anatomic reproducibility under rotation speed corresponding to FLASH irradiation times appears to be compatible with conformal/stereotactic irradiation in mice.en_US
dc.eprint.versionAuthor's manuscripten_US
dc.identifier.citationKo RB, Soto LA, von Eyben R, et al. Evaluating the Reproducibility of Mouse Anatomy under Rotation in a Custom Immobilization Device for Conformal FLASH Radiotherapy. Radiat Res. 2020;194(6):600-606. doi:10.1667/RADE-20-00095en_US
dc.identifier.urihttps://hdl.handle.net/1805/29090
dc.language.isoen_USen_US
dc.publisherBioOneen_US
dc.relation.isversionof10.1667/RADE-20-00095en_US
dc.relation.journalRadiation Researchen_US
dc.rightsPublisher Policyen_US
dc.sourcePMCen_US
dc.subjectMice, Inbred C57BLen_US
dc.subjectRadiotherapy, Conformalen_US
dc.subjectPhantoms, Imagingen_US
dc.titleEvaluating the Reproducibility of Mouse Anatomy under Rotation in a Custom Immobilization Device for Conformal FLASH Radiotherapyen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
nihms-1657026.pdf
Size:
1.28 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: