- Browse by Subject
Browsing by Subject "prosthesis"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item 3D Printing of Human Ossicle Models for the Biofabrication of Personalized Middle Ear Prostheses(MDPI, 2022-10-31) Dairaghi, Jacob; Rogozea, Dan; Cadle, Rachel; Bustamante, Joseph; Moldovan, Leni; Petrache, Horia I.; Moldovan, Nicanor I.; Physics, School of ScienceThe middle ear bones (‘ossicles’) may become severely damaged due to accidents or to diseases. In these situations, the most common current treatments include replacing them with cadaver-derived ossicles, using a metal (usually titanium) prosthesis, or introducing bridges made of biocompatible ceramics. Neither of these solutions is ideal, due to the difficulty in finding or producing shape-matching replacements. However, the advent of additive manufacturing applications to biomedical problems has created the possibility of 3D-printing anatomically correct, shape- and size-personalized ossicle prostheses. To demonstrate this concept, we generated and printed several models of ossicles, as solid, porous, or soft material structures. These models were first printed with a plottable calcium phosphate/hydroxyapatite paste by extrusion on a solid support or embedded in a Carbopol hydrogel bath, followed by temperature-induced hardening. We then also printed an ossicle model with this ceramic in a porous format, followed by loading and crosslinking an alginate hydrogel within the pores, which was validated by microCT imaging. Finally, ossicle models were printed using alginate as well as a cell-containing nanocellulose-based bioink, within the supporting hydrogel bath. In selected cases, the devised workflow and the printouts were tested for repeatability. In conclusion, we demonstrate that moving beyond simplistic geometric bridges to anatomically realistic constructs is possible by 3D printing with various biocompatible materials and hydrogels, thus opening the way towards the in vitro generation of personalized middle ear prostheses for implantation.Item Vibratory Stimulus Reduces In Vitro Biofilm Formation On Tracheoesophageal Voice Prostheses(Wiley, 2016) Wannemuehler, Todd J.; Lobo, Brian C.; Johnson, Jeffrey D.; Deig, Christopher R.; Ting, Jonathan Y.; Gregory, Richard L.; Department of Otolaryngology--Head and Neck Surgery, IU School of MedicineObjectives/Hypothesis Demonstrate that biofilm formation will be reduced on tracheoesophageal prostheses when vibratory stimulus is applied, compared to controls receiving no vibratory stimulus, in a dynamic in vitro model of biofilm accumulation simulating the interface across the tracheoesophageal puncture site. Study Design Prospective, randomized, controlled, crossover in university laboratory. Methods Ex vivo tracheoesophageal prostheses were obtained from university-affiliated speech language pathologists at Indiana University School of Medicine, Indianapolis. Prostheses demonstrating physical integrity and an absence of gross biofilm accumulation were utilized. Sixteen prostheses were cleansed and sterilized prior to random placement by length in two modified Robbins devices arranged in parallel. Each device was seeded with a polymicrobial oral flora on day 1 and received basal artificial salivary flow continuously with three growth medium meals daily. One device was randomly selected for vibratory stimulus, and 2 minutes of vibration was applied to each prosthesis before and after meals for 5 days. The prostheses were explanted and sonicated, and the biofilm cultured for enumeration. This process was repeated after study arm crossover. Results Tracheoesophageal prostheses in the dynamic model receiving vibratory stimulus demonstrated reduced gross biofilm accumulation and a significant biofilm colony forming unit per milliliter reduction of 5.56-fold compared to nonvibratory controls (P < 0.001). Significant reductions were observed within length subgroups. Conclusion Application of vibratory stimulus around meal times significantly reduces biofilm accumulation on tracheoesophageal prostheses in a dynamic in vitro model. Further research using this vibratory stimulus method in vivo will be required to determine if reduced biofilm accumulation correlates with longer device lifespan.