    Characterization of the Electrical Properties of Mammalian Peripheral Nerve Laminae
    (Wiley, 2023) Horn, M. Ryne; Vetter, Christian; Bashirullah, Rizwan; Carr, Mike; Yoshida, Ken; Biomedical Engineering, School of Engineering and Technology
    Background and objective: The intrinsic electrical material properties of the laminar components of the mammalian peripheral nerve bundle are important parameters necessary for the accurate simulation of the electrical interaction between nerve fibers and neural interfaces. Improvements in the accuracy of these parameters improve the realism of the simulation and enables realistic screening of novel devices used for extracellular recording and stimulation of mammalian peripheral nerves. This work aims to characterize these properties for mammalian peripheral nerves to build upon the resistive parameter set established by Weerasuriya et al. in 1984 for amphibian somatic peripheral nerves (frog sciatic nerve) that is currently used ubiquitously in the in-silico peripheral nerve modeling community. Methods: A custom designed characterization chamber was implemented and used to measure the radial and longitudinal impedance between 10 mHz and 50 kHz of freshly excised canine vagus nerves using four-point impedance spectroscopy. The impedance spectra were parametrically fitted to an equivalent circuit model to decompose and estimate the components of the various laminae. Histological sections of the electrically characterized nerves were then made to quantify the geometry and laminae thicknesses of the perineurium and epineurium. These measured values were then used to calculate the estimated intrinsic electrical properties, resistivity and permittivity, from the decomposed resistances and reactances. Finally, the estimated intrinsic electrical properties were used in a finite element method (FEM) model of the nerve characterization setup to evaluate the realism of the model. Results: The geometric measurements were as follows: nerve bundle (1.6 ± 0.6 mm), major nerve fascicle diameter (1.3 ± 0.23 mm), and perineurium thickness (13.8 ± 2.1 μm). The longitudinal resistivity of the endoneurium was estimated to be 0.97 ± 0.05 Ωm. The relative permittivity and resistivity of the perineurium were estimated to be 2018 ± 391 and 3.75 kΩm ± 981 Ωm, respectively. The relative permittivity and resistivity of the epineurium were found to be 9.4 × 106 ± 8.2 × 106 and 55.0 ± 24.4 Ωm, respectively. The root mean squared (RMS) error of the experimentally obtained values when used in the equivalent circuit model to determine goodness of fit against the measured impedance spectra was found to be 13.0 ± 10.7 Ω, 2.4° ± 1.3°. The corner frequency of the perineurium and epineurium were found to be 2.6 ± 1.0 kHz and 368.5 ± 761.9 Hz, respectively. A comparison between the FEM model in-silico impedance experiment against the ex-vivo methods had a RMS error of 159.0 ± 95.4 Ω, 20.7° ± 9.8°. Conclusion: Although the resistive values measured in the mammalian nerve are similar to those of the amphibian model, the relative permittivity of the laminae bring new information about the reactance and the corner frequency (frequency at peak reactance) of the peripheral nerve. The measured and estimated corner frequency are well within the range of most bioelectric signals, and are important to take into account when modeling the nerve and neural interfaces.
  • Loading...
    Thumbnail Image
    Item
    Durable scalable 3D SLA-printed cuff electrodes with high performance carbon + PEDOT:PSS-based contacts
    (Wiley, 2022) Doering, Onna Marie; Vetter, Christian; Alhawwash, Awadh; Horn, M. Ryne; Yoshida, Ken; Biomedical Engineering, School of Engineering and Technology
    Background: The stimulation and recording performance of implanted neural interfaces are functions of the physical and electrical characteristics of the neural interface, its electrode material and structure. Therefore, rapid optimization of such characteristics is becoming critical in most clinical and research studies. This paper describes the development of an upgraded 3D printed cuff electrode shell design containing a novel intrinsically conductive polymer (ICP) for stimulation and recording of peripheral nerve fibers. Methods: A 3D stereolithography (SLA) printer was used to print a scalable, custom designed, C-cuff electrode and I-beam closure for accurate, rapid implementation. A novel contact consisting of a percolated carbon graphite base electrodeposited with an intrinsically conductive polymer (ICP), poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) produced a PEDOT:PSS + carbon black (CB) matrix that was used to form the electrochemical interface on the structure. Prototype device performance was tested both in-vitro and in-vivo for electrical chemical capacity, electrochemical interfacial impedance, surgical handling, and implantability. The in-vivo work was performed on the sciatic nerve of 25 anesthetized Sprague Dawley rats to demonstrate recording and stimulating ability. Results: Prototypes of different spatial geometries and number of contacts (bipolar, tripolar, and tetrapolar) were designed. The design was successfully printed with inner diameters down to 500 μm. Standard bipolar and tripolar cuffs, with a 1.3 mm inner diameter (ID), 0.5 mm contact width, 1.0 mm pitch, and a 1.5 mm end distance were used for the functional tests. This geometry was appropriate for placement on the rat sciatic nerve and enabled in-vivo testing in anesthetized rats. The contacts on the standard bipolar electrode had an area of 2.1 × 10-2 cm2 . Cyclic voltammetry on ICP coated and uncoated graphite contacts showed that the ICP increased the average charge storage capacity (CSC) by a factor of 30. The corresponding impedance at 1 Hz was slightly above 1 kΩ, a 99.99% decrease from 100 kΩ in the uncoated state. The statistical comparison of the pre- versus post-stimulation impedance measurements were not significantly different (p-value > 0.05). Conclusions: The new cuff electrode enables rapid development of cost-effective functional stimulation devices targeting nerve bundles less than 1.0 mm in diameter. This allows for recording and modulation of a low-frequency current targeted within the peripheral nervous system.
  • Loading...
    Thumbnail Image
    Item
    In vivo peripheral nerve activation using sinusoidal low-frequency alternating currents
    (Wiley, 2022) Alhawwash, Awadh; Muzquiz, M. Ivette; Richardson, Lindsay; Vetter, Christian; Smolik, Macallister; Goodwill, Adam; Yoshida, Ken; Biomedical Engineering, School of Engineering and Technology
    Background: The sinusoidal low-frequency alternating current (LFAC) waveform was explored recently as a novel means to evoke nerve conduction block. In the present work, we explored whether increasing the amplitude of the LFAC waveform results in nerve fiber activation in autonomic nerves. In-silico methods and preliminary work in somatic nerves indicated a potential frequency dependency on the threshold of activation. The Hering-Breuer (HB) reflex was used as a biomarker to detect cervical vagus nerve activation. Methods: Experiments were conducted in isoflurane-anesthetized swine (n = 5). Two stimulating bipolar cuff electrodes and a tripolar recording cuff electrode were implanted on the left vagus nerve. To ensure the electrical stimulation affects only the afferent pathways, the nerve was crushed caudal to the electrodes to eliminate cardiac effects. (1) Standard pulse stimulation (Vstim) using a monophasic train of pulses was applied through the caudal electrode to elicit HB reflex and to identify the activated nerve fiber type. (2) Continuous sinusoidal LFAC waveform with a frequency ranging from 5 through 20 Hz was applied to the rostral electrode without Vstim to explore the activation thresholds at each LFAC frequency. In both cases, the activation of nerve fibers was detected by a HB reflex-induced reduction in the breathing rate. Results: LFAC was found to be capable of eliciting an HB response. The LFAC activation thresholds were found to be frequency-dependent. The HB threshold was 1.02 ± 0.3 mAp at 5 Hz, 0.66 ± 0.3 mAp at 10 Hz, and 0.44 ± 0.2 mAp at 20 Hz. In comparison, it was 0.7 ± 0.47 mA for a 100 μs pulse. The LFAC amplitude was within the linear limits of the electrode interface. Damage to the cuff electrodes or the nerve tissues was not observed. Analysis of Vstim-based compound nerve action potentials (CNAP) indicated that the decrease in breathing rate was found to be correlated with the activation of slower components of the CNAP suggesting that LFAC reached and elicited responses from these slower fibers associated with afferents projecting to the HB response. Conclusions: These results suggest the feasibility of the LFAC waveform at 5, 10, and 20 Hz to activate autonomic nerve fibers and potentially provide a new modality to the neurorehabilitation field.
  • Loading...
    Thumbnail Image
    Item
    In-vivo application of low frequency alternating currents on porcine cervical vagus nerve evokes reversible nerve conduction block
    (BMC, 2021-06-30) Muzquiz, Maria Ivette; Richardson, Lindsay; Vetter, Christian; Smolik, Macallister; Alhawwash, Awadh; Goodwill, Adam; Bashirullah, Rizwan; Carr, Michael; Yoshida, Ken; Biomedical Engineering, School of Engineering and Technology
    Background: This paper describes a method to reversibly block nerve conduction through direct application of a 1 Hz sinusoidal current waveform delivered through a bipolar nerve cuff electrode. This low frequency alternating current (LFAC) waveform was previously shown to reversibly block the effects of vagal pulse stimulation evoked bradycardia in-vivo in the anaesthetised rat model (Mintch et al. 2019). The present work measured the effectiveness of LFAC block on larger caliber myelinated vagal afferent fibers in human sized nerve bundles projecting to changes in breathing rate mediated by the Hering-Breuer (HB) reflex in anaesthetized domestic swine (n=5). Methods: Two bipolar cuff electrodes were implanted unilaterally to the left cervical vagus nerve, which was crushed caudal to the electrodes to eliminate cardiac effects. A tripolar recording cuff electrode was placed rostral to the bipolar stimulating electrodes on the same nerve to measure changes in the compound nerve action potentials (CNAP) elicited by the vagal pulse stimulation and conditioned by the LFAC waveform. Standard pulse stimulation was applied at a sufficient level to induce a reduction in breathing rate through the HB reflex. If unblocked, the HB reflex would cause breathing to slow down and potentially halt completely. Block was quantified by the ability of LFAC to reduce the effect of the HB reflex by monitoring the respiration rate during LFAC alone, LFAC and vagal stimulation, and vagal stimulation alone. Results: LFAC achieved 87.2 ±8.8% block (n=5) at current levels of 1.1 ±0.3 mAp (current to peak), which was well within the water window of the working electrode. CNAP showed changes that directly correlated to the effectiveness of LFAC block, which manifested itself as the slowing and amplitude reduction of components of the CNAP. Conclusion: These novel findings suggest that LFAC is a potential alternative or complementary method to other electrical blocking techniques in clinical applications.