- Browse by Author
Browsing by Author "Totten, Douglas J."
Now showing 1 - 4 of 4
Results Per Page
Sort Options
Item Cochlear Implantation in US Military Veterans: A Single Institution Study(Sage, 2023-05-12) Totten, Douglas J.; Saltagi, Abdul; Libich, Karen; Pisoni, David B.; Nelson, Rick F.; Otolaryngology -- Head and Neck Surgery, School of MedicineObjective: Military veterans have high rates of noise-induced hearing loss (NIHL) which is associated with more significant spiral ganglion neuronal loss. This study explores the relationship between NIHL and cochlear implant (CI) outcomes in veterans. Study design: Retrospective case series of veterans who underwent CI between 2019 and 2021. Setting: Veterans Health Administration hospital. Methods: AzBio Sentence Test, Consonant-Nucleus-Consonant (CNC) scores, and Speech, Spatial, and Qualities of Hearing Scale (SSQ) were measured pre- and postoperatively. Linear regression assessed relationships between outcomes and noise exposure history, etiology of hearing loss, duration of hearing loss, and Self-Administered Gerocognitive Exam (SAGE) scores. Results: Fifty-two male veterans were implanted at an average (standard deviation) age of 75.0 (9.2) years without major complications. The average duration of hearing loss was 36.0 (18.4) years. The average time of hearing aid use was 21.2 (15.4) years. Noise exposure was reported in 51.3% of patients. Objectively, AzBio and CNC scores 6 months postoperatively showed significant improvement of 48% and 39%, respectively. Subjectively, average 6-month SSQ scores showed significant improvement by 34 points (p < .0001). Younger age, SAGE score ≥17, and shorter duration of amplification were associated with higher postoperative AzBio scores. Greater improvement in AzBio and CNC scores was associated with lower preoperative scores. Noise exposure was not associated with any difference in CI performance. Conclusion: Despite high levels of noise exposure and advanced age, veterans derive substantial benefits from cochlear implantation. SAGE score ≥17 may be predictive of overall CI outcomes. Noise exposure does not impact CI outcomes.Item Speech Recognition Outcomes in Adults With Slim Straight and Slim Modiolar Cochlear Implant Electrode Arrays(Springer, 2022-05) MacPhail, Margaret E.; Connell, Nathan T.; Totten, Douglas J.; Gray, Mitchell T.; Pisoni, David; Yates, Charles W.; Nelson, Rick F.; Otolaryngology -- Head and Neck Surgery, School of MedicineObjective To compare differences in audiologic outcomes between slim modiolar electrode (SME) CI532 and slim lateral wall electrode (SLW) CI522 cochlear implant recipients. Study Design Retrospective cohort study. Setting Tertiary academic hospital. Methods Comparison of postoperative AzBio sentence scores in quiet (percentage correct) in adult cochlear implant recipients with SME or SLW matched for preoperative AzBio sentence scores in quiet and aided and unaided pure tone average. Results Patients with SLW (n = 52) and patients with SME (n = 37) had a similar mean (SD) age (62.0 [18.2] vs 62.6 [14.6] years, respectively), mean preoperative aided pure tone average (55.9 [20.4] vs 58.1 [16.4] dB; P = .59), and mean AzBio score (percentage correct, 11.1% [13.3%] vs 8.0% [11.5%]; P = .25). At last follow-up (SLW vs SME, 9.0 [2.9] vs 9.9 [2.6] months), postoperative mean AzBio scores in quiet were not significantly different (percentage correct, 70.8% [21.3%] vs 65.6% [24.5%]; P = .29), and data log usage was similar (12.9 [4.0] vs 11.3 [4.1] hours; P = .07). In patients with preoperative AzBio <10% correct, the 6-month mean AzBio scores were significantly better with SLW than SME (percentage correct, 70.6% [22.9%] vs 53.9% [30.3%]; P = .02). The intraoperative tip rollover rate was 8% for SME and 0% for SLW. Conclusions Cochlear implantation with SLW and SME provides comparable improvement in audiologic functioning. SME does not exhibit superior speech recognition outcomes when compared with SLW.Item TMPRSS3 expression is limited in spiral ganglion neurons: implication for successful cochlear implantation(BMJ, 2022) Chen, Yuan-Siao; Cabrera, Ernesto; Tucker, Brady J.; Shin, Timothy J.; Moawad, Jasmine V.; Totten, Douglas J.; Booth, Kevin T.; Nelson, Rick F.; Otolaryngology -- Head and Neck Surgery, School of MedicineBackground: It is well established that biallelic mutations in transmembrane protease, serine 3 (TMPRSS3) cause hearing loss. Currently, there is controversy regarding the audiological outcomes after cochlear implantation (CI) for TMPRSS3-associated hearing loss. This controversy creates confusion among healthcare providers regarding the best treatment options for individuals with TMPRSS3-related hearing loss. Methods: A literature review was performed to identify all published cases of patients with TMPRSS3-associated hearing loss who received a CI. CI outcomes of this cohort were compared with published adult CI cohorts using postoperative consonant-nucleus-consonant (CNC) word performance. TMPRSS3 expression in mouse cochlea and human auditory nerves (HAN) was determined by using hybridisation chain reaction and single-cell RNA-sequencing analysis. Results: In aggregate, 27 patients (30 total CI ears) with TMPRSS3-associated hearing loss treated with CI, and 85% of patients reported favourable outcomes. Postoperative CNC word scores in patients with TMPRSS3-associated hearing loss were not significantly different than those seen in adult CI cohorts (8 studies). Robust Tmprss3 expression occurs throughout the mouse organ of Corti, the spindle and root cells of the lateral wall and faint staining within <5% of the HAN, representing type II spiral ganglion neurons. Adult HAN express negligible levels of TMPRSS3. Conclusion: The clinical features after CI and physiological expression of TMPRSS3 suggest against a major role of TMPRSS3 in auditory neurons.Item Trends in Spontaneous Cerebrospinal Fluid Leak Repairs in the United States, 2009-2018(Wolters Kluwer, 2022-10-27) Totten, Douglas J.; Schueth, Elizabeth; Saltagi, Mohamad Z.; Rabbani, Cyrus; Hartsell Harris, Alyssa; Tressman, Dani; Hohmann, Samuel F.; Nelson, Rick F.; Otolaryngology -- Head and Neck Surgery, School of MedicineBackground: Rates of spontaneous cerebrospinal fluid leak (sCSF) repairs have increased in recent decades in line with increases in obesity rates. Objectives: To determine if the national rate of sCSF leak has continued to rise in recent years and to identify associated risk factors utilizing a comprehensive national database comprising most academic medical centers. Methods: A retrospective review from 2009 to 2018 was performed using the Vizient Clinical Database (CDB) of 105 leading academic medical centers in the United States. Patients who underwent CSF leak repair in the CDB database using ICD-9 and ICD-10 diagnostic and procedure codes. Patients with epidural hematomas over the same time frame were used as a control. National rates of craniotomy for sCSF leak repair each quarter were assessed and sCSF leak patient characteristics (age, gender, obesity, hypertension, diabetes) were calculated. Results: The rate of craniotomy for all sCSF leak repairs increased by 10.2% annually from 2009 to 2015 (P < 0.0001). There was no statistically significant change in the rate of epidural hematomas over the same period. The rate of lateral sCSF leak repair increased on average by 10.4% annually from 2009 (218 cases/year) to 2018 (457 cases/year) (P < 0.0001). A statistically significant increase was observed across all regions of the United States (P ≤ 0.005). sCSF leak patients had an average (standard deviation) age of 55.0 (13.2) years and 67.2% were female. Obesity was the only demographic factors that increased significantly over time. Likely due to comorbid factors, Black patients comprise a disproportionately large percentage of lateral sCSF leak repair patients. Conclusions: The rate of craniotomy for spontaneous CSF leaks continues to rise by approximately 10% annually.