- Browse by Author
Browsing by Author "Smith, Lester"
Now showing 1 - 3 of 3
Results Per Page
Sort Options
Item Oxygenation Profiles of Human Blood, Cell Culture Medium, and Water for Perfusion of 3D-Bioprinted Tissues using the FABRICA Bioreactor Platform(Nature Research, 2020-04-29) Chen, Angela M.; Lashmet, Matthew; Isidan, Abdulkadir; Sterner, Jane L.; Walsh, Julia; Koehler, Cutter; Li, Ping; Ekser, Burcin; Smith, Lester; Surgery, School of MedicinePersistent and saturated oxygen distribution from perfusion media (i.e., blood, or cell culture media) to cells within cell-dense, metabolically-active biofabricated tissues is required to keep them viable. Improper or poor oxygen supply to cells within the tissue bulk severely limits the tissue culturing potential of many bioreactors. We added an oxygenator module to our modular FABRICA bioreactor in order to provide stable oxygenation to biofabricated tissues during culture. In this proof of concept study of an oxygenated and perfused bioreactor, we characterized the oxygenation of water, cell culture medium, and human blood in the FABRICA as functions of augmenting vacuum (air inlet) pressure, perfusion (volumetric flow) rate, and tubing/oxygenator components. The mean oxygen levels for water and cell culture media were 27.7 ± 2.1% and 27.6 ± 4.1%, respectively. The mean oxygen level for human blood was 197.0 ± 90.0 mmHg, with near-physiologic levels achieved with low-permeability PharMed tubing alone (128.0 ± 14.0 mmHg). Hematologic values pre- and post-oxygenation, respectively were (median ± IQR): Red blood cell: 6.0 ± 0.5 (106/μL) and 6.5 ± 0.4 (106/μL); Hemoglobin: 17.5 ± 1.2 g/dL and 19.2 ± 3.0 g/dL; and Hematocrit: 56.7 ± 2.4% and 61.4 ± 7.5%. The relative stability of the hematologic parameters indicates that blood function and thus blood cell integrity were maintained throughout oxygenation. Already a versatile research tool, the now oxygenated FABRICA provides easy-to-implement, in vivo-like perfusion and stable oxygenation culture conditions in vitro semi-independently of one another, which means the bioreactor has the potential to serve as a platform for investigating the behavior of 3D tissue models (regardless of biofabrication method), performing drug toxicity-testing, and testing pharmaceutical efficacy/safety.Item Oxygenation Profiles of Human Blood, Cell Culture Medium, and Water for Perfusion of 3D-Bioprinted Tissues using the FABRICA Bioreactor Platform(Nature, 2020-04-29) Chen, Angela M.; Lashmet, Matthew; Isidan, Abdulkadir; Sterner, Jane L.; Walsh, Julia; Koehler, Cutter; Li, Ping; Ekser, Burcin; Smith, Lester; Surgery, School of MedicinePersistent and saturated oxygen distribution from perfusion media (i.e., blood, or cell culture media) to cells within cell-dense, metabolically-active biofabricated tissues is required to keep them viable. Improper or poor oxygen supply to cells within the tissue bulk severely limits the tissue culturing potential of many bioreactors. We added an oxygenator module to our modular FABRICA bioreactor in order to provide stable oxygenation to biofabricated tissues during culture. In this proof of concept study of an oxygenated and perfused bioreactor, we characterized the oxygenation of water, cell culture medium, and human blood in the FABRICA as functions of augmenting vacuum (air inlet) pressure, perfusion (volumetric flow) rate, and tubing/oxygenator components. The mean oxygen levels for water and cell culture media were 27.7 ± 2.1% and 27.6 ± 4.1%, respectively. The mean oxygen level for human blood was 197.0 ± 90.0 mmHg, with near-physiologic levels achieved with low-permeability PharMed tubing alone (128.0 ± 14.0 mmHg). Hematologic values pre- and post-oxygenation, respectively were (median ± IQR): Red blood cell: 6.0 ± 0.5 (106/μL) and 6.5 ± 0.4 (106/μL); Hemoglobin: 17.5 ± 1.2 g/dL and 19.2 ± 3.0 g/dL; and Hematocrit: 56.7 ± 2.4% and 61.4 ± 7.5%. The relative stability of the hematologic parameters indicates that blood function and thus blood cell integrity were maintained throughout oxygenation. Already a versatile research tool, the now oxygenated FABRICA provides easy-to-implement, in vivo-like perfusion and stable oxygenation culture conditions in vitro semi-independently of one another, which means the bioreactor has the potential to serve as a platform for investigating the behavior of 3D tissue models (regardless of biofabrication method), performing drug toxicity-testing, and testing pharmaceutical efficacy/safety.Item The 'bIUreactor': An Open-Source 3D Tissue Research Platform(Springer, 2024) Butch, Elizabeth; Prideaux, Matthew; Holland, Mark; Phan, Justin‑Thuy; Trent, Cole; Soon, Victor; Hutchins, Gary; Smith, Lester; Radiology and Imaging Sciences, School of MedicineWe developed the open-source bIUreactor research platform for studying 3D structured tissues. The versatile and modular platform allows a researcher to generate 3D tissues, culture them with oxygenated perfusion, and provide cyclic loading, all in their own lab (in laboratorium) for an all in cost of $8,000 including 3D printer, printing resin, and electronics. We achieved this by applying a design philosophy that leverages 3D printing, open-source software and hardware, and practical techniques to produce the following: 1. perfusible 3D tissues, 2. a bioreactor chamber for tissue culture, 3. a module for applying cyclic compression, 4. a peristaltic pump for providing oxygenated perfusion to 3D tissues, 5. motor control units, and 6. open-source code for running the control units. By making it widely available for researchers to investigate 3D tissue models and easy for them to use, we intend for the bIUreactor to democratize 3D tissue research, therefore increasing the pace and scale of biomedical research discoveries using 3D tissue models.