- Browse by Author
Browsing by Author "Huang, Yuheng"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Accurate Intramyocardial Hemorrhage Assessment with Fast, Free-running, Cardiac Quantitative Susceptibility Mapping(Radiological Society of North America, 2024) Huang, Yuheng; Guan, Xingmin; Zhang, Xinheng; Yoosefian, Ghazal; Ho, Hao; Huang, Li-Ting; Lin, Hsin-Yao; Anthony, Gregory; Lee, Hsu-Lei; Bi, Xiaoming; Han, Fei; Chan, Shing Fai; Vora, Keyur P.; Sharif, Behzad; Singh, Dhirendra P.; Youssef, Khalid; Li, Debiao; Han, Hui; Christodoulou, Anthony G.; Dharmakumar, Rohan; Yang, Hsin-Jung; Medicine, School of MedicinePurpose: To evaluate the performance of a high-dynamic-range quantitative susceptibility mapping (HDR-QSM) cardiac MRI technique to detect intramyocardial hemorrhage (IMH) and quantify iron content using phantom and canine models. Materials and Methods: A free-running whole-heart HDR-QSM technique for IMH assessment was developed and evaluated in calibrated iron phantoms and 14 IMH female canine models. IMH detection and iron content quantification performance of this technique was compared with the conventional iron imaging approaches, R2*(1/T2*) maps, using measurements from ex vivo imaging as the reference standard. Results: Phantom studies confirmed HDR-QSM’s accurate iron content quantification and artifact mitigation ability by revealing a strong linear relationship between iron concentration and QSM values (R2, 0.98). In in vivo studies, HDR-QSM showed significantly improved image quality and susceptibility homogeneity in nonaffected myocardium by alleviating motion and off-resonance artifacts (HDR-QSM vs R2*: coefficient of variation, 0.31 ± 0.16 [SD] vs 0.73 ± 0.36 [P < .001]; image quality score [five-point Likert scale:], 3.58 ± 0.75 vs 2.87 ± 0.51 [P < .001]). Comparison between in vivo susceptibility maps and ex vivo measurements showed higher performance of HDR-QSM compared with R2* mapping for IMH detection (area under the receiver operating characteristic curve, 0.96 vs 0.75; P < .001) and iron content quantification (R2, 0.71 vs 0.14). Conclusion: In a canine model of IMH, the fast and free-running cardiac QSM technique accurately detected IMH and quantified intramyocardial iron content of the entire heart within 5 minutes without requiring breath holding.Item Reliable Off-Resonance Correction in High-Field Cardiac MRI Using Autonomous Cardiac B0 Segmentation with Dual-Modality Deep Neural Networks(MDPI, 2024-02-23) Li, Xinqi; Huang, Yuheng; Malagi, Archana; Yang, Chia-Chi; Yoosefian, Ghazal; Huang, Li-Ting; Tang, Eric; Gao, Chang; Han, Fei; Bi, Xiaoming; Ku, Min-Chi; Yang, Hsin-Jung; Han, Hui; Medicine, School of MedicineB0 field inhomogeneity is a long-lasting issue for Cardiac MRI (CMR) in high-field (3T and above) scanners. The inhomogeneous B0 fields can lead to corrupted image quality, prolonged scan time, and false diagnosis. B0 shimming is the most straightforward way to improve the B0 homogeneity. However, today’s standard cardiac shimming protocol requires manual selection of a shim volume, which often falsely includes regions with large B0 deviation (e.g., liver, fat, and chest wall). The flawed shim field compromises the reliability of high-field CMR protocols, which significantly reduces the scan efficiency and hinders its wider clinical adoption. This study aims to develop a dual-channel deep learning model that can reliably contour the cardiac region for B0 shim without human interaction and under variable imaging protocols. By utilizing both the magnitude and phase information, the model achieved a high segmentation accuracy in the B0 field maps compared to the conventional single-channel methods (Dice score: 2D-mag = 0.866, 3D-mag = 0.907, and 3D-mag-phase = 0.938, all p < 0.05). Furthermore, it shows better generalizability against the common variations in MRI imaging parameters and enables significantly improved B0 shim compared to the standard method (SD(B0Shim): Proposed = 15 ± 11% vs. Standard = 6 ± 12%, p < 0.05). The proposed autonomous model can boost the reliability of cardiac shimming at 3T and serve as the foundation for more reliable and efficient high-field CMR imaging in clinical routines.