- Browse by Author
Browsing by Author "Giridharan, Guruprasad A."
Now showing 1 - 3 of 3
Results Per Page
Sort Options
Item Cavopulmonary assist for the failing Fontan circulation: impact of ventricular function on mechanical support strategy(Ovid Technologies (Wolters Kluwer) - Lippincott Williams & Wilkins, 2014-11) Giridharan, Guruprasad A.; Ising, Mickey; Sobieski, Michael A.; Koenig, Steven C.; Chen, Jun; Frankel, Steven C.; Rodefeld, Mark D.; Department of Surgery, IU School of MedicineMechanical circulatory support--either ventricular assist device (VAD, left-sided systemic support) or cavopulmonary assist device (CPAD, right-sided support)--has been suggested as treatment for Fontan failure. The selection of left- versus right-sided support for failing Fontan has not been previously defined. Computer simulation and mock circulation models of pediatric Fontan patients (15-25 kg) with diastolic, systolic, and combined systolic and diastolic dysfunction were developed. The global circulatory response to assisted Fontan flow using VAD (HeartWare HVAD, Miami Lakes, FL) support, CPAD (Viscous Impeller Pump, Indianapolis, IN) support, and combined VAD and CPAD support was evaluated. Cavopulmonary assist improves failing Fontan circulation during diastolic dysfunction but preserved systolic function. In the presence of systolic dysfunction and elevated ventricular end-diastolic pressure (VEDP), VAD support augments cardiac output and diminishes VEDP, while increased preload with cavopulmonary assist may worsen circulatory status. Fontan circulation can be stabilized to biventricular values with modest cavopulmonary assist during diastolic dysfunction. Systemic VAD support may be preferable to maintain systemic output during systolic dysfunction. Both systemic and cavopulmonary support may provide best outcome during combined systolic and diastolic dysfunction. These findings may be useful to guide clinical cavopulmonary assist strategies in failing Fontan circulations.Item Cavopulmonary assist: Long-term reversal of the Fontan paradox(Elsevier, 2019-12) Rodefeld, Mark D.; Marsden, Alison; Figliola, Richard; Jonas, Travis; Neary, Michael; Giridharan, Guruprasad A.; Surgery, School of MedicineObjective Fontan circulatory inefficiency can be addressed by replacing the missing subpulmonary power source to reverse the Fontan paradox. An implantable cavopulmonary assist device is described that will simultaneously reduce systemic venous pressure and increase pulmonary arterial pressure, improving preload and cardiac output, in a univentricular Fontan circulation on a long-term basis. Methods A rotary blood pump that was based on the von Karman viscous pump was designed for implantation into the total cavopulmonary connection (TCPC). It will impart modest pressure energy to augment Fontan flow without risk of obstruction. In the event of rotational failure, it is designed to default to a passive flow diverter. Pressure-flow performance was characterized in vitro in a Fontan mock circulatory loop with blood analog. Results The pump performed through the fully specified operating range, augmenting flow in all 4 directions of the TCPC. Pressure rise of 6 to 8 mm Hg was readily achieved, ranging to 14 mm Hg at highest speed (5600 rpm). Performance was consistent across a wide range of cardiac outputs. In stalled condition (0 rpm), there was no discernible pressure loss across the TCPC. Conclusions A blood pump technology is described that can reverse the Fontan paradox and may permit a surgical strategy of long-term biventricular maintenance of a univentricular Fontan circulation. The technology is intended for Fontan failure in which right-sided circulatory inefficiencies predominate and ventricular systolic function is preserved. It may also apply before clinical Fontan failure as health maintenance to preempt the progression of Fontan disease.Item Passive performance evaluation and validation of a viscous impeller pump for subpulmonary fontan circulatory support(Springer Nature, 2023-08-04) Yang, Weiguang; Conover, Timothy A.; Figliola, Richard S.; Giridharan, Guruprasad A.; Marsden, Alison L.; Rodefeld, Mark D.; Surgery, School of MedicinePatients with single ventricle defects undergoing the Fontan procedure eventually face Fontan failure. Long-term cavopulmonary assist devices using rotary pump technologies are currently being developed as a subpulmonary power source to prevent and treat Fontan failure. Low hydraulic resistance is a critical safety requirement in the event of pump failure (0 RPM) as a modest 2 mmHg cavopulmonary pressure drop can compromise patient hemodynamics. The goal of this study is therefore to assess the passive performance of a viscous impeller pump (VIP) we are developing for Fontan patients, and validate flow simulations against in-vitro data. Two different blade heights (1.09 mm vs 1.62 mm) and a blank housing model were tested using a mock circulatory loop (MCL) with cardiac output ranging from 3 to 11 L/min. Three-dimensional flow simulations were performed and compared against MCL data. In-silico and MCL results demonstrated a pressure drop of < 2 mmHg at a cardiac output of 7 L/min for both blade heights. There was good agreement between simulation and MCL results for pressure loss (mean difference − 0.23 mmHg 95% CI [0.24–0.71]). Compared to the blank housing model, low wall shear stress area and oscillatory shear index on the pump surface were low, and mean washout times were within 2 s. This study demonstrated the low resistance characteristic of current VIP designs in the failed condition that results in clinically acceptable minimal pressure loss without increased washout time as compared to a blank housing model under normal cardiac output in Fontan patients.