- Browse by Author
Browsing by Author "Cochran, Michael A. (Michael Alan), 1944-"
Now showing 1 - 10 of 15
Results Per Page
Sort Options
Item The effect of filler on the mechanical properties of a novel resin-based calcium phosphate cement(2010) Al Dehailan, Laila; Chu, Tien-Min Gabriel; Lund, Melvin R, 1922-; Cochran, Michael A. (Michael Alan), 1944-; Martinez Mier, Esperanza de los A. (Esperanza de los Angeles), 1967-; Cook, Norman Blaine, 1954-Several studies have found that resin-based amorphous calcium phosphate (ACP) composites can function well for applications that do not require high mechanical demand. Milled tricalcium phosphate (TCP), a new calcium-phosphate-releasing material, is crystalline in nature, suggesting it to be strong. In the present study, we investigated the use of a TCP-filled composite resin as a possible tooth restorative-material. An experimental TCP-based composite was prepared using monomer with a mixture of 34.3 percent by mass of EBPADMA, 34.2 percent by mass of HmDMA, and 30.5 percent by mass of HEMA. TCP fillers were added to the monomer mixture at different levels (30 percent, 40 percent, 50 percent, and 60 percent by weight). A universal testing machine (Sintech Renew 1121; Instron Engineering Corp., Canton, MA) was used to measure the compressive strength and modulus. FTIR was used to measure the degree of conversion. The depth of cure was determined according to the ISO standards for dental resin 4049 using the scrapping technique. Knoop hardness numbers were obtained by a microhardness tester (M-400; Leco Co., St. Joseph, MI). The viscosities of the experimental resin were determined in a viscometer (DV-II+ Viscometer; Brookfield, Middleboro, MA). The data were analyzed using a one-way analysis of variance (ANOVA). A 5-percent significance level was used for all the tests. Resin composites with 30-percent TCP filler showed the highest compressive strength and hardness values. Also, this group showed the lowest degree of conversion. Resin composites with 60-percent TCP filler showed the highest degree of conversion. However, this group showed the lowest compressive strength, depth of cure, and hardness. Resin composites with 50-percent filler showed the highest compressive modulus. Resin composites with 40-percent filler showed higher viscosity values than resin composites with 30-percent filler. In conclusion, increasing the filler level significantly reduced the compressive strength, hardness, and depth of cure, but increased the degree of conversion. Also, resin composites with the lowest filler level (30 percent) had the highest compressive strength, depth of cure, and hardness. From these results, it can be concluded that the experimental TCP-filled resin used in this study cannot be used as restorative material.Item The effect of full-contour Y-TZP ceramic surface roughness on the wear of bovine enamel and synthetic hydroxyapatite : an in-vitro study(2011) Sabrah, Alaá Hussein Aref, 1984-; Bottino, Marco C.; Lund, Melvin R., 1922-; Cochran, Michael A. (Michael Alan), 1944-; Hara, Anderson T.; Cook, Norman Blaine, 1954-THE EFFECT OF FULL-CONTOUR Y-TZP CERAMIC SURFACE ROUGHNESS ON THE WEAR OF BOVINE ENAMEL AND SYNTHETIC HYDROXYAPATITE: AN IN-VITRO STUDY by Alaa Hussein Aref Sabrah Indiana University School of Dentistry Indianapolis, Indiana Full-contour yttrium-stabilized tetragonal zirconia polycrystal (Y-TZP) restorations have been advocated recently in clinical situations where occlusal/palatal space is limited, or to withstand parafunctional activities. The objectives of this in-vitro study were to investigate the effects of different polishing techniques on the surface roughness of Y-TZP (Ardent Dental, Inc.) and to investigate the effects of different polishing techniques on the wear behavior of synthetic hydroxyapatite (HA) and bovine enamel. An in-vitro study was conducted by fabrication of 48 Y-TZP sliders (diameter = 2 mm × 1.5 mm in height) using CAD/CAM technique; then the samples were embedded in acrylic resin using brass holders. Samples were then randomly allocated into four groups according to the finishing/polishing procedure: G1-as-machined (n = 8), G2- glazed (n = 16), G3-diamond bur-finishing (Brasseler, USA) (n = 8) and G4- G3+OptraFine polishing kit (Ivoclar-Vivadent) (n = 16). Thirty-two sintered HA disks (diameter = 11 mm × 2.9 mm in height) and 16 bovine enamel samples with a minimum surface area of 64 mm2 were mounted in brass holders. Baseline surface roughness (Ra and Rq, in μm) were recorded using a non-contact profilometer (Proscan 2000) for all the samples. A two-body pin-on-disk wear test was performed for 25,000 cycles at 1.2 Hz in which the four zirconia groups were tested against HA, and only G2-glazed and G4- G3+OptraFine polishing kit (Ivoclar-Vivadent) were tested against bovine enamel. Vertical substance loss (μm) and volume loss (mm3) of HA were measured (Proscan). Zirconia height loss was measured using a digital micrometer. One-way ANOVA was used for statistical analysis. The results indicated that surface roughness measurements showed significant differences among the surface treatments with G1 (Ra = 0.84, Rq = 1.13 μm) and G3 (Ra = 0.89, Rq = 1.2 μm) being the roughest, and G2 (Ra = 0.42, Rq = 0.63 μm) the smoothest. The glazed group showed the highest vertical loss (35.39 μm) suggesting wear of the glaze layer, while the polished group showed the least vertical loss (6.61 μm). HA antagonist volume loss and vertical height loss for groups (G1, G2 and G3) were similar, while polished group (1.3 mm3, 14.7 μm) showed significant lower (p = 0.0001) values. Antagonist height loss and antagonist volume loss were significantly higher for bovine antagonist than for HA antagonist (197.6 μm/116.2 μm, and 28.5 mm3/17.7 mm3 for bovine against glazed/polished zirconia sliders, respectively) (p < 0.0001). From the results it can be concluded that glazed zirconia provided an initially smooth surface, but a significant increased antagonist wear compared with the polished surface was seen. Bovine enamel showed higher wear compared with HA, which suggested that more studies should be performed to validate the use of bovine enamel as a substitute for human enamel in wear studies.Item Effect of halloysite aluminosilicate clay nanotube incorporation into bonding agents on shear bond strength to human dentin(2013) Alkatheeri, Mohammed Saeed; Bottino, Marco C.; Chu, Tien-Min Gabriel; Platt, Jeffrey A., 1958-; Cook, Norman Blaine, 1954-; Cochran, Michael A. (Michael Alan), 1944-In adhesive dentistry, obtaining a good bond is a fundamental goal. It has been suggested that filler addition to the adhesives would increase the bonding strength of the adhesive layer. Halloysite aluminosilicate nanotubes (HNTs) are biocompatible, hydrophilic, durable, and have high mechanical strength. These advantages make them good candidates to be used as reinforcing agents for improving the properties of dental adhesives. The objective of this study was to evaluate the effect of incorporating HNTs into a commercial two-step etch-and-rinse adhesive system or one-step self-etch adhesive system on dentin shear bond strength. HNTs were incorporated into the two commercial adhesive systems in 0 wt%, 5 wt%, 10 wt%, and 20 wt%. The commercial control adhesives and the experimental adhesives were used to bond occlusal dentin of 120 extracted human molar teeth and then tested for shear bond strength by a universal testing machine with a semi-circular edge at a crosshead speed of 1.0 mm/min. Debonded specimens were examined under light microscopy to evaluate the fracture pattern. Resin-dentin interface were evaluated under scanning electron microscopy (SEM) after bonding dentin slabs using commercial control adhesives and experimental adhesive that showed numerically highest shear bond strength from each adhesive system. Two-way ANOVA was used to evaluate the effects of adhesive system and nanofiller content on shear bond strength. Pair-wise comparisons between groups were made using Fisher's (LSD) (p < 0.05). For the self-etch adhesive system, only incorporation of 5 wt% showed a significant increase in shear bond strength to dentin compared with the commercial control group. For the etch-and-rinse adhesive system, there was no significant difference in shear bond strength between HNTs filled adhesives groups and the commercial control group. Resin-dentin interface SEM evaluation showed nanotubes infiltrated into dentinal tubules. In conclusion, incorporating the self-etch adhesive system with 5 wt% HNTs increased the bond strength to dentin. Incorporation of up to 10 wt% filler concentration into both the self-etch and the etch-and-rinse adhesive systems did not adversely affect the bond strength to dentin or the handling properties. HNTs can penetrate along with resin tags into dentinal tubules, which could expand the use of their unique properties.Item Effect of surface conditioning methods on repair bond strength of microhybrid resin matrix composite(2010) Rajitrangson, Phitakphong, 1982-; Cochran, Michael A. (Michael Alan), 1944-; Cho, Sopanis D.; Gonzalez-Cabezas, Carlos, 1966-; Matis, Bruce A.; Platt, Jeffrey A., 1958-Repair is an alternative treatment option in many cases to replacement of resin matrix composite restoration. However, aged resin matrix composites have a limited number of carbon-carbon double bonds to adhere to a new layer of rein. Therefore, surface treatments of the aged resin matrix composite surface prior to repairing could improve the repair bond strength. The objectives of this study were to: 1) To evaluate various surface treatments on shear bond strength of repair between aged and new microhybrid resin matrix composite, and 2) To assess the influence of applying a silane coupling agent after surface treatments. Eighty disk-shaped resin matrix composite specimens were fabricated and thermocycled 5000 times prior to surface treatment. Specimens were randomly assigned to one of the three surface treatments (n = 20): 1) Airborne abrasion with 50 μm aluminum oxide, 2) Tribochemical silica coating (CoJet), or 3) Er,Cr:YSGG laser and control group (n = 20). Specimens were cleaned with 35-percent phosphoric acid, rinsed, and dried. Each group was assigned into two subgroups (n =10): a) no silanization, and b) with silanization. Adhesive agent was applied and new resin matrix composite was bonded to each conditioned surface. Bond strength was evaluated by shear test. Data were analyzed with a two-way ANOVA model. The interaction between conditioning and silanization was significant(p = 0.0163), indicating that comparisons of silanization must be evaluated for each conditioning method, and that comparisons of conditioning methods must be evaluated separately with and without silanization. Airborne particle abrasion showed significantly higher repair bond strength than Er,Cr:YSGG laser without silanization (p < 0.0001) and with silanization(p = 0.0002), and higher repair bond strength than the control without silanization (p < 0.00001) and with silanization (p < 0.00001). Airborne particle abrasion did not have significantly different in repair bond strength than Tribosilica coating without silanization (p = 0.70) or with silanization (p = 0.33). Tribosilica coating had significantly higher repair bond strength than Er,CR:YSGG laser without silanization (p < 0.0001) and with silanization (p < 0.0001), and significantly higher repair bond strength than control without silanization (p < 0.0001), but not with silanization (p =0.16). Er,CR:YSGG laser and control did not have significantly different repair bond strength without silanization (p = 1.00) or with silanization (p = 0.11). There was no effect of silanization on repair bond strength overall (p = 0.34) for any of the surface conditioning methods (p = 0.76 for airborne particle abrasion; p = 0.39 for tribosilica coating; p = 1.00 for Er,Cr:YSGG laser, or p = 0.39 for control). Airborne particle abrasion with 50-μm aluminum oxide particle and tribochemical silica coating followed by the application of bonding agent provided the highest shear bond strength values, suggesting that they might be adequate methods to improve the quality of the repairs of resin-matrix composites.Item Evaluation of water sorption and solubility behavior of nine different polymeric luting materials(2009) Alsheikh, Rasha N.; Platt, Jeffrey A.; Lund, Melvin R., 1922-; Cochran, Michael A. (Michael Alan), 1944-; Moore, B. Keith; Matis, Bruce A.The cementation procedure is the key to long-term success of fixed restorations. The prognosis of prosthetic restoration is largely impacted by the maintenance of the luting cement and the adhesive bond. When exposed to water or saliva, most restorative materials undergo hydrolytic degradation. The purpose of this study is to evaluate the water solubility and water sorption characteristics of newly introduced acidic polymeric luting agents over a 180-day water-storage period. Nine different luting agents were tested. Fifty-two disc specimens of each material were fabricated using a mold with an internal dimension of 15[plus-minus]0.1 mm in diameter and 1.0 [plus-minus]0.1 mm deep. A constant weight, W0 [subscript zero], was reached after desiccating the specimens. Then, 13 specimens were assigned randomly to one of the four testing periods in the water for seven, 30, 90 and 180 days. After each period, the specimens were removed from the water and weighed to get W1 [subscript one]. A second period of desiccating the samples provided a constant weight W2 [subscript two]. The water sorption and solubility were determined by the following equations: WSP [subscript SP](%) = (W1 [subscript one] W2 [subscript two] ) X 100/ W0 [subscript zero] ,WSL [subscript SL](%) = (W0 [subscript zero] W2 [subscript two) X 100/ W0 [subscript zero]. The resin-modified glass-ionomers showed the highest water sorption/solubility results. The resin luting agents had the lowest sorption/solubility results. The self-adhesives showed a wide range of solubility/sorption; in general, they showed lower results compared with the resin-modified glass-ionomers. All the materials reached some sort of equilibrium after 90-days. Based on the results of our study, we conclude that self-adhesive luting materials were not all alike. Rely X Unicem was the most comparable to the resin luting materials. The resin luting materials had the lowest solubility and sorption. Resin-modified glass-ionomers showed the highest sorption/solubility results.Item In-vitro wear and hardness of new conventional glass ionomer cement coated with nano-filled resin(2011) AlJamhan, Abdullah Saleh; Platt, Jeffrey Alan, 1958-; Matis, Bruce A.; Cochran, Michael A. (Michael Alan), 1944-; Cook, Norman Blaine, 1954-; Zandoná, Andréa G. Ferreira (Andréa Gonçalves Ferreira),1969-Background: Since the introduction of glass ionomer cements (GICs) in the 1970s, many attempts have been made to improve them and expand their application in restorative dentistry. Recently, GC America introduced a new glass ionomer restorative system called EQUIA. The manufacturer claims that this material has improved wear resistance by coating the surface of high-strength GIC with a nano-filled resin coating. Objective: The objective of this study was to measure the wear resistance and hardness of EQUIA and to compare it to other current restorative materials. Materials and Methods: Four different materials were used in this study: EQUIA, Fuji IX GP Extra, Fuji II LC and Z-100. Six specimens of each material were made and then tested in a toothbrush abrasion machine for 20,400 cycles, after which the amount of volume loss was calculated. Eight specimens of each material were made and tested in a three-body Alabama wear testing machine under a load of 75 N for 400,000 cycles. Four surface profiles were obtained from each specimen and volume loss was calculated using computer software. Five specimens of each material were made and Knoop microhardness was determined by using the mean of the three values from the top surface of the specimen. Results of each test were collected and compared with the other materials using one-way analysis of variance (ANOVA) at a significance level of 0.05. Results: Wear-resistance results showed that EQUIA has wear-resistance values comparable to composite resin and higher values than those for the high-strength GIC. The results also showed that Fuji II LC had the highest wear among all tested materials. Microhardness results showed that EQUIA has significantly lower microhardness than Fuji IX GP Extra and Z-100. Conclusion: Based on the results of the present study, it can be concluded that coating the surface of glass ionomer restorations with a nano-filled resin coat results in increasing the wear resistance and decreasing the microhardness of the material. Within the limitations of this study, EQUIA has comparable wear resistance to composite resin.Item The ion release behaviours and water sorption of novel resin-based calcium phosphate cement(2010) AlZain, Afnan Omar, 1981-; Chu, Tien-Min Gabriel; Lund, Melvin R., 1922-; Cochran, Michael A. (Michael Alan), 1944-; Martinez Mier, Esperanza de los A. (Esperanza de los Angeles), 1967-; Cook, Norman Blaine, 1954-Calcium phosphate-filled restorative materials were developed to provide calcium (Ca) and phosphate (PO4) ions, which have been proposed to enhance remineralization of demineralized tooth structure. Recently, tricalcium phosphate (TCP)-filled restorative materials were introduced as an alternative to amorphous calcium phosphate. The TCP filler has a more crystalline structure than ACP and is therefore potentially stronger. The aim of the present study was to examine TCP-filled restorative resins at different concentration levels at different time intervals to characterize the concentrations of Ca and PO4 ions released, and to measure the water sorption (WS) of these resins. An in vitro study was conducted by formulating resin composite using TCP as the filler mixed with EBPADMA, HmDMA, and HEMA as the resin matrix. One-hundred- sixty samples were prepared, 40 samples of each filler concentration (30 percent, 40 percent, 50 percent, and 60 percent) by weight. From each filler concentration, 5 samples of each of the 8 time points (time intervals of 4 h, 8 h, 12 h, 24 h, 3 d, 7 d, 14 d, and 21 d) were immersed in 100-ml deionized water. Calcium and PO4 ions were measured using atomic absorption spectroscopy and light spectroscopy, respectively. Water sorption (WS) was measured according to ISO 4049 specification and then the WS and the diffusion coefficient were calculated. The significance level was set at p = 0.001. The results indicated that Ca and PO4 ion release increased with increasing filler level at a rate faster than being linear. In addition, WS results were very high and failed to meet the ISO 4049 specification requirement. Diffusion coefficient results were also high. One-way ANOVA test for only 21-day data revealed that there is a statistically significant difference in filler level percent, and two-way ANOVA testing revealed that there is a statistically significant interaction between time and filler level percent on the Ca, PO4 released and WS. It can be concluded that the concentrations of Ca and PO4 released and WS were affected by composition of the monomers, filler level and type, dispersion, and the absence of coupling agent. Although this TCP-filled restorative material may release Ca and PO4, it cannot serve as a restorative material due to high WS values. Further study is needed to improve the material and evaluate its ability in promoting remineralization of the tooth structure in order for it to serve its purpose.Item Mechanical properties of a new zinc-reinforced glass ionomer restorative material(2012) Al-Angari, Sarah Sultan; Cook, Norman Blaine; Lund, Melvin R., 1922; Cochran, Michael A. (Michael Alan), 1944-; Chu, Tien-Min Gabriel; Platt, Jeffrey A., 1958-; Hara, Anderson T.Objective: Zinc-reinforced glass ionomer restorative material (ZRGIC) has been proposed as an improved restorative material. The study compared the mechanical properties of a ZRGIC restorative material (ChemFil Rock, (Dentsply)), with three commercially available glass ionomers (GICs); Fuji IX GP Extra (GC America), Ketac Molar (3M ESPE) and EQUIA Fil (GC America). A resin composite, Premise (Kerr), was included as a control group except for fracture toughness. Methods: Fracture toughness (KIC) testing was done according to ISO 13586, using single edge notched-beam specimens (n=10), loaded until failure in a three-point bending test device. Specimens (n=9) for the hardness, roughness and abrasive wear testing were made by mixing and inserting the restorative materials into individual stainless steel molds followed by flattening and polishing. Knoop microhardness (KHN) was performed (25 g, 30 s),on pre-determined areas of the polished surfaces. For toothbrushing wear resistance and roughness, specimens were brushed in an automated brushing machine (200 g) with a suspension of dentifrice and water (1:1, w/v) for 20,000 strokes. Specimen surfaces were scanned in an optical profilometer before and after brushing to obtain surface roughness (Ra) and mean height (surface) loss using image subtraction and dedicated software. Data were analyzed using Wilcoxon Rank Sum tests (α=0.05). Results: ChemFil Rock had the highest change in surface roughness (Ra)(0.79±0.14; p<0.001) and the lowest microhardness (KHN) values (52.39±2.67; p<0.05) among all GICs. Its wear resistance was comparable to other GICs (p>0.05). ChemFil Rock had lower fracture toughness (0.99±0.07, KIC) compared to Equia Fil (p<0.01) and higher compared to the other GICs (p<0.01). Conclusion: The new ZRGIC restorative material showed intermediate fracture toughness, high change in surface roughness, and low microhardness compared to three other commercial GICs. All materials were supplied by respective manufacturers.Item The Mechanical Properties of Full-Contour Zirconia(2014) Janabi, Anmar Uday; Chu, Tien-Min Gabriel; Matis, Bruce A.; Lund, Melvin R., 1922-; Cochran, Michael A. (Michael Alan), 1944-; Cook, Norman Blaine, 1954-The objectives: 1. To compare the flexural strength, flexural modulus, and fracture toughness of specimens fabricated from recently marketed translucent full-contour zirconia, traditional zirconia, and lithium disilicate glass ceramic. 2. To compare the load-to-failure of crowns fabricated from recently marketed translucent full-contour zirconia, traditional zirconia, and lithium disilicate glass ceramic at their recommended tooth-reduction thickness. Methodology: Four groups of translucent zirconia (BruxZir, KDZ Bruxer, CAP FZ, Suntech zirconia), one group of traditional zirconia (CAP QZ) and IPS e.maxCAD) were tested. Twelve bars of each material were made and tested for flexural strength, and fracture toughness. Fracture patterns were imaged under SEM. Forty-eight crowns (8 from each group) were fabricated with CAD/CAM technique following manufacturers’ recommendations for the amount of tooth reduction. All the crowns were cemented to prepared epoxy resin dies with RelyX Unicem and tested for static load to failure in a universal machine. Result: In bar-shape samples, CAP QZ (traditional zirconia) showed the highest flexural strength (788.12 MPa), fracture toughness (6.85 MPa.m1/2), and fracture resistance (2489.8 N). All translucent zirconia groups show lower mechanical properties than QZ. However, there were no differences between translucent and traditional zirconia in the fracture resistance of the crown-shape samples. There was no significant difference in fracture resistance between IPS e.max crowns at recommended thickness and other zirconia crowns at recommended thickness. Conclusion: With less reduction of tooth structure, a high inherent strength and chip resistance make full-zirconia crowns a good alternative to porcelain-fused-to-metal crowns and all other ceramic crowns.Item Microleakage in new resin-modified glass ionomer cements using new no-rinse conditioners : an in-vitro study(2012) Patel, Ashish G.; Cook, Norman Blaine, 1954-; Bottino, Marco C.; Cochran, Michael A. (Michael Alan), 1944-; Matis, Bruce A.; Hara, Anderson T.Since their introduction in 1970, glass ionomer cements have been used in a wide variety of clinical situations in dentistry. The main advantages of glass ionomer cements are chemical bonding, fluoride release and uptake, excellent seal against microleakage, and biocompatibility. The main objective of this study was to compare the microleakage of two new paste-paste glass ionomer systems to their traditional RMGIC counterparts when conditioning the dentin with newly developed no-rinse conditioners or polyacrylic acid. Materials and methods: Standardized cavity preparations were made, centered on the cementoenamel junction of the buccal surface, on 96 extracted human molars divided in 8 groups (n = 12). G1 Ketac Nano with Ketac Nano Primer, G2 Ketac Nano with Ketac Conditioner, G3 Photac Fil with Ketac Nano Primer, G4 Photac Fil with Ketac Cavity Conditioner, G5 Fuji Filling LC with GC Self Conditioner, G6 Fuji Filling LC with GC Cavity Conditioner, G7 Fuji II LC with GC Self Conditioner, G8 Fuji II LC with GC Cavity Conditioner. The cavities were treated with either a no-rinse or polyacrylic acid conditioner and restored with a paste-paste RMGIC or traditional RMGIC from the same manufacturer (n =12). The teeth were then sealed to within 2 mm of the restoration margins and thermocycled. The teeth were immersed in 2.0-percent methylene blue and stored at room temperature for 24 hours. Then, the teeth were be embedded in resin and sectioned longitudinally in a buccolingual direction making 1 section (1 mm thick) per tooth. The occlusal and gingival restoration margins of each specimen were examined with a stereomicroscope at X10 magnification to determine the degree of microleakage. Results: Mixed-model ANOVA was used to test the fixed effect of the eight groups and cervical vs. occlusal location within each tooth sample on microleakage, with sample as the random effect. Both main effects and the interaction are significant, p < 0001 for both group and location effects, and p = 0.0013 for the interaction of group and location. The cervical interface showed more microleakage in all groups except group 8 where microleakage was the same as at the occlusal margin. No significant difference was observed among groups for microleakage at the occlusal interface. There was significant difference among groups at the cervical interface with Fuji II LC using GC Cavity Conditioner performing best. For the occlusal interface Group 4 performed the best and Group 2 performed the worst, although the difference was not significant among the groups. For the cervical interface, Group 8 performed the best followed by Group 3, Group 4 and Group 6, although these four groups were not significantly different. For the cervical interface, group 2 performed the worst followed by group 1. Based on these results we can conclude that, overall, traditional RMGIC with polyacrylic acid conditioning performed better than the new paste-paste RMGIC systems utilizing the no-rinse conditioners.