Reference-Point Indentation Correlates with Bone Toughness Assessed Using Whole-Bone Traditional Mechanical Testing

dc.contributor.authorGallant, Maxime A.
dc.contributor.authorBrown, Drew M.
dc.contributor.authorOrgan, Jason M.
dc.contributor.authorAllen, Matthew R.
dc.contributor.authorBurr, David B.
dc.date.accessioned2014-07-08T19:30:15Z
dc.date.available2014-07-08T19:30:15Z
dc.date.issued2013-03
dc.description.abstractTraditional bone mechanical testing techniques require excised bone and destructive sample preparation. Recently, a cyclic-microindentation technique, reference-point indentation (RPI), was described that allows bone to be tested in a clinical setting, permitting the analysis of changes to bone material properties over time. Because this is a new technique, it has not been clear how the measurements generated by RPI are related to the material properties of bone measured by standard techniques. In this paper, we describe our experience with the RPI technique, and correlate the results obtained by RPI with those of traditional mechanical testing, namely 3-point bending and axial compression. Using different animal models, we report that apparent bone material toughness obtained from 3-point bending and axial compression is inversely correlated with the indentation distance increase (IDI) obtained from RPI with r2 values ranging from 0.50 to 0.57. We also show that conditions or treatments previously shown to cause differences in toughness, including diabetes and bisphosphonate treatment, had significantly different IDI values compared to controls. Collectively these results provide a starting point for understanding how RPI relates to traditional mechanical testing results.en_US
dc.identifier.citationGallant, M. A., Brown, D. M., Organ, J. M., Allen, M. R., & Burr, D. B. (2013). Reference-point indentation correlates with bone toughness assessed using whole-bone traditional mechanical testing. Bone, 53(1), 301-305.en_US
dc.identifier.urihttps://hdl.handle.net/1805/4624
dc.language.isoen_USen_US
dc.subjectboneen_US
dc.subjectmechanical testingen_US
dc.subjectmaterial propertiesen_US
dc.titleReference-Point Indentation Correlates with Bone Toughness Assessed Using Whole-Bone Traditional Mechanical Testingen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
gallant-2013-reference-point.pdf
Size:
1.56 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.88 KB
Format:
Item-specific license agreed upon to submission
Description: