Screening and Quantitation of Volatiles from Explosive Initiators and Plastic Bonded Explosives (PBX)

dc.contributor.advisorGoodpaster, John
dc.contributor.authorHecker, Alexis
dc.contributor.otherManicke, Nick
dc.contributor.otherBeymer, Christina
dc.date.accessioned2024-06-04T09:25:01Z
dc.date.available2024-06-04T09:25:01Z
dc.date.issued2024-05
dc.degree.date2024
dc.degree.disciplineForensic & Investigative Sciencesen
dc.degree.grantorPurdue Universityen
dc.degree.levelM.S.
dc.descriptionIUPUI
dc.description.abstractThe detection of explosives and explosive devices based upon the volatile compounds they emit is a long-standing tool for law enforcement and physical security. Towards that end, solid phase microextraction (SPME) combined with gas chromatography-mass spectrometry (GC-MS) has become a crucial analytical tool for the identification of volatiles emitted by explosives. Previous SPME studies have identified many volatile compounds emitted by common explosive formulations that serve as the main charge in explosive devices. However, limited research has been conducted on initiators like fuses, detonating cords, and boosters. In this study, a variety of SPME fiber coatings (i.e., polydimethylsiloxane (PDMS), polydimethylsiloxane/divinylbenzene (PDMS/DVB), divinylbenzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS), carboxen/polydimethylsiloxane (CAR/PDMS), and polyacrylate (PA)) were employed for the extraction and analysis of volatiles from Composition C-4 (cyclohexanone, 2-ethyl-1-hexanol, and 2,3-dimethyl-2,3-dinitrobutane (DMNB)) and Red Dot double-base smokeless powder (nitroglycerine, phenylamine). The results revealed that a PDMS/DVB fiber was optimal. Then, an assortment of explosive items (i.e., detonation cord, safety fuse, slip-on booster, and shape charge) were analyzed with a PDMS/DVB fiber. A variety of volatile compounds were identified, including plasticizers (tributyl acetyl citrate, N-butylbenzenesulfonamide), taggants (DMNB), and degradation products (2-ethyl-1-hexanol). Taggants, like DMNB, are one of the pivotal components added to explosives. These distinctive chemical markers, deliberately introduced during manufacturing to facilitate the identification of explosives, are commonly detected using SPME GC- MS, but their quantitation remains underexplored. To address this, we investigated total vaporization headspace (TV- HS) GC- MS for quantifying taggants in the headspace of Composition C4. Factors effecting the extraction of DMNB, such as shape and age of the sample, and surface depletion, were also examined. The results revealed that the shape of the sample did not affect the amount of DMNB in the headspace but the older the sample, the more DMNB was detected in the headspace. Surface depletion was also seen in samples that were exposed to air for more than one week. Then calibration curves with calibrants of DMNB in acetone were established for quantitation. The average concentration of DMNB in the headspace was determined to be 125 parts per million (ppm).
dc.identifier.urihttps://hdl.handle.net/1805/41164
dc.language.isoen_US
dc.rightsAttribution 4.0 Internationalen
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectgas chromatography mass spectrometry
dc.subjectexplosives detection methods
dc.subjectheadspace analysis
dc.subjecttotal vaporization technique
dc.subjectsoild phase microextraction
dc.subjectquantitation
dc.titleScreening and Quantitation of Volatiles from Explosive Initiators and Plastic Bonded Explosives (PBX)
dc.typeThesisen
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Hecker_Thesis (1).pdf
Size:
1.01 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: