Effects of kinetic cavity preparation vs. conventional handpiece preparation on the human dental pulp

dc.contributor.advisorSanders, Brian J.
dc.contributor.authorCollins, Julie M.en_US
dc.contributor.otherDean, Jeffrey A.
dc.contributor.otherZunt, Susan L., 1951-
dc.contributor.otherEl-Kafrawy, Abdel Hady, 1935-
dc.date.accessioned2013-11-15T12:25:56Z
dc.date.available2013-11-15T12:25:56Z
dc.date.issued1998
dc.degree.date1998en_US
dc.degree.disciplineSchool of Dentistryen_US
dc.degree.grantorIndiana Universityen_US
dc.degree.levelM.S.D.en_US
dc.descriptionIndiana University-Purdue University Indianapolis (IUPUI)en_US
dc.description.abstractThe purpose of this investigation was to compare the histopathologic effects of kinetic cavity preparation to the histopathologic effects of conventional high-speed handpiece preparation on the human dental pulp. The objective was to test the following hypothesis: kinetic cavity preparation results in significantly fewer pulpal effects than does conventional preparation using the high-speed handpiece. Class V cavity preparations were made in 26 teeth of seven patients who required extraction of these teeth for orthodontic purposes. Thirteen teeth were prepared using kinetic cavity preparation, using 27-um aluminum oxide particles at 160 pounds per square inch pressure. Thirteen were prepared using the high-speed handpiece and 330bur. Glass ionomer restorations were placed in all teeth. Extractions were done 10 to 15days after preparation. On teeth with closed apices, the apical one-third of the root was removed. All teeth were placed in 10 percent formalin solution. Teeth were sectioned and selected slides stained with hematoxylin and eosin for histologic evaluation. Microscopic findings indicated that the amount of remaining dentin was of significant thickness to be protective to the pulp. Pulpal responses ranged from no response in 22 specimens to a mild response in 4 specimens. Based on the results of this study, it was concluded that shallow preparation into the dentin does not cause pulpal damage at 10 to 15 days post-preparation, when using either kinetic cavity preparation or high-speed handpiece preparation. The hypothesis that kinetic cavity preparation causes significantly fewer pulpal effects than does conventional preparation with the high-speed handpiece was rejected.en_US
dc.identifier.urihttps://hdl.handle.net/1805/3672
dc.identifier.urihttp://dx.doi.org/10.7912/C2/1635
dc.language.isoen_USen_US
dc.subject.meshDental Cavity Preparation -- methodsen_US
dc.subject.meshDental Pulpen_US
dc.subject.meshDental High-Speed Equipmenten_US
dc.subject.meshKineticsen_US
dc.titleEffects of kinetic cavity preparation vs. conventional handpiece preparation on the human dental pulpen_US
dc.typeThesisen
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Collins.pdf
Size:
37.39 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.88 KB
Format:
Item-specific license agreed upon to submission
Description: