Flexural strength comparison of monolayer resin composite to bilayer resin/ liner composite

Date
2009
Authors
Language
American English
Embargo Lift Date
Department
Committee Chair
Degree
M.S.D.
Degree Year
2009
Department
School of Dentistry
Grantor
Indiana University
Journal Title
Journal ISSN
Volume Title
Found At
Abstract

Clinical evidence suggests that the use of liners in posterior composite restorations may increase the frequency of restoration fractures. Materials that have been used as liner materials for resin composite (RC) restoration include conventional glass ionomers, resin-modified glass ionomers (RMGI), and flowable composites. The aim of this study was to compare the flexural strength of a monolayer of resin composite with that of a bilayer of resin composite and liner. Four types of RC beams were tested: a monolayer control that is an un-lined RC (Tetric EvoCeram, Ivoclar Vivadent) and three “bilayer” specimens that consisted of this same RC lined with one of three liners. The three liners used included two RMGI cements (Vitrebond LC liner; 3M ESPE and, GC Fuji Lining LC; GC America) and a flowable resin composite (Tetric EvoFlow, Ivoclar Vivadent). Each group was tested after water storage for 24 h and 30 d. Altogether, eight, 12-specimen groups were fabricated and tested. Methods: A 25 x 2 x 2 mm mold was completely filled with the RC to form the control beams. To form the bilayer beams, this mold was filled with 0.5 mm of the liner and then with 1.5 mm of the RC. Specimens were stored in 37oC distilled for either 24 h or 30 d. Immediately prior to testing, the 30-day groups were also thermocycled 2500 times, between water baths at 7 oC and 48oC with a 30-s dwell time and a 10-s transit time. Flexural strength was determined using a three-point–bending device. A twoway analysis of variance (ANOVA) with interactions was used to investigate how liner group (or no liner) and storage time affected strength. Results: The interaction between liner type and storage time was significant (p = 0.0128). The un-lined RC (the monolayer beam) was significantly stronger after 24 h than after 30 d in water (p = 0.0098). Water storage between 24 h and 30 d did not change the flexural strength of any of the bilayer (lined) beams (p > 0.05). After storage for 24 h and also for storage for 30 d, both un-lined RC and RC lined with the flowable RC exhibited significantly higher flexural strength (p = 0.0001) than the bilayer beams lined with either RMGI liners.

Description
Indiana University-Purdue University Indianapolis (IUPUI)
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Rights
Source
Alternative Title
Type
Thesis
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Full Text Available at
This item is under embargo {{howLong}}