A Comparison of the Force-Moment Systems Generated by Orthodontic Stainless Steel T-loop and Triangular Springs

dc.contributor.advisorChen, Jie
dc.contributor.authorAlbright, David A.
dc.contributor.otherBaldwin, James J.
dc.contributor.otherHohlt, William F.
dc.contributor.otherKatona, Thomas R.
dc.contributor.otherShanks, James C.
dc.date.accessioned2023-07-06T13:12:47Z
dc.date.available2023-07-06T13:12:47Z
dc.date.issued1999
dc.degree.date1999en_US
dc.degree.disciplineSchool of Dentistryen
dc.degree.grantorIndiana Universityen_US
dc.degree.levelM.S.D.en_US
dc.descriptionIndiana University-Purdue University Indianapolis (IUPUI)en_US
dc.description.abstractThe force-moment systems of orthodontic T-loops have been widely described and investigated. A simpler triangular loop spring design has been employed in the graduate orthodontic clinic at Indiana University School of Dentistry. To date, no investigators have specifically examined and compared the force systems generated by these two loop configurations. The objective of this study was to compare the force systems generated by a T-loop and two different geometric shapes of triangular loops. A sample of 20 T-loops and 40 triangular loop springs were studied. The triangular loops were constructed in two different geometric configurations (n = 20 in each group) utilizing the same linear amount of wire as used in the T-loop fabrication. One set of triangular loops was the same height as the T-loop (isosceles shape); the other set was the same width as the T-loop (equilateral shape). Force and moment components along three mutually perpendicular axes (x, y, and z) were analyzed, with particular emphasis on the force system generated in the sagittal plane. The force-moment systems generated upon mesio-distal (x axis) activation were measured by a transducer connected to a computer for data collection and analysis. Statistical analysis utilized repeated measures of variance models (ANOVA). Multiple comparisons were made using Fisher's Protected Least Significant Differences at a 95-percent overall confidence level. On initial ligation, there were no significant differences between the loops in the M/F ratios in the sagittal plane (p = 0.75). For all other activation distances, the equilateral triangular loops produced greater M/F ratios than both the isosceles and T-loops (p = 0.0001), and the isosceles triangular loops generated greater M/F ratios than the T-loops (p < 0.0035).en_US
dc.identifier.urihttps://hdl.handle.net/1805/34149
dc.identifier.urihttp://dx.doi.org/10.7912/C2/3206
dc.language.isoen_USen_US
dc.subject.meshBiomechanical Phenomenaen_US
dc.subject.meshOrthodontic Appliances -- Statistics & Numerical Dataen_US
dc.titleA Comparison of the Force-Moment Systems Generated by Orthodontic Stainless Steel T-loop and Triangular Springsen_US
dc.typeThesisen
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Albright.pdf
Size:
51.38 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: