Stereoselective disposition of bupropion and its three major metabolites : 4-hydroxybupropion, erythro-dihydrobupropion, and threo-dihydrobupropion

dc.contributor.advisorJones, David R.
dc.contributor.authorMasters, Andrea Renee
dc.contributor.otherDesta, Zeruesenay
dc.contributor.otherZhang, Jian-Ting
dc.date.accessioned2016-09-15T21:25:33Z
dc.date.available2016-09-15T21:25:33Z
dc.date.issued2016-02-14
dc.degree.date2016en_US
dc.degree.disciplineDepartment of Pharmacology & Toxicologyen
dc.degree.grantorIndiana Universityen_US
dc.degree.levelM.S.en_US
dc.descriptionIndiana University-Purdue University Indianapolis (IUPUI)en_US
dc.descriptionA version of this thesis was published as: Masters AR, McCoy M, Jones DR, and Desta Z. Stereoselective method to quantify bupropion and its three major metabolites, hydroxybupropion, erythro-dihydrobupropion, and threo-dihydrobupropion using HPLC-MS/MS. J Chromatography B Analyt Technol Biomed Life Sci 1015-1016:201-208, 2016.en_US
dc.description.abstractBupropion is a dual dopamine-norepinephrine uptake inhibitor and a nicotine receptor antagonist. Clinically, bupropion is given as a racemate for the management of depression, smoking cessation aid, and for the management of weight. Bupropion has also been targeted as a phenotypic probe of CYP2B6 activity. Bupropion metabolites are formed via oxidation (4-hydroxybupropion) through CYP2B6, and reduction (erythro- and threo-dihydrobupropion) through carbonyl reductases. These metabolites exhibit pharmacological activity, but little is known regarding their stereoselective disposition due to the lack of a chiral assay. A novel reversed phase chiral-HPLC-MS/MS method involving a simple liquid-liquid extraction procedure and a small plasma sample volume (50µL) was developed that allowed simultaneous separation and quantification of enantiomers of bupropion, 4-hydroxybupropion, and those of threo- and erythro-dihydrobupropion in human plasma. This method was successfully implemented to determine the unique stereoselective disposition of bupropion and its metabolites in 15 human volunteers administered a single 100 mg oral dose of racemic bupropion. Significant differences (p<0.05) in the stereoselective metabolism were observed for all of the enantiomers. The highest plasma exposure (AUC0-∞) was (2R, 3R)-4-hydoxybupropion, almost 65 fold higher, than (2S, 3S)-4-hydoxybupropion, and over 32 fold greater than the parent R-bupropion. The second highest plasma exposure was threo-dihydrobupropion A, which was almost 5 fold higher than threo-dihydrobupropion B. (Nomenclature of the enantiomers for erythro- and threo-dihydrobupropion was based on the chromatography of the first eluting peak as “A” and the second eluting peak as “B”.) Threo-dihydrobupropion A and B showed the most significant difference between the racemic and enantiomer profiles. Although the AUC was greater for threo-dihydrobupropion B, threo-dihydrobupropion A had a significantly (p<0.05) higher Cmax. The half-life for threo-dihydrobupropion A and erythro-dihydrobupropion A were the longest for all analytes, which could indicate accumulation in multiple dosing. The importance of this study was, for the first time, to be able to characterize the stereoselective metabolism of bupropion and its three major metabolites. This new method and subsequent pharmacokinetic data should enhance further research into bupropion stereoselective metabolism, drug interactions, and effect.en_US
dc.description.versionA version of this thesis was published as: Masters AR, McCoy M, Jones DR, and Desta Z. Stereoselective method to quantify bupropion and its three major metabolites, hydroxybupropion, erythro-dihydrobupropion, and threo-dihydrobupropion using HPLC-MS/MS. J Chromatography B Analyt Technol Biomed Life Sci 1015-1016:201-208, 2016.en_US
dc.identifier.doi10.7912/C2X88M
dc.identifier.urihttps://hdl.handle.net/1805/10935
dc.identifier.urihttp://dx.doi.org/10.7912/C2/318
dc.language.isoen_USen_US
dc.subjectBupropionen_US
dc.subjectStereoselectiveen_US
dc.subjectHPLC-MS/MSen_US
dc.subject4-Hydroxybupropionen_US
dc.subjectThreo-dihydrobupropionen_US
dc.subjectErythro-dihydrobupropionen_US
dc.titleStereoselective disposition of bupropion and its three major metabolites : 4-hydroxybupropion, erythro-dihydrobupropion, and threo-dihydrobupropionen_US
dc.title.alternativeStereoselective method to quantify bupropion and its three major metabolites, hydroxybupropion, erythro-dihydrobupropion, and threo-dihydrobupropion using HPLC-MS/MSen_US
dc.typeThesisen
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Andrea Masters Thesis.pdf
Size:
717.19 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.88 KB
Format:
Item-specific license agreed upon to submission
Description: