Factors Associated with Traumatic Fluoroscopy-Guided Lumbar Punctures: A Retrospective Review

dc.contributor.authorYu, S. D.
dc.contributor.authorChen, M. Y.
dc.contributor.authorJohnson, A. J.
dc.contributor.departmentSurgery, School of Medicineen_US
dc.date.accessioned2021-04-28T17:08:35Z
dc.date.available2021-04-28T17:08:35Z
dc.date.issued2009-03-01
dc.description.abstractBACKGROUND AND PURPOSE: To minimize diagnostic confusion, a CSF specimen should be free from traumatically introduced red blood cells (RBCs). The purpose of this research is to determine if patient age, sex, gauge of the lumbar puncture (LP) needle, or the level of LP is associated with an increased risk for traumatic fluoroscopy-guided LP. MATERIALS AND METHODS: Data were collected retrospectively for consecutive male and female patients of all ages (n = 756) who underwent a fluoroscopy-guided LP for a 2-year period. We defined traumatic LP as a CSF sample with an RBC count more than 500 cells/mm3 without xanthochromia. RESULTS: Rate of traumatic LP was 13.3%. The rate of traumatic LP at the L4-L5 level (19%) was significantly higher than at the L2-L3 (9%) or L3-L4 level (10%). Patients older than 80 years had higher traumatic LP rates (25.9%) compared with patients between ages 11 and 80 years (12.4%). Sex and gauge of the spinal needle were not associated with increased rate of traumatic LP. Patients younger than 1 year had failed LP rate of 58.8% compared with 3.2% failure rate in older patients. CONCLUSIONS: Fluoroscopy-guided LP at the L4-L5 level is associated with nearly twice the risk for traumatic puncture compared with the L2-L3 or L3-L4 level. Rates of traumatic result are twice as high in adults older than 80 years compared with younger patients. Failure rates for fluoroscopy-guided LP are low except in children younger than 1 year, in whom failure occurs in most cases.en_US
dc.identifier.citationYu, S. D., Chen, M. Y., & Johnson, A. J. (2009). Factors Associated with Traumatic Fluoroscopy-Guided Lumbar Punctures: A Retrospective Review. American Journal of Neuroradiology, 30(3), 512–515. https://doi.org/10.3174/ajnr.A1420en_US
dc.identifier.issn0195-6108, 1936-959Xen_US
dc.identifier.urihttps://hdl.handle.net/1805/25780
dc.language.isoen_USen_US
dc.publisherAmerican Journal of Neuroradiologyen_US
dc.relation.isversionof10.3174/ajnr.A1420en_US
dc.relation.journalAmerican Journal of Neuroradiologyen_US
dc.sourcePMCen_US
dc.subjectLumbar Puncturesen_US
dc.subjectCerebrospinal Fluiden_US
dc.subjecttraumatic fluoroscopy-guided LPen_US
dc.titleFactors Associated with Traumatic Fluoroscopy-Guided Lumbar Punctures: A Retrospective Reviewen_US
dc.typeArticleen_US
ul.alternative.fulltexthttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC7051446/en_US
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Factors Associated with Traumatic Fluoroscopy-Guided Lumbar Punctures_ A Retrospective Review.pdf
Size:
423.32 KB
Format:
Adobe Portable Document Format
Description:
Main article
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: