The Comparison of the Tensile, Shear-Peel, and Torque Orthodontic Bond Strength Test Methods Performed on a Resin and Two Glass Ionomer Cements

dc.contributor.advisorKatona, Thomas R.
dc.contributor.authorMadding, Sigrid Elaine
dc.contributor.otherArbuckle, Gordon R.
dc.contributor.otherMoore, B. Keith
dc.contributor.otherShanks, James C.
dc.contributor.otherWillis, George P.
dc.date.accessioned2023-11-10T14:37:02Z
dc.date.available2023-11-10T14:37:02Z
dc.date.issued1996
dc.degree.date1996
dc.degree.disciplineSchool of Dentistryen
dc.degree.grantorIndiana Universityen
dc.degree.levelM.S.D.
dc.descriptionIndiana University-Purdue University Indianapolis (IUPUI)en
dc.description.abstractThe purpose of this study was to compare the tensile, shear-peel, and torque bond strength testing methods using a commercially available resin (R), light-cured (LC), and chemically cured (CC) glass ionomer. Sixty-three bovine incisors were randomly divided into three groups. Stainless steel incisor brackets were bonded to the prepared facial surfaces, and the specimens were stored in deionized water at 37° C for 38 hours. The specimens were then tested to failure using three loading modes. The bracket and enamel surfaces of each specimen were visually examined to determine the site of bond failure. R had the highest mean tensile, shear-peel, and torque bond strength. LC had a higher mean shear-peel and torque bond strength than CC. Tension testing left more adhesive than shear-peel and torque for CC, and more than shear-peel for R. The amount of LC left on enamel is positively correlated with bond strength for tension, shear-peel and torque. R remaining on enamel was positively correlated with bond strength only in tension. This study illustrates that loading mode does not appear to affect the relative bond strengths.
dc.identifier.urihttps://hdl.handle.net/1805/37030
dc.language.isoen_US
dc.subjectDental Bonding
dc.subjectComposite Resins
dc.subjectGlass Ionomer Cements
dc.subjectOrthodontic Brackets
dc.subject.meshDental Bonding
dc.subject.meshGlass Ionomer Cements
dc.subject.meshOrthodontic Brackets
dc.subject.meshCattle
dc.subject.meshTensile Strength
dc.subject.meshTorque
dc.subject.meshResin Cements
dc.titleThe Comparison of the Tensile, Shear-Peel, and Torque Orthodontic Bond Strength Test Methods Performed on a Resin and Two Glass Ionomer Cements
dc.typeThesisen
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Madding.pdf
Size:
55.31 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: