Ion Mobility Spectrometry : Optimization of Parameters in Collision Cross Sections and Trace Detection of Explosives

dc.contributor.advisorLarriba Andaluz, Carlos
dc.contributor.authorWu, Tianyang
dc.contributor.otherZhu, Likun
dc.contributor.otherTovar, Andres
dc.date.accessioned2018-12-10T13:39:45Z
dc.date.available2018-12-10T13:39:45Z
dc.date.issued2018-12
dc.degree.date2018en_US
dc.degree.disciplineMechanical Engineeringen
dc.degree.grantorPurdue Universityen_US
dc.degree.levelM.S.M.E.en_US
dc.descriptionIndiana University-Purdue University Indianapolis (IUPUI)en_US
dc.description.abstractIon mobility spectrometry is a powerful technique for the study related to molecule. The work of tow major applications are introduced in this paper. The first application is the optimization of parameters in CCS. The accurate calculation of the collision cross section for multiple molecules is a long-time interested topic in the research for substances detection in micro scale. No reliable analytical approach to calculate the collision cross section has been established to date. Different approaches rely on different mechanism will provide different results in significant extent. This work introduce a method for the determination of parameters in the Lennard Jones potential. Experimental data combined with numerical computation was the fundamental strategy during the optimization of the parameters. In the experiment, electrospray is used as the ion source of IMS while a nebulizer was utilized to electrify the aromatic compounds. New parameters show no less accuracy and equal efficiency while can explain the physical meaning of the collision more clearly. The second application is the trace detection of explosives with very low concentration. The detection of explosives is an important topic in security, while the detection will be difficult due to the low vapor pressure of explosives. In this work, two types of devices are designed for the trace detection of explosives at an extremely low concentration. TNT is selected as the explosives in the experiment. The experiment succeed to reach a sensitivity of 1 part per quintillion, and even find out a linear relationship between the logarithm of TNT concentration and TNT vapor pressure.en_US
dc.identifier.urihttps://hdl.handle.net/1805/17956
dc.identifier.urihttp://dx.doi.org/10.7912/C2/2641
dc.language.isoenen_US
dc.rightsAttribution 3.0 United States
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/us/
dc.subjectIon Mobility Spectrometryen_US
dc.subjectMass Spectrometryen_US
dc.subjectCollision Cross Sectionen_US
dc.subjectExplosive Detectionen_US
dc.titleIon Mobility Spectrometry : Optimization of Parameters in Collision Cross Sections and Trace Detection of Explosivesen_US
dc.typeThesisen
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
TianyangWuThesis.pdf
Size:
7.69 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: