Quantitative Analysis of Humectants in Tobacco Products Using Gas Chromatography (GC) with Simultaneous Mass Spectrometry (MSD) and Flame Ionization Detection (FID)

Date
2013-06
Language
American English
Embargo Lift Date
Department
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Abstract

This paper describes the modification of an existing gas chromatographic (GC) method to incorporate simultaneous mass spectrometric (MSD) and flame ionization detection (FID) into the analysis of tobacco humectants. Glycerol, propylene glycol, and triethylene glycol were analyzed in tobacco labeled as roll-your-own (RYO), cigar, cigarette, moist snuff, and hookah tobacco. Tobacco was extracted in methanol containing 1,3-butanediol (internal standard), filtered, and separated on a 15 m megabore DB-Wax column. Post-column flow was distributed using a microfluidic splitter between the MSD and FID for simultaneous detection. The limits of detection for the FID detector were 0.5 μg/mL (propylene glycol and triethylene glycol) and 0.25 μg/mL (glycerol) with a linear range of 2–2000 μg/mL (propylene glycol and triethylene glycol) and 1–4000 μg/mL (glycerol). The limits of detection for the MSD detector were 2 μg/mL (propylene glycol and triethylene glycol) and 4 μg/mL (glycerol) with a linear range of 20–2000 μg/mL (propylene glycol and triethylene glycol) and 40–4000 μg/mL (glycerol). Significant improvement in the sensitivity of the MSD can be achieved by employing selective ion monitoring (SIM) detection mode. Although a high degree of correlation was observed between the results from FID and MSD analyses, marginal chromatographic resolution between glycerol and triethylene glycol limits the applicability of FID to samples containing low levels of both of these humectants. Utilizing MSD greatly improves the reliability of quantitative results because compensation for inadequate chromatographic resolution can be accomplished with mass selectivity in detection.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Rainey, C. L., Shifflett, J. R., Goodpaster, J. V., Bezabeh, D. Z., & St, L. D. (2013). Quantitative Analysis of Humectants in Tobacco Products Using Gas Chromatography (GC) with Simultaneous Mass Spectrometry (MSD) and Flame Ionization Detection (FID). Beiträge zur Tabakforschung International/Contributions to Tobacco Research, 25(6), 576-585.
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Rights
Source
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Full Text Available at
This item is under embargo {{howLong}}