Motion correction of PET/CT images

dc.contributor.advisorSalama, Paul
dc.contributor.authorChong Chie, Juan Antonio Kim Hoo
dc.contributor.otherTerrito, Paul
dc.date.accessioned2017-04-27T21:54:00Z
dc.date.available2018-04-28T09:30:17Z
dc.date.issued2017
dc.degree.date2017en_US
dc.degree.disciplineElectrical & Computer Engineeringen
dc.degree.grantorPurdue Universityen_US
dc.degree.levelM.S.E.C.E.en_US
dc.descriptionIndiana University-Purdue University Indianapolis (IUPUI)en_US
dc.description.abstractThe advances in health care technology help physicians make more accurate diagnoses about the health conditions of their patients. Positron Emission Tomography/Computed Tomography (PET/CT) is one of the many tools currently used to diagnose health and disease in patients. PET/CT explorations are typically used to detect: cancer, heart diseases, disorders in the central nervous system. Since PET/CT studies can take up to 60 minutes or more, it is impossible for patients to remain motionless throughout the scanning process. This movements create motion-related artifacts which alter the quantitative and qualitative results produced by the scanning process. The patient's motion results in image blurring, reduction in the image signal to noise ratio, and reduced image contrast, which could lead to misdiagnoses. In the literature, software and hardware-based techniques have been studied to implement motion correction over medical files. Techniques based on the use of an external motion tracking system are preferred by researchers because they present a better accuracy. This thesis proposes a motion correction system that uses 3D affine registrations using particle swarm optimization and an off-the-shelf Microsoft Kinect camera to eliminate or reduce errors caused by the patient's motion during a medical imaging study.en_US
dc.identifier.doi10.7912/C2BS9W
dc.identifier.urihttps://hdl.handle.net/1805/12353
dc.identifier.urihttp://dx.doi.org/10.7912/C2/2481
dc.language.isoen_USen_US
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 United States
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/
dc.subjectPET/CTen_US
dc.subjectMotion Correctionen_US
dc.subjectParticle Swarm Optimizationen_US
dc.titleMotion correction of PET/CT imagesen_US
dc.typeThesisen
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Chong Chie Thesis.pdf
Size:
6.76 MB
Format:
Adobe Portable Document Format
Description:
Thesis file
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.88 KB
Format:
Item-specific license agreed upon to submission
Description: