- Browse by Subject
Browsing by Subject "plastic stents"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Effect of Covered Metallic Stents Compared With Plastic Stents on Benign Biliary Stricture Resolution A Randomized Clinical Trial(JAMA, 2016-03) Coté, Gregory A.; Slivka, Adam; Tarnasky, Paul; Mullady, Daniel K.; Elmunzer, B. Joseph; Elta, Grace; Fogel, Evan; Lehman, Glen; McHenry, Lee; Romagnuolo, Joseph; Menon, Shyam; Siddiqui, Uzma D.; Watkins, James; Lynch, Sheryl; Denski, Cheryl; Xu, Huiping; Sherman, Stuart; Department of Biostatistics, Richard M. Fairbanks School of Public HealthImportance Endoscopic placement of multiple plastic stents in parallel is the first-line treatment for most benign biliary strictures; it is possible that fully covered, self-expandable metallic stents (cSEMS) may require fewer endoscopic retrograde cholangiopancreatography procedures (ERCPs) to achieve resolution. Objective To assess whether use of cSEMS is noninferior to plastic stents with respect to stricture resolution. Design, Setting, and Participants Multicenter (8 endoscopic referral centers), open-label, parallel, randomized clinical trial involving patients with treatment-naive, benign biliary strictures (N = 112) due to orthotopic liver transplant (n = 73), chronic pancreatitis (n = 35), or postoperative injury (n = 4), who were enrolled between April 2011 and September 2014 (with follow-up ending October 2015). Patients with a bile duct diameter less than 6 mm and those with an intact gallbladder in whom the cystic duct would be overlapped by a cSEMS were excluded. Interventions Patients (N = 112) were randomized to receive multiple plastic stents or a single cSEMS, stratified by stricture etiology and with endoscopic reassessment for resolution every 3 months (plastic stents) or every 6 months (cSEMS). Patients were followed up for 12 months after stricture resolution to assess for recurrence. Main Outcomes and Measures Primary outcome was stricture resolution after no more than 12 months of endoscopic therapy. The sample size was estimated based on the noninferiority of cSEMS to plastic stents, with a noninferiority margin of −15%. Results There were 55 patients in the plastic stent group (mean [SD] age, 57 [11] years; 17 women [31%]) and 57 patients in the cSEMS group (mean [SD] age, 55 [10] years; 19 women [33%]). Compared with plastic stents (41/48, 85.4%), the cSEMS resolution rate was 50 of 54 patients (92.6%), with a rate difference of 7.2% (1-sided 95% CI, −3.0% to ∞; P < .001). Given the prespecified noninferiority margin of −15%, the null hypothesis that cSEMS is less effective than plastic stents was rejected. The mean number of ERCPs to achieve resolution was lower for cSEMS (2.14) vs plastic (3.24; mean difference, 1.10; 95% CI, 0.74 to 1.46; P < .001). Conclusions and Relevance Among patients with benign biliary strictures and a bile duct diameter 6 mm or more in whom the covered metallic stent would not overlap the cystic duct, cSEMS were not inferior to multiple plastic stents after 12 months in achieving stricture resolution. Metallic stents should be considered an appropriate option in patients such as these.Item Safety and efficacy of lumen-apposing metal stents versus plastic stents to treat walled-off pancreatic necrosis: systematic review and meta-analysis(Thieme, 2020-11) Chandrasekhara, Vinay; Barthet, Marc; Devière, Jacques; Bazerbachi, Fateh; Lakhtakia, Sundeep; Easler, Jeffrey J.; Peetermans, Joyce A.; McMullen, Edmund; Gjata, Ornela; Gourlay, Margaret L.; Abu Dayyeh, Barham K.; Medicine, School of MedicineBackground and study aims Lumen-apposing metal stents (LAMS) are increasingly used for drainage of walled-off pancreatic necrosis (WON). Recent studies suggested greater adverse event (AE) rates with LAMS for WON. We conducted a systematic review and meta-analysis to compare the safety and efficacy of LAMS with double-pigtail plastic stents (DPPS) for endoscopic drainage of WON. The primary aim was to evaluate stent-related AEs. Methods In October 2019, we searched the Ovid (Embase, MEDLINE, Cochrane) and Scopus databases for studies assessing a specific LAMS or DPPS for WON drainage conducted under EUS guidance. Safety outcomes were AE rates of bleeding, stent migration, perforation, and stent occlusion. Efficacy outcomes were WON resolution and number of procedures needed to achieve resolution. A subanalysis including non-EUS-guided cases was performed. Results Thirty studies including one randomized controlled trial (total 1,524 patients) were analyzed. LAMS were associated with similar bleeding (2.5 % vs. 4.6 %, P = 0.39) and perforation risk (0.5 % vs. 1.1 %, P = 0.35) compared to DPPS. WON resolution (87.4 % vs. 87.5 %, P = 0.99), number of procedures to achieve resolution (2.09 vs. 1.88, P = 0.72), stent migration (5.9 % vs. 6.8 %, P = 0.79), and stent occlusion (3.8 % vs. 5.2 %, P = 0.78) were similar for both groups. Inclusion of non-EUS-guided cases led to significantly higher DPPS bleeding and perforation rates. Conclusions LAMS and DPPS were associated with similar rates of AEs and WON resolution when limiting analysis to EUS-guided cases. Higher bleeding rates were seen in historical studies of DPPS without EUS guidance. Additional high-quality studies of WON treatment using consistent outcome definitions are needed.