- Browse by Subject
Browsing by Subject "QLF-D"
Now showing 1 - 1 of 1
Results Per Page
Sort Options
Item Performance of several diagnostic systems on detection of occlusal primary caries in permanent teeth(2014) Jallad, Mahmoud; Zero, Domenick T.; Chu, Tien-Min Gabriel; Cochran, Michael A. (Michael Alan), 1944-; Cook, Norman Blaine, 1954-; Zandoná, Andréa F.Detection of caries at an early stage is unequivocally essential for early preventive intervention. Longitudinal assessment of caries lesions, especially under the opaque preventive sealant, would be of utmost importance to the dental community. OBJECTIVES: The aim of this two-part in-vitro study is to evaluate the performance of multiple detection methods: The International Caries Detection and Assessment System (ICDAS); two quantitative light-induced fluorescence systems QLF; Inspektor™ Pro and QLF-D Biluminator™2 (Inspektor Research Systems B.V.; Amsterdam, The Netherlands); and photothermal radiometry and modulated luminescence (PTR/LUM) of The Canary System® (Quantum Dental Technologies; Toronto, Canada). All these are to be evaluated on their detection of caries on posterior human permanent teeth for 1) of primary occlusal lesions, and 2) under the sealant of primary occlusal lesions. METHODS: One hundred and twenty (N = 120) human posterior permanent teeth, selected in compliance with IU-IRB “Institutional Review Board” standards, with non-cavitated occlusal lesions ICDAS (scores 0 to 4) were divided into two equal groups. The second group (N = 60) received an opaque resin dental sealant (Delton® Light-Curing Pit and Fissure Sealant Opaque, Dentsply, York, PA). All lesions were assessed with each detection method twice in a random order except for ICDAS, which was not used following the placement of the sealant. Histological validation was used to compare methods in regard to sensitivity, specificity, % correct, and the area under receiver- operating characteristic curve (AUC). Intra-examiner repeatability and inter-examiner agreement were measured using intraclass correlation coefficient (ICC). RESULTS: 1) Of primary occlusal lesions, sensitivity, specificity, and AUC values were respectively: 0.82, 0.86 and 0.87 (ICDAS); 0.89, 0.60 and 0.90 (Inspektor Pro); 0.96, 0.57 and 0.94 (QLF-D Biluminator 2); and 0.85, 0.43 and 0.79 (The Canary System). Intra-examiner repeatability and inter-examiner agreement were respectively: 0.81 to 0.87: 0.72 (ICDAS); 0.49 to 0.97: 0.73 (Inspektor Pro); 0.96 to 0.99: 0.96 (QLF-D Biluminator 2); and 0.33 to 0.63: 0.48 (The Canary System). 2) Of primary occlusal lesions under the opaque dental sealants, sensitivity, specificity, and AUC values were respectively: 0.99, 0.03 and 0.67 (Inspektor Pro); 1.00, 0.00 and 0.70 (QLF-D Biluminator 2); and 0.54, 0.50 and 0.58 (The Canary System). Intra-examiner repeatability and inter-examiner agreement were respectively: 0.24 to 0.37: 0.29 (Inspektor Pro); 0.80 to 0.84: 0.74 (QLF-D Biluminator 2); and 0.22 to 0.47: 0.01 (The Canary System). CONCLUSION: Limited to these in-vitro conditions, 1) ICDAS remains the method of choice for detection of early caries lesion due to its adequately high accuracy and repeatability. QLF systems demonstrate potential in longitudinal monitoring due to an almost perfect repeatability of QLF-D Biluminator 2. The Canary System performance and repeatability were not acceptable as a valid method of early caries detection. 2) None of the methods demonstrated acceptable ability in detecting of occlusal caries under the opaque sealant. However, QLF-D Biluminator 2, with limitation to these in-vitro conditions and Delton opaque sealant, demonstrated a fair accuracy AUC (0.70) in detecting of caries under sealants at an experimental threshold of 12.5% ΔF.