- Browse by Subject
Browsing by Subject "Endoscopic retrograde cholangiopancreatography"
Now showing 1 - 7 of 7
Results Per Page
Sort Options
Item A comparative study between single-operator pancreatoscopy with intraductal lithotripsy and extracorporeal shock wave lithotripsy for the management of large main pancreatic duct stones(Springer, 2022) Bick, Benjamin L.; Patel, Feenalie; Easler, Jeffrey J.; Tong, Yan; Watkins, James L.; McHenry, Lee; Lehman, Glen; Fogel, Evan L.; Gromski, Mark A.; Sherman, Stuart; Medicine, School of MedicineBackground and aims: Endoscopic management of large main pancreatic ductal (MPD) stones often require treatment with lithotripsy. Extracorporeal shock wave lithotripsy (ESWL) has been the mainstay therapy, and single-operator pancreatoscopy with intraductal (intracorporeal) lithotripsy (SOPIL) is an emerging technique. However, no comparative studies between these techniques exist. We therefore aimed to compare ESWL to SOPIL for the treatment of large MPD stones. Methods: This is a retrospective cohort study comparing patients who were treated with ESWL or SOPIL from September 2013 to September 2019 at a single tertiary center. Logistic regression was performed to identify factors associated with technical success and efficient stone clearance (≤ 2 procedures to clear stones). Results: There were 240 patients who were treated with ESWL and 18 treated with SOPIL. The overall technical success rate of stone clearance was 224/258 (86.8%), which was similar between the ESWL and SOPIL groups (86.7% vs 88.9%, p = 1.000). A SOPIL approach required fewer total procedures (1.6 ± 0.6 vs 3.1 ± 1.5, p < 0.001) and less aggregate procedure time (101.6 ± 68.2 vs 191.8 ± 111.6 min, p = 0.001). Adverse event rates were similar between the groups (6.3% vs 5.6%, p = 1.000). The use of SOPIL was independently associated with greater efficiency compared to ESWL (OR 5.241 [1.348-20.369], p = 0.017). Stone size > 10 mm was associated with less efficient stone clearance (OR 0.484 [0.256-0.912], p = 0.025). Conclusion: Both ESWL and SOPIL are safe and effective endoscopic adjunct modalities for treating large pancreatic duct stones. SOPIL is an emerging alternative to ESWL that is potentially more efficient for lithotripsy and MPD stone clearance.Item Development and initial validation of an instrument for video-based assessment of technical skill in ERCP(Elsevier, 2021) Elmunzer, B. Joseph; Walsh, Catharine M.; Guiton, Gretchen; Serrano, Jose; Chak, Amitabh; Edmundowicz, Steven; Kwon, Richard S.; Mullady, Daniel; Papachristou, Georgios I.; Elta, Grace; Baron, Todd H.; Yachimski, Patrick; Fogel, Evan L.; Draganov, Peter V.; Taylor, Jason R.; Scheiman, James; Singh, Vikesh K.; Varadarajulu, Shyam; Willingham, Field F.; Cote, Gregory A.; Cotton, Peter B.; Simon, Violette; Spitzer, Rebecca; Keswani, Rajesh; Wani, Sachin; SVI study group; U.S. Cooperative for Outcomes Research in Endoscopy; Medicine, School of MedicineBackground and aims: The accurate measurement of technical skill in ERCP is essential for endoscopic training, quality assurance, and coaching of this procedure. Hypothesizing that technical skill can be measured by analysis of ERCP videos, we aimed to develop and validate a video-based ERCP skill assessment tool. Methods: Based on review of procedural videos, the task of ERCP was deconstructed into its basic components by an expert panel that developed an initial version of the Bethesda ERCP Skill Assessment Tool (BESAT). Subsequently, 2 modified Delphi panels and 3 validation exercises were conducted with the goal of iteratively refining the tool. Fully crossed generalizability studies investigated the contributions of assessors, ERCP performance, and technical elements to reliability. Results: Twenty-nine technical elements were initially generated from task deconstruction. Ultimately, after iterative refinement, the tool comprised 6 technical elements and 11 subelements. The developmental process achieved consistent improvements in the performance characteristics of the tool with every iteration. For the most recent version of the tool, BESAT-v4, the generalizability coefficient (a reliability index) was .67. Most variance in BESAT scores (43.55%) was attributed to differences in endoscopists' skill, indicating that the tool can reliably differentiate between endoscopists based on video analysis. Conclusions: Video-based assessment of ERCP skill appears to be feasible with a novel instrument that demonstrates favorable validity evidence. Future steps include determining whether the tool can discriminate between endoscopists of varying experience levels and predict important outcomes in clinical practice.Item Identification and management of pancreas divisum(Taylor & Francis, 2019-11) Gutta, Aditya; Fogel, Evan; Sherman, Stuart; Medicine, School of MedicineIntroduction: Pancreas divisum is the most common congenital malformation of the pancreas with the majority asymptomatic. The etiological role, pathogenesis, clinical significance and management of pancreas divisum in pancreatic disease has not been clearly defined and our understanding is yet to be fully elucidated.Areas covered: This review describes the role of pancreas divisum in the development of pancreatic disease and the ambiguity related to it. In our attempt to offer clarity, a comprehensive search on PubMed, Ovid, Embase and Cochrane Library from inception to May 2019 was undertaken using key words "pancreas divisum", "idiopathic recurrent acute pancreatitis" and "chronic pancreatitis".Expert opinion: Current research fails to define a clear association between pancreas divisum and pancreatic disease. Though debatable, several studies do suggest a pathological role of pancreas divisum in pancreatic disease and a benefit of minor papilla therapy in the setting of acute recurrent pancreatitis. Surgical and endoscopic therapeutic modalities have not been directly compared. With the current data available, it would be imprudent to advise a definitive line of management for pancreatic disease associated with pancreas divisum and should involve a comprehensive discussion with the individual patient to define expectations before embarking on any medical and/or interventional therapy.Item Is Endoscopic Ultrasound-Guided Hepaticogastrostomy Safe and Effective after Failed Endoscopic Retrograde Cholangiopancreatography?—A Systematic Review and Meta-Analysis(MDPI, 2024-07-01) Alsakarneh, Saqr; Madi, Mahmoud Y.; Dahiya, Dushyant Singh; Jaber, Fouad; Kilani, Yassine; Ahmed, Mohamed; Beran, Azizullah; Abdallah, Mohamed; Al Ta’ani, Omar; Mittal, Anika; Numan, Laith; Goyal, Hemant; Bilal, Mohammad; Kiwan, Wissam; Medicine, School of MedicineBackground/Objectives: Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) has emerged as an alternative option for biliary drainage in cases of failed endoscopic retrograde cholangiopancreatography (ERCP). Limited data exist on the safety and efficacy of EUS-HGS. In this comprehensive meta-analysis, we aim to study the safety and efficacy of EUS-HGS in cases of failed conventional ERCP. Methods: Embase, PubMed, and Web of Science databases were searched to include all studies that evaluated the efficacy and safety of EUS-HGS. Using the random effect model, the pooled weight-adjusted event rate estimate for clinical outcomes in each group were calculated with 95% confidence intervals (CIs). The primary outcomes were technical and clinical success rates. Secondary outcomes included overall adverse events (AEs), rates of recurrent biliary obstruction (RBO), and rates or re-intervention. Results: Our analysis included 70 studies, with a total of 3527 patients. The pooled technical and clinical success rates for EUS-HGS were 98.1% ([95% CI, 97.5–98.7]; I2 = 40%) and 98.1% ([95% CI, 97.5–98.7]; I2 = 40%), respectively. The pooled incidence rate of AEs with EUS-HGS was 14.9% (95% CI, 12.7–17.1), with bile leakage being the most common (2.4% [95% CI, 1.7–3.2]). The pooled incidence of RBO was 15.8% [95% CI, 12.2–19.4], with a high success rate for re-intervention (97.5% [95% CI, 94.7–100]). Conclusions: Our analysis showed high technical and clinical success rates of EUS-HGS, making it a feasible and effective alternative to ERCP. The ongoing development of dedicated devices and techniques is expected to make EUS-HGS more accessible and safer for patients in need of biliary drainage.Item Prevention of post-ERCP pancreatitis: the search continues(Elsevier, 2021-05) Easler, Jeffrey J.; Fogel, Evan L.; Medicine, School of MedicineItem Provider Specific Quality Measurement for Endoscopic Retrograde Cholangiopancreatography Utilizing Natural Language Processing(Elsevier, 2018-01) Imler, Timothy D.; Sherman, Stuart; Imperiale, Thomas F.; Xu, Huiping; Ouyang, Fangqian; Beesley, Christopher; Hilton, Charity; Coté, Gregory A.; Medicine, School of MedicineBACKGROUND AND AIMS: Natural language processing (NLP) is an information retrieval technique that has been shown to accurately identify quality measures for colonoscopy. There are no systematic methods by which to track adherence to quality measures for ERCP, the highest risk endoscopic procedure widely used in practice. Our aim was to demonstrate the feasibility of using NLP to measure adherence to ERCP quality indicators across individual providers. METHODS: ERCPs performed by 6 providers at a single institution from 2006 to 2014 were identified. Quality measures were defined using society guidelines and from expert opinion, and then extracted using a combination of NLP and data mining (eg, ICD9-CM codes). Validation for each quality measure was performed by manual record review. Quality measures were grouped into preprocedure (5), intraprocedure (6), and postprocedure (2). NLP was evaluated using measures of precision and accuracy. RESULTS: A total of 23,674 ERCPs were analyzed (average patient age, 52.9 ± 17.8 years, 14,113 were women [59.6%]). Among 13 quality measures, precision of NLP ranged from 84% to 100% with intraprocedure measures having lower precision (84% for precut sphincterotomy). Accuracy of NLP ranged from 90% to 100% with intraprocedure measures having lower accuracy (90% for pancreatic stent placement). CONCLUSIONS: NLP in conjunction with data mining facilitates individualized tracking of ERCP providers for quality metrics without the need for manual medical record review. Incorporation of these tools across multiple centers may permit tracking of ERCP quality measures through national registries.Item Soft self-expandable metal stent to treat painful pancreatic duct strictures secondary to chronic pancreatitis: a prospective multicenter trial(Elsevier, 2023) Sherman, Stuart; Kozarek, Richard A.; Costamagna, Guido; Reddy, Nageshwar; Tarnasky, Paul; Shah, Raj J.; Slivka, Adam; Fogel, Evan; Watkins, James; Delhaye, Myriam; Irani, Shayan S.; Tringali, Andrea; Lakhtakia, Sundeep; Kedia, Prashant; Edmundowicz, Steven; Peetermans, Joyce A.; Rousseau, Matthew J.; Devière, Jacques; Pancreatic SEMS in Chronic Pancreatitis Study Group; Medicine, School of MedicineBackground and aims: Fully covered self-expandable metal stents (FCSEMSs) may offer a treatment option for pain associated with a dilated pancreatic duct (PD) in chronic pancreatitis (CP), but optimal patient selection and FCSEMS design, efficacy, and safety remain uncertain. We studied an investigational pancreatic FCSEMS for treatment of CP-associated pain. Methods: Patients with painful CP, a dominant distal PD stricture, and PD dilation upstream were enrolled in a prospective, multicenter, single-arm trial studying 6-month indwell of a 4- to 6-cm-long soft pancreatic FCSEMS. Primary efficacy and safety endpoints were pain reduction 6 months after FCSEMS indwell (performance goal ≥53%) and PD stenting-related serious adverse events (SAEs), respectively (performance goal <32%). The primary efficacy endpoint was assessed in patients with sufficiently severe and frequent pain at FCSEMS placement as a first stent or in exchange of a plastic stent. Results: Among 67 patients (mean age, 52.7 ± 12.5 years; mean time since CP diagnosis, 6.4 ± 6.4 years), 34 (50.7%) had plastic stent placement within 90 days of FCSEMS placement, and 46 patients were eligible for the primary efficacy endpoint analysis. Technical success was 97.0% (65/67). The observed primary efficacy (26.1%, 12/46) and safety endpoints (31.3%, 21/67) failed to meet the a priori study hypotheses. Study stent migration occurred in 47.7% of patients (31/65). Conclusions: Six-month treatment with an FCSEMS did not lead to an expected degree of pain reduction, and migrations and SAEs were common. Further study is needed to clarify optimal decompressive strategy, FCSEMS design, and patient selection.