- Browse by Subject
Browsing by Subject "Electrodes"
Now showing 1 - 5 of 5
Results Per Page
Sort Options
Item Accurate and representative decoding of the neural drive to muscles in humans with multi-channel intramuscular thin-film electrodes(Wiley, 2015-09-01) Muceli, Silvia; Poppendieck, Wigand; Negro, Francesco; Yoshida, Ken; Hoffmann, Klaus P.; Butler, Jane E.; Gandevia, Simon C.; Farina, Dario; Department of Biomedical Engineering, School of Engineering and TechnologyIntramuscular electrodes developed over the past 80 years can record the concurrent activity of only a few motor units active during a muscle contraction. We designed, produced and tested a novel multi-channel intramuscular wire electrode that allows in vivo concurrent recordings of a substantially greater number of motor units than with conventional methods. The electrode has been extensively tested in deep and superficial human muscles. The performed tests indicate the applicability of the proposed technology in a variety of conditions. The electrode represents an important novel technology that opens new avenues in the study of the neural control of muscles in humans. We describe the design, fabrication and testing of a novel multi-channel thin-film electrode for detection of the output of motoneurones in vivo and in humans, through muscle signals. The structure includes a linear array of 16 detection sites that can sample intramuscular electromyographic activity from the entire muscle cross-section. The structure was tested in two superficial muscles (the abductor digiti minimi (ADM) and the tibialis anterior (TA)) and a deep muscle (the genioglossus (GG)) during contractions at various forces. Moreover, surface electromyogram (EMG) signals were concurrently detected from the TA muscle with a grid of 64 electrodes. Surface and intramuscular signals were decomposed into the constituent motor unit (MU) action potential trains. With the intramuscular electrode, up to 31 MUs were identified from the ADM muscle during an isometric contraction at 15% of the maximal force (MVC) and 50 MUs were identified for a 30% MVC contraction of TA. The new electrode detects different sources from a surface EMG system, as only one MU spike train was found to be common in the decomposition of the intramuscular and surface signals acquired from the TA. The system also allowed access to the GG muscle, which cannot be analysed with surface EMG, with successful identification of MU activity. With respect to classic detection systems, the presented thin-film structure enables recording from large populations of active MUs of deep and superficial muscles and thus can provide a faithful representation of the neural drive sent to a muscle.Item Mathematical analysis of the lithium ion transport in lithium ion batteries using three dimensional reconstructed electrodes(2012-05) Lim, Cheol Woong; Zhu, Likun; Xie, Jian; Kim, Youngsik; Anwar, SohelComputational analysis of lithium ion batteries has been improved since Newman and et al. suggested the porous electrode theory. It assumed the electrode as a simple structure of homogeneous spherical particles. Bruggeman relationship which characterizes porous material by a simple equation was adopted in the homogeneous electrode model instead of the electrode morphology. To improve the prediction of a cell performance, the numerical analysis requires the realistic microstructure of the cell. Based on the experimentally determined microstructure of the positive and negative electrodes of a lithium ion battery (LIB) using x-ray micro/nano-CT technology, three dimensional (3D) simulations have been presented in this research. Tortuosity of the microstructures has been calculated by a linear diffusion equation to characterize the 3D morphology. The obtained tortuosity and porosity results pointed out that the Bruggeman relationship is not sufficiently estimate the tortuosity by the porosity of electrodes. We studied the diffusion-induced stress numerically based on realistic morphology of reconstructed particles during the lithium ion intercalation process. Diffusion-induced stresses were simulated at different C rates under galvonostatic conditions and compared with spherical particles. The simulation results showed that the intercalation stresses of particles depend on their geometric characteristics. The highest von Mises stress and tresca stress in a real particle are several times higher than the stresses in a spherical particle with the same volume. With the reconstructed positive electrode structure, local effects in the LIB cathode electrode during galvanostatic discharge process have been studied. The simulation results reported that large current density usually occurs at the joints between cathode active material particles and in the small channels in electrolyte, which will generate high electric joule power. By using the 3D real image of a LIB cathode electrode, numerical simulation results revealed that the spatial distribution of variable fields such as concentration, voltage, reaction rate, overpotential, and etc. in the cathode electrode are complicated and non-uniform, especially at high discharge rates.Item Mathematical Model and Experimental Design of Nanocomposite Proximity Sensors(IEEE, 2020-08) Moheimani, Reza; Pasharavesh, Abdolreza; Agarwal, Mangilal; Dalir, Hamid; Engineering Technology, School of Engineering and TechnologyA mathematical model of fringe capacitance for a nano-based proximity sensor, which takes the presence of different resistivities into account, is developed. An analytical solution obtained for a rectangular-shape sensor with applying of Gauss, Conversation of Charge and Ohm laws into Laplace's equation ∇2V (x, y, z, t) = 0 gives the electric potential distribution by which the fringe capacitance in a 2D domain area can be calculated. The calculated capacitance evidently decreases drastically due to the fringe phenomena while object moves toward the polymeric sensor. The model also asserts that the change of capacitance is under a noticeable influence of sensor resistivity, particularly in the range of 103-105Ω.m, the initial capacitance varies from 0.045pF to 0.024 pF. The fabricated flexible nanocomposite sensors, Thermoplastic Polyurethane (TPU) reinforced by 1wt.% Carbon Nanotubes (CNTs) having resistivity 105Ω.m, are capable of detecting presence of an external object in a wide range of distance and indicating remarkable correlation with the mathematical solution. Our proximity sensor fabrication is straightforward and relatively simple. An unprecedented detection range of measurement reveals promising ability of this proximity sensor in applications of motion analysis and healthcare systems.Item Printed Graphene Electrochemical Biosensors Fabricated by Inkjet Maskless Lithography for Rapid and Sensitive Detection of Organophosphates(ACS, 2018-04-04) Hondred, John A.; Breger, Joyce C.; Alves, Nathan J.; Trammell, Scott A.; Walper, Scott A.; Medintz, Igor L.; Claussen, Jonathan C.; Emergency Medicine, School of MedicineSolution phase printing of graphene-based electrodes has recently become an attractive low-cost, scalable manufacturing technique to create in-field electrochemical biosensors. Here, we report a graphene-based electrode developed via inkjet maskless lithography (IML) for the direct and rapid monitoring of triple-O linked phosphonate organophosphates (OPs); these constitute the active compounds found in chemical warfare agents and pesticides that exhibit acute toxicity as well as long-term pollution to soils and waterways. The IML-printed graphene electrode is nano/microstructured with a 1000 mW benchtop laser engraver and electrochemically deposited platinum nanoparticles (dia. ∼25 nm) to improve its electrical conductivity (sheet resistance decreased from ∼10 000 to 100 Ω/sq), surface area, and electroactive nature for subsequent enzyme functionalization and biosensing. The enzyme phosphotriesterase (PTE) was conjugated to the electrode surface via glutaraldehyde cross-linking. The resulting biosensor was able to rapidly measure (5 s response time) the insecticide paraoxon (a model OP) with a low detection limit (3 nM), and high sensitivity (370 nA/μM) with negligible interference from similar nerve agents. Moreover, the biosensor exhibited high reusability (average of 0.3% decrease in sensitivity per sensing event), stability (90% anodic current signal retention over 1000 s), longevity (70% retained sensitivity after 8 weeks), and the ability to selectively sense OP in actual soil and water samples. Hence, this work presents a scalable printed graphene manufacturing technique that can be used to create OP biosensors that are suitable for in-field applications as well as, more generally, for low-cost biosensor test strips that could be incorporated into wearable or disposable sensing paradigms.Item Reversible Nerve Conduction Block Using Low Frequency Alternating Currents(2020-08) Muzquiz, Maria I.; Yoshida, Ken; Schild, John; Berbari, EdThis thesis describes a novel method to reversibly and safely block nerve conduction using a low frequency alternating current (LFAC) waveform at 1 Hz applied through a bipolar extrafascicular electrode. This work follows up on observations made on excised mammalian peripheral nerves and earthworm nerve cords. An in-situ electrophysiology setup was used to assess the LFAC waveform on propagating action potentials (APs) within the cervical vagus nerve in anaesthetized Sprague-Dawley rats (n = 12). Two sets of bipolar cuff or hook electrodes were applied unilaterally to the cervical vagus nerve, which was crushed rostral to the electrodes to exclude reflex effects on the animal. Pulse stimulation was applied to the rostral electrode, while the LFAC conditioning waveform was applied to the caudal electrode. The efferent volley, if unblocked, elicits acute bradycardia and hypotension. The degree of block of the vagal stimulation induced bradycardia was used as a biomarker. Block was assessed by the ability to reduce the bradycardic drive by monitoring the heart rate (HR) and blood pressure (BP) during LFAC alone, LFAC with vagal stimulation, and vagal stimulation alone. LFAC applied via a hook electrode (n = 7) achieved 86.6 +/- 11% block at current levels 95 +/- 38 uAp (current to peak). When applied via a cuff electrode (n = 5) 85.3 +/- 4.60% block was achieved using current levels of 110+/-65 uAp. Furthermore, LFAC was explored on larger vagal afferent fibers in larger human sized nerve bundles projecting to effects mediated by a reflex. The effectiveness of LFAC was assessed in an in-situ electrophysiological setup on the left cervical vagus in anaesthetized domestic swine (n = 5). Two bipolar cuff electrodes were applied unilaterally to the cervical vagus nerve, which was crushed caudal to the electrodes to eliminate cardiac effects. A tripolar extrafascicular cuff electrode was placed most rostral on the nerve for recording of propagating APs induced by electrical stimulation and blocked via the LFAC waveform. Standard pulse stimulation was applied to the left cervical vagus to induce the Hering-Breuer reflex. If unblocked, the activation of the Hering-Breuer reflex would cause breathing to slow down and potentially cease. Block was quantified by the ability to reduce the effect of the Hering-Breuer reflex by monitoring the breathing rate during LFAC alone, LFAC and vagal stimulation, and vagal stimulation alone. LFAC achieved 87.2 +/- 8.8% (n = 5) block at current levels of 0.8 +/- 0.3 mAp. Compound nerve action potentials (CNAP) were monitored directly. They show changes in nerve activity during LFAC, which manifests itself as the slowing and amplitude reduction of components of the CNAPs. Since the waveform is balanced, all forward reactions are reversed, leading to a blocking method that is similar in nature to DC block without the potential issues of toxic byproduct production. These results suggest that LFAC can achieve a high degree of nerve block in both small and large nerve bundles, resulting in the change in behavior of a biomarker, in-vivo in the mammalian nervous system at low amplitudes of electrical stimulation that are within the water window of the electrode.