- Browse by Subject
Browsing by Subject "Electroceutical"
Now showing 1 - 3 of 3
Results Per Page
Sort Options
Item A Highly Miniaturized, Chronically Implanted ASIC for Electrical Nerve Stimulation(IEEE, 2022) Shah, Jay V.; Quinkert, Christopher J.; Collar, Brett J.; Williams, Michael T.; Biggs, Ethan N.; Irazoqui, Pedro P.; Electrical and Computer Engineering, School of Engineering and TechnologyWe present a wireless, fully implantable device for electrical stimulation of peripheral nerves consisting of a powering coil, a tuning network, a Zener diode, selectable stimulation parameters, and a stimulator IC, all encapsulated in biocompatible silicone. A wireless RF signal at 13.56 MHz powers the implant through the on-chip rectifier. The ASIC, designed in TSMC’s 180 nm MS RF G process, occupies an area of less than 1.2 mm2. The IC enables externally selectable current-controlled stimulation through an on-chip read-only memory with a wide range of 32 stimulation parameters (90 – 750 μA amplitude, 100 μs or 1 ms pulse width, 15 or 50 Hz frequency). The IC generates the constant current waveform using an 8-bit binary weighted DAC and an H-Bridge. At the most power-hungry stimulation parameter, the average power consumption during a stimulus pulse is 2.6 mW with a power transfer efficiency of ~5.2%. In addition to benchtop and acute testing, we chronically implanted two versions of the device (a design with leads and a leadless design) on two rats’ sciatic nerves to verify the long-term efficacy of the IC and the full system. The leadless device had the following dimensions: height of 0.45 cm, major axis of 1.85 cm, and minor axis of 1.34 cm, with similar dimensions for the device with leads. Both devices were implanted and worked for experiments lasting from 21–90 days. To the best of our knowledge, the fabricated IC is the smallest constant-current stimulator that has been tested chronically.Item Disposable Patterned Electroceutical Dressing (PED-10) Is Safe for Treatment of Open Clinical Chronic Wounds(Mary Ann Liebert, 2019-04-01) Roy, Sashwati; Prakash, Shaurya; Mathew-Steiner, Shomita S.; Das Ghatak, Piya; Lochab, Varun; Jones, Travis H.; Mohana Sundaram, Prashanth; Gordillo, Gayle M.; Subramaniam, Vish V.; Sen, Chandan K.; Surgery, School of MedicineObjective: To evaluate if patterned electroceutical dressing (PED) is safe for human chronic wounds treatment as reported by wound care providers. Approach: This work reports a pilot feasibility study with the primary objective to determine physically observable effects of PED application on host tissue response from a safety evaluation point of view. For this pilot study, patients receiving a lower extremity amputation with at least one open wound on the part to be amputated were enrolled. Patients were identified through the Ohio State University Wexner Medical Center (OSUWMC) based on inclusion and exclusion criteria through prescreening through the Comprehensive Wound Center's (CWC) Limb Preservation Program and wound physicians and/or providers at OSUWMC. Wounds were treated with the PED before amputation surgery. Results: The intent of the study was to identify if PED was safe for clinical application based on visual observations of adverse or lack of adverse events on skin and wound tissue. The pilot testing performed on a small cohort (N = 8) of patients showed that with engineered voltage regulation of current flow to the open wound, the PED can be used with little to no visually observable adverse effects on chronic human skin wounds. Innovation: The PED was developed as a second-generation tunable electroceutical wound care dressing, which could potentially be used to treat wounds with deeper infections compared with current state of the art that treats wounds with treatment zone limited to the surface near topical application. Conclusion: Technology advances in design and fabrication of electroceutical dressings were leveraged to develop a tunable laboratory prototype that could be used as a disposable low-cost electroceutical wound care dressing on chronic wounds. Design revisions of PED-1 (1 kΩ ballast resistor) circumvented previously observed adverse effects on the skin in the vicinity of an open wound. PED-10 (including a 10 kΩ ballast resistor) was well tolerated in the small cohort of patients (N = 8) on whom it was tested, and the observations reported here warrant a larger study to determine the clinical impact on human wound healing and infection control.Item Electrochemical Devices in Cutaneous Wound Healing(MDPI, 2023-06-11) Evans, J. Parker; Sen, Chandan K.; Surgery, School of MedicineIn healthy skin, vectorial ion transport gives rise to a transepithelial potential which directly impacts many physiological aspects of skin function. A wound is a physical defect that breaches the epithelial barrier and changes the electrochemical environment of skin. Electroceutical dressings are devices that manipulate the electrochemical environment, host as well as microbial, of a wound. In this review, electroceuticals are organized into three mechanistic classes: ionic, wireless, and battery powered. All three classes of electroceutical dressing show encouraging effects on infection management and wound healing with evidence of favorable impact on keratinocyte migration and disruption of wound biofilm infection. This foundation sets the stage for further mechanistic as well as interventional studies. Successful conduct of such studies will determine the best dosage, timing, and class of stimulus necessary to maximize therapeutic efficacy.