- Browse by Author
Browsing by Author "Yadav, Sumit"
Now showing 1 - 5 of 5
Results Per Page
Sort Options
Item Cell and matrix response of temporomandibular cartilage to mechanical loading(Elsevier, 2016-02) Utreja, Achint; Dyment, Nathaniel A.; Yadav, Sumit; Villa, Max M.; Li, Yingcui; Jiang, Xi; Nanda, Ravindra; Rowe, David W.; Department of Orthodontics and Oral Facial Genetics, School of DentistryOBJECTIVES: The generation of transgenic mice expressing green fluorescent proteins (GFPs) has greatly aided our understanding of the development of connective tissues such as bone and cartilage. Perturbation of a biological system such as the temporomandibular joint (TMJ) within its adaptive remodeling capacity is particularly useful in analyzing cellular lineage progression. The objectives of this study were to determine: (i) if GFP reporters expressed in the TMJ indicate the different stages of cell maturation in fibrocartilage and (ii) how mechanical loading affects cellular response in different regions of the cartilage. DESIGN/METHODS: Four-week-old transgenic mice harboring combinations of fluorescent reporters (Dkk3-eGFP, Col1a1(3.6 kb)-GFPcyan, Col1a1(3.6 kb)-GFPtpz, Col2a1-GFPcyan, and Col10a1-RFPcherry) were used to analyze the expression pattern of transgenes in the mandibular condylar cartilage (MCC). To study the effect of TMJ loading, animals were subjected to forced mouth opening with custom springs exerting 50 g force for 1 h/day for 5 days. Dynamic mineralization and cellular proliferation (EdU-labeling) were assessed in loaded vs control mice. RESULTS: Dkk3 expression was seen in the superficial zone of the MCC, followed by Col1 in the cartilage zone, Col2 in the prehypertrophic zone, and Col10 in the hypertrophic zone at and below the tidemark. TMJ loading increased expression of the GFP reporters and EdU-labeling of cells in the cartilage, resulting in a thickness increase of all layers of the cartilage. In addition, mineral apposition increased resulting in Col10 expression by unmineralized cells above the tidemark. CONCLUSION: The TMJ responded to static loading by forming thicker cartilage through adaptive remodeling.Item Histomorphometric and Biomechanical Analyses of Osseointegration of Four Different Orthodontic Mini Implant Surfaces(2011) Yadav, Sumit; Roberts, W. Eugene, Jr.; Chen, Jie; Katona, Thomas R.; Liu, Sean S.; Huja, Sarandeep S. (Sarandeep Singh), 1965-Objective: To evaluate the osseointegration potential of four different surfaces of mini-implants .We hypothesized that mini-implants surface roughness alters the intrinsic biomechanical properties of the bone integrated to titanium. Materials and Methods: Mini implants and circular discs were made from alloy Ti6Al4V grade 5. On the basis of surface treatment study was divided into 4 groups: Group 1: Machined: no surface treatment, Group 2: Acid etched: with hydrochloric acid, Group 3: Grit Blasted with alumina and Group 4: Grit blasted +Acid etched. Surface roughness parameters (mean surface roughness: Ra and Quadratic Average roughness: Rq) of the four discs from each group were measured by the optical profilometer. Contact angle measurement of 3 discs from each group was done with a Goniometer. Contact angle of liquids with different hydrophobicity and hydrophilicity were measured. 128 mini implants, differing in surface treatment, were placed into the tibias and femurs of 8 adult male New Zealand white rabbits. Biomechanical properties (Removal torque and hardness) measurements and histomorphometric observations were measured. Results: Ra and Rq of groups were: Machined (1.17±0.11, 2.59±0.09) Acid etched (1.82±0.04, 3.17±0.13), Grit blasted (4.83±0.23, 7.04±0.08), Grit blasted + Acid etched (3.64±0.03, 4.95±0.04) respectively. Group 4 had significantly (p=0.000) lower Ra and Rq than Group 3. The interaction between the groups and liquid was significant. Group 4 had significantly lower contact angle measurements (40.4°, 26.9°), both for blood and NaCl when compared to other three groups (p≤0.01). Group 4 had significantly higher torque than Group 3 (Tibia: 13.67>9.07N-cm; Femur: 18.21>14.12N-cm), Group 4 (Tibia: 13.67>9.78N-cm; Femur: 18.21>12.87N-cm), and machined (Tibia: 13.67>4.08N-cm; Femur: 18.21>6.49N-cm). SEM analysis reveals significantly more bone implant gap in machined implant surfaces than treated implant surfaces. Bone to implant contact had significantly higher values for treated mini implant surface than machined surface. Hardness of the bone near the implant bone interface is 20 to 25% less hard than bone 1mm away from it in both Femur and Tibia. Conclusion: Surface roughness and wettability of mini implants influences their biological response. Grit blasted and acid etched mini implants had lowest contact angle for different liquids tested and highest removal torques.Item Influence of ceramic (feldspathic) surface treatments on the micro-shear bond strength of composite resin(E.H Angle Education and Research Foundation, 2010-07-01) Yadav, Sumit; Upadhyay, Madhur; Borges, Gilberto Antonio; Roberts, W. Eugene; Orthodontics and Oral Facial Genetics, School of DentistryObjective: To test the null hypothesis that surface treatment has no influence on the micro-shear bond strength between orthodontic composite resin cement and ceramics (feldspathic porcelain). Materials and Methods: Circular specimens of feldspathic porcelain were fabricated and randomly divided into six groups: (1) no treatment; (2) treatment with a mixture of acidic primer and silane agent for 20 seconds; (3) etching with 9.5% hydrofluoric acid; (4) etching with 9.5% hydrofluoric acid and coating with a mixture of acidic primer and silane agent for 20 seconds; (5) airborne-particle abrasion with 50-μm aluminum oxide; and (6) airborne-particle abrasion and coating with a mixture of acidic primer and silane agent for 20 seconds. The porcelain disks were then bonded to resin cylinders with composite resin cement. A micro-shear bond test was carried out to measure the bond strength. Moreover, each ceramic surface was observed morphologically by scanning electron microscopy. One-way analysis of covariance was used to compare the groups for differences in micro-shear bond strength. Results: The mean micro-shear bond strength varied as a function of surface treatment. It ranged from 3.7 to 20.8 MPa. The highest values for micro-shear bond strength were found when the surface was acid-etched with hydrofluoric acid and coated with silane. On the other hand, the control group (no treatment) had significantly lower micro-shear bond strength than all the other groups. Conclusion: The null hypothesis that the surface treatment has no influence on the micro-shear bond strength of orthodontic composite resin was rejected. The bond strength between ceramics and orthodontic resin cement is affected by the ceramic surface treatment. The bond failure was of the adhesive type, except with the hydrofluoric acid + silane group, where it was a cohesive bond failure.Item Integrating skeletal anchorage into fixed and aligner biomechanics(Elsevier, 2022-08) Roberts, W. Eugene; Chang, Chris H.; Chen, Jie; Brezniak, Naphtali; Yadav, Sumit; Mechanical and Energy Engineering, School of Engineering and TechnologyRoutine alignment with fixed appliances and aligners is indeterminate mechanics because equilibrium equations are only applicable to two abutments: teeth, segments, or arches. Orthodontists must depend on compliance and resilience of materials (archwires and aligners) for initial alignment. However, stabilized segments and arches are "large multirooted teeth" that can be moved with determinate mechanics using temporary skeletal anchorage devices. Temporary skeletal anchorage devices have advanced from retromolar implants and inter-radicular miniscrews to extra-alveolar bone screws placed in the basilar bone buccal to the first molars: mandibular buccal shelf and infrazygomatic crest. Extra-alveolar anchorage is determinate mechanics to move teeth, segments, and arches. Retraction and rotation of the lower arch reverses the etiology of Class III open bite malocclusion to correct severe skeletal dysplasia with no extractions or orthognathic surgery.Item Vibrational Force on Accelerating Orthodontic Tooth Movement: A Systematic Review and Meta-Analysis(Thieme, 2022) Akbari, Amin; Gandhi, Vaibhav; Chen, Jie; Turkkahraman, Hakan; Yadav, Sumit; Mechanical and Energy Engineering, School of Engineering and TechnologyThis study aimed to systematically gather and analyze the current level of evidence for the effectiveness of the vibrational force in accelerating orthodontic tooth movement (OTM). This systematic review was conducted using three electronic databases: Scopus, PubMed, and Google Scholar until March 2022. The search was done through the following journals: European Journal of Orthodontics, American Journal of Orthodontics and Dentofacial Orthopedics, The Angle Orthodontist, Progress in Orthodontics, and Seminars in Orthodontics. Human or animal studies that have evaluated the effect of vibrational force on the rate of OTM were selected. A meta-analysis was performed for the rate of canine movement per month. Database research, elimination of duplicate studies, data extraction, and risk of bias assessment were performed by authors independently and in duplication. A fixed and random-effect meta-analysis was performed to evaluate the effect of vibrational forces. A total of 19 studies (6 animal and 13 human studies) that met the inclusion criteria were included. Meta-analysis was performed based on four human clinical trials. Three out of four studies showed no significant difference in the rate of canine movement between vibrational force and control groups. The limitation of this study was the small sample size and significant heterogeneity among the studies. Although vibrational forces have been shown to accelerate OTM in experimental studies, the results are inconsistent in clinical studies. The inability to apply desired peak load to the targeted teeth may be the main factor in inconsistent clinical outcomes.