- Browse by Author
Browsing by Author "Wazni, Oussama M."
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Prognostic value of initial electrocardiography in predicting long-term all-cause mortality in COVID-19(Elsevier, 2022) Kassis, Nicholas; Kumar, Ashish; Gangidi, Shravani; Milinovich, Alex; Kalra, Ankur; Bhargava, Ajay; Menon, Venu; Wazni, Oussama M.; Rickard, John; Khot, Umesh N.; Medicine, School of MedicineBackground: The electrocardiography (ECG) has short-term prognostic value in coronavirus disease 2019 (COVID-19), yet its ability to predict long-term mortality is unknown. This study aimed to elucidate the predictive role of initial ECG on long-term all-cause mortality in patients diagnosed with COVID-19. Methods: In this prospective cohort study, adults with COVID-19 who underwent ECG testing within a 17-hospital health system in Northeast Ohio and Florida between 03/2020-06/2020 were identified. An expert ECG reader analyzed all studies blinded to patient status. The associations of ECG characteristics with long-term all-cause mortality and intensive care unit (ICU) admission were assessed using Cox proportional hazards regression model and multivariable logistic regression models, respectively. Status of long-term mortality was adjudicated on 01/07/2022. Results: Of 837 patients (median age 65 years, 51% female, 44% Black), 683 (81.6%) were hospitalized, 281 (33.6%) required ICU admission, 67 (8.0%) died in-hospital, and 206 (24.6%) died at final follow-up after a median (IQR) of 21 (9-103) days after ECG. Overall, 179 (20.7%) patients presented with sinus tachycardia, 12 (1.4%) with atrial flutter, and 45 (5.4%) with atrial fibrillation (AF). After multivariable adjustment, sinus tachycardia (E-value for HR=3.09, lower CI=2.2) and AF (E-value for HR=3.13, lower CI=2.03) each independently predicted all-cause mortality. At final follow-up, patients with AF had 64.5% probability of death compared with 20.5% for those with normal sinus rhythm (P<.0001). Conclusions: Sinus tachycardia and AF on initial ECG strongly predict long-term all-cause mortality in COVID-19. The ECG can serve as a powerful long-term prognostic tool in COVID-19.Item The degree of permanent pacemaker dependence and clinical outcomes following transcatheter aortic valve implantation: implications for procedural technique(Oxford University Press, 2023-12-04) Dykun, Iryna; Mahabadi, Amir Abbas; Jehn, Stefanie; Kalra, Ankur; Isogai, Toshiaki; Wazni, Oussama M.; Kanj, Mohamad; Krishnaswamy, Amar; Reed, Grant W.; Yun, James J.; Totzeck, Matthias; Jánosi, R. Alexander; Lind, Alexander Y.; Kapadia, Samir R.; Rassaf, Tienush; Puri, Rishi; Medicine, School of MedicineAims: Conduction abnormalities necessitating permanent pacemaker (PPM) implantation remain the most frequent complication post-transcatheter aortic valve implantation (TAVI), yet reliance on PPM function varies. We evaluated the association of right-ventricular (RV)-stimulation rate post-TAVI with 1-year major adverse cardiovascular events (MACE) (all-cause mortality and heart failure hospitalization). Methods and results: This retrospective cohort study of patients undergoing TAVI in two high-volume centers included patients with existing PPM pre-TAVI or new PPM post-TAVI. There was a bimodal distribution of RV-stimulation rates stratifying patients into two groups of either low [≤10%: 1.0 (0.0, 3.6)] or high [>10%: 96.0 (54.0, 99.9)] RV-stimulation rate post-TAVI. Hazard ratios (HR) and 95% confidence intervals (CI) were calculated comparing MACE in patients with high vs. low RV-stimulation rates post-TAVI. Of 4659 patients, 408 patients (8.6%) had an existing PPM pre-TAVI and 361 patients (7.7%) underwent PPM implantation post-TAVI. Mean age was 82.3 ± 8.1 years, 39% were women. A high RV-stimulation rate (>10%) development post-TAVI is associated with a two-fold increased risk for MACE [1.97 (1.20, 3.25), P = 0.008]. Valve implantation depth was an independent predictor of high RV-stimulation rate [odds ratio (95% CI): 1.58 (1.21, 2.06), P=<0.001] and itself associated with MACE [1.27 (1.00, 1.59), P = 0.047]. Conclusion: Greater RV-stimulation rates post-TAVI correlate with increased 1-year MACE in patients with new PPM post-TAVI or in those with existing PPM but low RV-stimulation rates pre-TAVI. A shallower valve implantation depth reduces the risk of greater RV-stimulation rates post-TAVI, correlating with improved patient outcomes. These data highlight the importance of a meticulous implant technique even in TAVI recipients with pre-existing PPMs.