- Browse by Author
Browsing by Author "Stoughton, Christa L."
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Initial Clinical Experience with Swiss LithoClast Trilogy During Percutaneous Nephrolithotomy(Liebert, 2019) Nottingham, Charles U.; Large, Tim; Cobb, Kaitlan; Sur, Roger L.; Canvasser, Noah; Stoughton, Christa L.; Krambeck, Amy E.; Urology, School of MedicineIntroduction and Objective: Current available lithotrites have clinical stone clearance rates averaging 24 to 32 mm2/minute. The objective of this study was to critically evaluate the initial experience with the Swiss LithoClast® Trilogy lithotrite during percutaneous nephrolithotomy (PCNL). Methods: We prospectively enrolled patients with a minimum of 15 mm of stone in axial diameter at three locations (Indiana University, University of California Davis, and University of California San Diego) scheduled to undergo PCNL for nephrolithiasis over a 60-day trial period. We assessed objective measures of stone clearance time, stone clearance rate, device malfunction, stone-free rate, and complications. Each surgeon also evaluated subjective parameters from each case related to the use of Trilogy on a 1 to 10 scale (10 = extremely effective), and compared it with their usual lithotrite on a 1 to 5 scale (5 = much better). Results: We included 43 patients and had 7 bilateral (16.3%) cases, for a total of 50 renal units. One case was a mini-PCNL. Two cases experienced device malfunctions requiring troubleshooting but no transition to another lithotrite. The mean stone clearance rate was 68.9 mm2/minute. The stone-free rate on postoperative imaging was 67.6% (25 of 37 patients with available imaging). The lowest subjective rating was the ergonomic score of 6.7, and the highest subjective rating was the ease of managing settings score of 9.2. The surgeon impressions of ultrasound (7.3), ballistics (8.1), combination of ultrasound and ballistics (8.7), and suction (8.4) were high. One patient experienced an intraoperative renal pelvis perforation, one patient required a blood transfusion, one patient had a pneumothorax requiring chest tube placement, and one patient had a renal artery pseudoaneurysm requiring endovascular embolization. Conclusions: This multi-institutional study evaluated a new and efficient combination lithotrite that was perceived by surgeons to be highly satisfactory, with an excellent safety and durability profile.Item Real-World Experience of Holmium Laser Enucleation of the Prostate with Patients on Anticoagulation Therapy(Liebert, 2021) Agarwal, Deepak K.; Large, Tim; Stoughton, Christa L.; Heiman, Joshua M.; Nottingham, Charles U.; Rivera, Marcelino E.; Krambeck, Amy E.; Urology, School of MedicineBackground: Holmium laser enucleation of the prostate (HoLEP) is a highly effective procedure for benign prostatic hyperplasia that is size independent and has been recommended for patients necessitating antiplatelet (AP) and anticoagulant (AC) medications. Although HoLEP is feasible in AP/AC patients, there is a lack of published results on real-world outcomes of patients on AP/AC therapy undergoing HoLEP. Patients and Methods: We performed a retrospective review of our institutional HoLEP database of demographics, perioperative and postoperative data, and outcomes of patients on AP and AC therapy compared with none. We also further stratified patients on warfarin compared with direct oral anticoagulants (DOACs). Results: Of 472 patients who underwent HoLEP at our institution from July 2018 to December 2019 with data on AP/AC drugs, 30 (6.3%) were on AP and 65 (17.2%) were on AC. One patient continued AP (3.3%), six patients (9.2%) were bridged on AC, and one patient (1.5%) continued AC through the time of HoLEP at the discretion of the prescribing provider. Preoperatively, only age was significantly different among the three groups (p < 0.001). There were no intraoperative differences. Postoperatively, there was a higher 90-day complication rate in AP and AC groups (p = 0.035), but not an increase in emergency department (ED) visits (p = 0.557) or Clavien ≥3 complications (p = 0.16). In comparison of patients on warfarin with DOAC, there was a lower rate of successful voiding trial (p = 0.009), higher 90-day complications (p = 0.003), and more ED visits (p = 0.003) in the warfarin group. Conclusions: HoLEP is safe and effective for patients who require AP or AC therapy. There is no increase in serious complications or worsened postoperative voiding parameters. Of patients on AC, those on DOAC have better outcomes compared with warfarin.