ScholarWorksIndianapolis
  • Communities & Collections
  • Browse ScholarWorks
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Tiếng Việt
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Yкраї́нська
  • Log In
    or
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Shields, Lisa B. E."

Now showing 1 - 7 of 7
Results Per Page
Sort Options
  • Loading...
    Thumbnail Image
    Item
    A Compact Blast-Induced Traumatic Brain Injury Model in Mice
    (Oxford University Press, 2016-02) Wang, Hongxing; Zhang, Yi Ping; Cai, Jun; Shields, Lisa B. E.; Tuchek, Chad A.; Shi, Riyi; Li, Jianan; Shields, Christopher B.; Xu, Xiao-Ming; Neurological Surgery, School of Medicine
    Blast-induced traumatic brain injury (bTBI) is a common injury on the battlefield and often results in permanent cognitive and neurological abnormalities. We report a novel compact device that creates graded bTBI in mice. The injury severity can be controlled by precise pressures that mimic Friedlander shockwave curves. The mouse head was stabilized with a head fixator, and the body was protected with a metal shield; shockwave durations were 3 to 4 milliseconds. Reflective shockwave peak readings at the position of the mouse head were 12 6 2.6 psi, 50 6 20.3 psi, and 100 6 33.1 psi at 100, 200, and 250 psi predetermined driver chamber pressures, respectively. The bTBIs of 250 psi caused 80% mortality, which decreased to 27% with the metal shield. Brain and lung damage depended on the shockwave duration and amplitude. Cognitive deficits were assessed using the Morris water maze, Y-maze, and open-field tests. Pathological changes in the brain included disruption of the blood-brain barrier, multifocal neuronal and axonal degeneration, and reactive gliosis assessed by Evans Blue dye extravasation, silver and Fluoro-Jade B staining, and glial fibrillary acidic protein immunohistochemistry, respectively. Behavioral and pathological changes were injury severity-dependent. This mouse bTBI model may be useful for investigating injury mechanisms and therapeutic strategies associated with bTBI.
  • Loading...
    Thumbnail Image
    Item
    Controlled Cervical Laceration Injury in Mice
    (MyJove, 2013-05-09) Zhang, Yi Ping; Walker, Melissa J.; Shields, Lisa B. E.; Wang, Xiaofei; Walker, Chandler L.; Xu, Xiao-Ming; Shields, Christopher B.; Neurological Surgery, School of Medicine
    Use of genetically modified mice enhances our understanding of molecular mechanisms underlying several neurological disorders such as a spinal cord injury (SCI). Freehand manual control used to produce a laceration model of SCI creates inconsistent injuries often associated with a crush or contusion component and, therefore, a novel technique was developed. Our model of cervical laceration SCI has resolved inherent difficulties with the freehand method by incorporating 1) cervical vertebral stabilization by vertebral facet fixation, 2) enhanced spinal cord exposure, and 3) creation of a reproducible laceration of the spinal cord using an oscillating blade with an accuracy of ± 0.01 mm in depth without associated contusion. Compared to the standard methods of creating a SCI laceration such as freehand use of a scalpel or scissors, our method has produced a consistent lesion. This method is useful for studies on axonal regeneration of corticospinal, rubrospinal, and dorsal ascending tracts.
  • Loading...
    Thumbnail Image
    Item
    Correlation between Electrophysiological Properties, Morphological Maturation, and Olig Gene Changes during Postnatal Motor Tract Development
    (Wiley, 2013) Cai, Jun; Zhang, Yi Ping; Shields, Lisa B. E.; Zhang, Zoe Z.; Lui, Naiqui; Xu, Xiao-Ming; Feng, Shi-Qing; Shields, Christopher B.; Neurological Surgery, School of Medicine
    This study investigated electrophysiological and histological changes as well as alterations of myelin relevant proteins of descending motor tracts in rat pups. Motor-evoked potentials (MEPs) represent descending conducting responses following stimulation of the motor cortex to responses being elicited from the lower extremities. MEP responses were recorded biweekly from postnatal (PN) week 1 to week 9 (adult). MEP latencies in PN week 1 rats averaged 23.7 ms and became shorter during early maturation, stabilizing at 6.6 ms at PN week 4. During maturation, the conduction velocity (CV) increased from 2.8 ± 0.2 at PN week 1 to 35.2 ± 3.1 mm/ms at PN week 8. Histology of the spinal cord and sciatic nerves revealed progressive axonal myelination. Expression of the oligodendrocyte precursor markers PDGFRα and NG2 were downregulated in spinal cords, and myelin-relevant proteins such as GalC, CNP, and MBP increased during maturation. Oligodendrocyte-lineage markers Olig2 and MOG, expressed in myelinated oligodendrocytes, peaked at PN week 3 and were downregulated thereafter. A similar expression pattern was observed in neurofilament M/H subunits that were extensively phosphorylated in adult spinal cords but not in neonatal spinal cords, suggesting an increase in axon diameter and myelin formation. Ultrastructural morphology in the ventrolateral funiculus (VLF) showed axon myelination of the VLF axons (99.3%) at PN week 2, while 44.6% were sheathed at PN week 1. Increased axon diameter and myelin thickness in the VLF and sciatic nerves were highly correlated to the CV (rs > 0.95). This suggests that MEPs could be a predicator of morphological maturity of myelinated axons in descending motor tracts.
  • Loading...
    Thumbnail Image
    Item
    An In Vivo Duo-color Method for Imaging Vascular Dynamics Following Contusive Spinal Cord Injury
    (Journal of Visualized Experiments, 2017-12-31) Chen, Chen; Zhang, Yi Ping; Sun, Yan; Xiong, Wenhui; Shields, Lisa B. E.; Shields, Christopher B.; Jin, Xiaoming; Xu, Xiao-Ming; Neurological Surgery, School of Medicine
    Spinal cord injury (SCI) causes significant vascular disruption at the site of injury. Vascular pathology occurs immediately after SCI and continues throughout the acute injury phase. In fact, endothelial cells appear to be the first to die after a contusive SCI. The early vascular events, including increased permeability of the blood-spinal cord barrier (BSCB), induce vasogenic edema and contribute to detrimental secondary injury events caused by complex injury mechanisms. Targeting the vascular disruption, therefore, could be a key strategy to reduce secondary injury cascades that contribute to histological and functional impairments after SCI. Previous studies were mostly performed on postmortem samples and were unable to capture the dynamic changes of the vascular network. In this study, we have developed an in vivo duo-color two-photon imaging method to monitor acute vascular dynamic changes following contusive SCI. This approach allows detecting blood flow, vessel diameter, and other vascular pathologies at various sites of the same rat pre- and post-injury. Overall, this method provides an excellent venue for investigating vascular dynamics.
  • Loading...
    Thumbnail Image
    Item
    A Novel Vertebral Stabilization Method for Producing Contusive Spinal Cord Injury
    (Jove, 2015-01) Walker, Melissa J.; Walker, Chandler L.; Zhang, Y. Ping; Shields, Lisa B. E.; Shields, Christopher B.; Xu, Xiao-Ming; Department of Anatomy & Cell Biology, IU School of Medicine
    Clinically-relevant animal cervical spinal cord injury (SCI) models are essential for developing and testing potential therapies; however, producing reliable cervical SCI is difficult due to lack of satisfactory methods of vertebral stabilization. The conventional method to stabilize the spine is to suspend the rostral and caudal cervical spine via clamps attached to cervical spinous processes. However, this method of stabilization fails to prevent tissue yielding during the contusion as the cervical spinal processes are too short to be effectively secured by the clamps (Figure 1). Here we introduce a new method to completely stabilize the cervical vertebra at the same level of the impact injury. This method effectively minimizes movement of the spinal column at the site of impact, which greatly improves the production of consistent SCIs. We provide visual description of the equipment (Figure 2-4), methods, and a step-by-step protocol for the stabilization of the cervical 5 vertebra (C5) of adult rats, to perform laminectomy (Figure 5) and produce a contusive SCI thereafter. Although we only demonstrate a cervical hemi-contusion using the NYU/MASCIS impactor device, this vertebral stabilization technique can be applied to other regions of the spinal cord, or be adapted to other SCI devices. Improving spinal cord exposure and fixation through vertebral stabilization may be valuable for producing consistent and reliable injuries to the spinal cord. This vertebral stabilization method can also be used for stereotactic injections of cells and tracers, and for imaging using two-photon microscopy in various neurobiological studies.
  • Loading...
    Thumbnail Image
    Item
    Pathophysiological and behavioral deficits in developing mice following rotational acceleration-deceleration traumatic brain injury
    (Company of Biologists:, 2018-01-30) Wang, Guoxiang; Zhang, Yi Ping; Gao, Zhongwen; Shields, Lisa B. E.; Li, Fang; Chu, Tianci; Lv, Huayi; Moriarty, Thomas; Xu, Xiao-Ming; Yang, Xiaoyu; Shields, Christopher B.; Cai, Jun; Neurological Surgery, School of Medicine
    Abusive head trauma (AHT) is the leading cause of death from trauma in infants and young children. An AHT animal model was developed on 12-day-old mice subjected to 90° head extension-flexion sagittal shaking repeated 30, 60, 80 and 100 times. The mortality and time until return of consciousness were dependent on the number of repeats and severity of the injury. Following 60 episodes of repeated head shakings, the pups demonstrated apnea and/or bradycardia immediately after injury. Acute oxygen desaturation was observed by pulse oximetry during respiratory and cardiac suppression. The cerebral blood perfusion was assessed by laser speckle contrast analysis (LASCA) using a PeriCam PSI system. There was a severe reduction in cerebral blood perfusion immediately after the trauma that did not significantly improve within 24 h. The injured mice began to experience reversible sensorimotor function at 9 days postinjury (dpi), which had completely recovered at 28 dpi. However, cognitive deficits and anxiety-like behavior remained. Subdural/subarachnoid hemorrhage, damage to the brain-blood barrier and parenchymal edema were found in all pups subjected to 60 insults. Proinflammatory response and reactive gliosis were upregulated at 3 dpi. Degenerated neurons were found in the cerebral cortex and olfactory tubercles at 30 dpi. This mouse model of repetitive brain injury by rotational head acceleration-deceleration partially mimics the major pathophysiological and behavioral events that occur in children with AHT. The resultant hypoxia/ischemia suggests a potential mechanism underlying the secondary rotational acceleration-deceleration-induced brain injury in developing mice.
  • Loading...
    Thumbnail Image
    Item
    A Tissue Displacement-based Contusive Spinal Cord Injury Model in Mice
    (JoVE, 2017-06-18) Wu, Xiangbing; Zhang, Yi Ping; Qu, Wenrui; Shields, Lisa B. E.; Shields, Christopher B.; Xu, Xiao-Ming; Neurological Surgery, School of Medicine
    Producing a consistent and reproducible contusive spinal cord injury (SCI) is critical to minimizing behavioral and histological variabilities between experimental animals. Several contusive SCI models have been developed to produce injuries using different mechanisms. The severity of the SCI is based on the height that a given weight is dropped, the injury force, or the spinal cord displacement. In the current study, we introduce a novel mouse contusive SCI device, the Louisville Injury System Apparatus (LISA) impactor, which can create a displacement-based SCI with high injury velocity and accuracy. This system utilizes laser distance sensors combined with advanced software to produce graded and highly-reproducible injuries. We performed a contusive SCI at the 10th thoracic vertebral (T10) level in mice to demonstrate the step-by-step procedure. The model can also be applied to the cervical and lumbar spinal levels.
About IU Indianapolis ScholarWorks
  • Accessibility
  • Privacy Notice
  • Copyright © 2025 The Trustees of Indiana University