- Browse by Author
Browsing by Author "Rondina, Matthew T."
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Contribution of fibrinolysis to the physical component summary of the SF-36 after acute submassive pulmonary embolism(Springer US, 2015-08) Stewart, Lauren K.; Peitz, Geoffrey W.; Nordenholz, Kristen E.; Courtney, D. Mark; Kabrhel, Christopher; Jones, Alan E.; Rondina, Matthew T.; Diercks, Deborah B.; Klinger, James R.; Kline, Jeffrey A.; Department of Emergency Medicine, School of MedicineAcute pulmonary embolism (PE) can diminish patient quality of life (QoL). The objective was to test whether treatment with tenecteplase has an independent effect on a measurement that reflects QoL in patients with submassive PE. This was a secondary analysis of an 8-center, prospective randomized controlled trial, utilizing multivariate regression to control for predefined predictors of worsened QoL including: age, active malignancy, history of PE or deep venous thrombosis (DVT), recurrent PE or DVT, chronic obstructive pulmonary disease and heart failure. QoL was measured with the physical component summary (PCS) of the SF-36. Analysis included 76 patients (37 randomized to tenecteplase, 39 to placebo). Multivariate regression yielded an equation f(8, 67), P<0.001, with R2 = 0.303. Obesity had the largest effect on PCS (β = −8.6, P<0.001), with tenecteplase second (β = 4.73, P = 0.056). After controlling for all interactions, tenecteplase increased the PCS by +5.37 points (P = 0.027). In patients without any of the defined comorbidities, the coefficient on the tenecteplase variable was not significant (−0.835, P = 0.777). In patients with submassive PE, obesity had the greatest influence on QoL, followed by use of fibrinolysis. Fibrinolysis had a marginal independent effect on patient QoL after controlling for comorbidities, but was not significant in patients without comorbid conditions.Item Variable Resistance to Plasminogen Activator Initiated Fibrinolysis for Intermediate-Risk Pulmonary Embolism.(PLOS, 2016) Stubblefield, William B.; Alves, Nathan J.; Rondina, Matthew T.; Kline, Jeffrey A.; Department of Emergency Medicine, IU School of MedicineBackground: We examine the clinical significance and biomarkers of tissue plasminogen activator (tPA)-catalyzed clot lysis time (CLT) in patients with intermediate-risk pulmonary embolism (PE). Methods: Platelet-poor, citrated plasma was obtained from patients with PE. Healthy age- and sex-matched patients served as disease-negative controls. Fibrinogen, α2-antiplasmin, plasminogen, thrombin activatable fibrinolysis inhibitor (TAFI), plasminogen activator Inhibitor 1 (PAI-1), thrombin time and D-dimer were quantified. Clotting was induced using CaCl2, tissue factor, and phospholipid. Lysis was induced using 60 ng/mL tPA. Time to 50% clot lysis (CLT) was assessed by both thromboelastography (TEG) and turbidimetry (A405). Results: Compared with disease-negative controls, patients with PE exhibited significantly longer mean CLT on TEG (+2,580 seconds, 95% CI 1,380 to 3,720 sec). Patients with PE and a short CLT who were treated with tenecteplase had increased risk of bleeding, whereas those with long CLT had significantly worse exercise tolerance and psychometric testing for quality of life at 3 months. A multivariate stepwise removal regression model selected PAI-1 and TAFI as predictive biomarkers of CLT. Conclusion: The CLT from TEG predicted increased risk of bleeding and clinical failure with tenecteplase treatment for intermediate-risk PE. Plasmatic PAI-1 and TAFI were independent predictors of CLT.