- Browse by Author
Browsing by Author "Qi, Yi"
Now showing 1 - 3 of 3
Results Per Page
Sort Options
Item Magic Angle Effect on Diffusion Tensor Imaging in Ligament and Brain(Elsevier, 2022) Wang, Nian; Wen, Qiuting; Maharjan, Surendra; Mirando, Anthony J.; Qi, Yi; Hilton, Matthew J.; Spritzer, Charles E.; Radiology and Imaging Sciences, School of MedicinePurpose: To evaluate the magic angle effect on diffusion tensor imaging (DTI) measurements in rat ligaments and mouse brains. Methods: Three rat knee joints and three mouse brains were scanned at 9.4 T using a modified 3D diffusion-weighted spin echo pulse sequence with the isotropic spatial resolution of 45 μm. The b value was 1000 s/mm2 for rat knee and 4000 s/mm2 for mouse brain. DTI model was used to investigate the quantitative metrics at different orientations with respect to the main magnetic field. The collagen fiber structure of the ligament was validated with polarized light microscopy (PLM) imaging. Results: The signal intensity, signal-to-noise ratio (SNR), and DTI metrics in the ligament were strongly dependent on the collagen fiber orientation with respect to the main magnetic field from both simulation and actual MRI scans. The variation of fractional anisotropy (FA) was about ~32%, and the variation of mean diffusivity (MD) was ~11%. These findings were further validated with the numerical simulation at different SNRs (~10.0 to 86.0). Compared to the ligament, the DTI metrics showed little orientation dependence in mouse brains. Conclusion: Magic angle effect plays an important role in DTI measurements in the highly ordered collagen-rich tissues, while MD showed less orientation dependence than FA.Item Resolution and b value dependent structural connectome in ex vivo mouse brain(Elsevier, 2022) Crater, Stephanie; Maharjan, Surendra; Qi, Yi; Zhao, Qi; Cofer, Gary; Cook, James C.; Johnson, G. Allan; Wang, Nian; Radiology and Imaging Sciences, School of MedicineDiffusion magnetic resonance imaging has been widely used in both clinical and preclinical studies to characterize tissue microstructure and structural connectivity. The diffusion MRI protocol for the Human Connectome Project (HCP) has been developed and optimized to obtain high-quality, high-resolution diffusion MRI (dMRI) datasets. However, such efforts have not been fully explored in preclinical studies, especially for rodents. In this study, high quality dMRI datasets of mouse brains were acquired at 9.4T system from two vendors. In particular, we acquired a high-spatial resolution dMRI dataset (25 μm isotropic with 126 diffusion encoding directions), which we believe to be the highest spatial resolution yet obtained; and a high-angular resolution dMRI dataset (50 μm isotropic with 384 diffusion encoding directions), which we believe to be the highest angular resolution compared to the dMRI datasets at the microscopic resolution. We systematically investigated the effects of three important parameters that affect the final outcome of the connectome: b value (1000s/mm2 to 8000 s/mm2), angular resolution (10 to 126), and spatial resolution (25 µm to 200 µm). The stability of tractography and connectome increase with the angular resolution, where more than 50 angles is necessary to achieve consistent results. The connectome and quantitative parameters derived from graph theory exhibit a linear relationship to the b value (R2 > 0.99); a single-shell acquisition with b value of 3000 s/mm2 shows comparable results to the multi-shell high angular resolution dataset. The dice coefficient decreases and both false positive rate and false negative rate gradually increase with coarser spatial resolution. Our study provides guidelines and foundations for exploration of tradeoffs among acquisition parameters for the structural connectome in ex vivo mouse brain.Item Tractography of Porcine Meniscus Microstructure Using High-Resolution Diffusion Magnetic Resonance Imaging(Frontiers Media, 2022-05-10) Shen, Jikai; Zhao, Qi; Qi, Yi; Cofer, Gary; Johnson, G. Allan; Wang, Nian; Radiology and Imaging Sciences, School of MedicineTo noninvasively evaluate the three-dimensional collagen fiber architecture of porcine meniscus using diffusion MRI, meniscal specimens were scanned using a 3D diffusion-weighted spin-echo pulse sequence at 7.0 T. The collagen fiber alignment was revealed in each voxel and the complex 3D collagen network was visualized for the entire meniscus using tractography. The proposed automatic segmentation methods divided the whole meniscus to different zones (Red-Red, Red-White, and White-White) and different parts (anterior, body, and posterior). The diffusion tensor imaging (DTI) metrics were quantified based on the segmentation results. The heatmap was generated to investigate the connections among different regions of meniscus. Strong zonal-dependent diffusion properties were demonstrated by DTI metrics. The fractional anisotropy (FA) value increased from 0.13 (White-White zone) to 0.26 (Red-Red zone) and the radial diffusivity (RD) value changed from 1.0 × 10-3 mm2/s (White-White zone) to 0.7 × 10-3 mm2/s (Red-Red zone). Coexistence of both radial and circumferential collagen fibers in the meniscus was evident by diffusion tractography. Weak connections were found between White-White zone and Red-Red zone in each part of the meniscus. The anterior part and posterior part were less connected, while the body part showed high connections to both anterior part and posterior part. The tractography based on diffusion MRI may provide a complementary method to study the integrity of meniscus and nondestructively visualize the 3D collagen fiber architecture.