ScholarWorksIndianapolis
  • Communities & Collections
  • Browse ScholarWorks
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Tiếng Việt
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Yкраї́нська
  • Log In
    or
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Orgev, Ahmet"

Now showing 1 - 3 of 3
Results Per Page
Sort Options
  • Loading...
    Thumbnail Image
    Item
    Bead-anchored surgical templates for static computer-assisted implant surgery: A dental technique
    (Wiley, 2022-10) Orgev, Ahmet; Pellerito, John; Polido, Waldemar; Morton, Dean; Lin, Wei-Shao; Prosthodontics, School of Dentistry
    This technique report describes an alternative method to stabilize surgical templates throughout full-arch static computer-assisted implant surgery (FA s-CAIS). In FA s-CAIS, remaining teeth, mucosa, existing implants, custom occlusal device, bone, or any combination thereof, could be used as an initial positioning mechanism to position surgical templates. Different anchoring mechanisms are then used to stabilize the surgical templates during surgery. In this report, a novel design of surgical templates using remaining dentition and opposing occlusal surfaces as initial positioning mechanism followed by the combination of bone block fixation screw and stainless-steel beads as secondary anchoring mechanisms is described. The advantages, limitations, and comparisons with surgical templates using other anchoring mechanisms are also discussed.
  • Loading...
    Thumbnail Image
    Item
    Digital Gothic Arch Tracing Device with Open-Source Software for CAD/CAM Denture Fabrication
    (Quintessence Publishing, 2022) Orgev, Ahmet; Lin, Wei-Shao; Morton, Dean; Prosthodontics, School of Dentistry
    Digital or CAD/CAM workflows and protocols are being increasingly utilized because of their improved efficiency and reproducibility. For the fabrication of complete dentures, digital workflows can reduce treatment time and clinical visits while enhancing the reliability and reproducibility of the laboratory phase and materials. However, establishing centric relation (CR) and vertical dimension of occlusion (VDO) in a reproducible way is still a challenging step for complete denture fabrication in both analog and digital workflows. This clinical report describes a digital workflow utilizing an individualized gothic arch tracing device (GATD) using open-source software for the fabrication of complete dentures. With this workflow, clinicians can offer customized solutions according to patient rehabilitation, with good reproducibility using gothic arch tracing to be implemented in the digital workflow.
  • Loading...
    Thumbnail Image
    Item
    The effects of manufacturing technologies on the surface accuracy of CAD-CAM occlusal splints
    (Wiley, 2022) Orgev, Ahmet; Levon, John A.; Chu, Tien-Min G.; Morton, Dean; Lin, Wei-Shao; Prosthodontics, School of Dentistry
    Purpose To investigate the effects of the manufacturing technologies on the surface (cameo and intaglio) accuracy (trueness and precision) of computer-aided design and computer-aided manufacturing (CAD-CAM) occlusal splints. Materials and methods The digital design of the master occlusal splint was designed in a CAD software program. Six groups (n = 10) were tested in this study, including Group 1 – Milling (Wax), Group 2 – Heat-polymerizing, Group 3 – Milling (M series), Group 4 – Milling (DWX-51/52D), Group 5 – 3D-printing (Cares P30), and Group 6 – 3D-printing (M2). The study samples were placed in a scanning jig fabricated from putty silicone and Type III dental stone. The study samples were then scanned with a laboratory scanner at the intaglio and cameo surfaces, and the scanned files were exported in standard tessellation language (STL) file format. The master occlusal splint STL file, was used as a reference to compare with all scanned samples at the intaglio and cameo surfaces in a surface matching software program. Root mean square (RMS, measured in mm, absolute value) values were calculated by the software for accuracy comparisons. Group means were used as the representation of trueness, and the standard deviation for each group was calculated as a measure of precision. Color maps were recorded to visualize the areas of deviation between study samples and the master occlusal splint file. The data were normalized and transformed to rank scores, and one-way ANOVA was used to test for the differences between the groups. Pairwise comparisons were made between different groups. Fishers least square differences were used to account for the family-wise error rate. A 5% significance level was used for all the tests. Results The null hypotheses were rejected. The manufacturing technologies significantly affected the trueness of occlusal splints at both intaglio and cameo surfaces (p < 0.001). At the cameo surfaces, Group 1 – Milling (Wax) (0.03 ± 0.02 mm), Group 3 – Milling (M series) (0.04 ± 0.01 mm), and Group 4 – Milling (DWX-51/52D) (0.04 ± 0.01 mm) had the smallest mean RMS values and highest trueness. Group 3 had the smallest standard deviation and highest precision among all groups (p < 0.001, except p = 0.005 when compared with Group 2). Group 5 had the largest standard deviation and lowest precision among all groups (p < 0.001). At the intaglio surfaces, Group 1 – Milling (Wax) (0.06 ± 0.01 mm) had the smallest RMS values and highest trueness among all groups (p < 0.001), and Group 2 – Heat-polymerizing (0.20 ± 0.03 mm) and Group 5 – 3D-printing (Cares P30) (0.15 ± 0.05 mm) had significantly larger mean RMS and standard deviation values than all other groups (p < 0.001), with lowest trueness and precision. In the color maps, Group 2 – Heat-polymerizing and Group 5 – 3D-printing (Cares P30) showed the most discrepancies with yellow and red (positive discrepancies) in most areas, and Group 1 – Milling (Wax) showed the best and most uniform surface matching with the most area in green. Conclusion The manufacturing technologies significantly affected the trueness and precision of occlusal splints at both intaglio and cameo surfaces. The 5-axis milling units and industrial-level CLIP 3D-printer could be considered to achieve surface accuracy of occlusal splints.
About IU Indianapolis ScholarWorks
  • Accessibility
  • Privacy Notice
  • Copyright © 2025 The Trustees of Indiana University