- Browse by Author
Browsing by Author "Oberoi, Pankaj"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Guidelines for the standardization of preanalytic variables for blood-based biomarker studies in Alzheimer's disease research(Elsevier, 2015-05) O’Bryant, Sid E.; Gupta, Veer; Henriksen, Kim; Edwards, Melissa; Jeromin, Andreas; Lista, Simone; Bazenet, Chantal; Soares, Holly; Lovestone, Simon; Hampel, Harald; Montine, Thomas; Blennow, Kaj; Foroud, Tatiana; Carrillo, Maria; Graff-Radford, Neill; Laske, Christoph; Breteler, Monique; Shaw, Leslie; Trojanowski, John Q.; Schupf, Nicole; Rissman, Robert A.; Fagan, Anne M.; Oberoi, Pankaj; Umek, Robert; Weiner, Michael W.; Grammas, Paul; Posner, Holly; Martins, Ralph; Department of Medical & Molecular Genetics, IU School of MedicineThe lack of readily available biomarkers is a significant hindrance towards progressing to effective therapeutic and preventative strategies for Alzheimer’s disease (AD). Blood-based biomarkers have potential to overcome access and cost barriers and greatly facilitate advanced neuroimaging and cerebrospinal fluid biomarker approaches. Despite the fact that preanalytical processing is the largest source of variability in laboratory testing, there are no currently available standardized preanalytical guidelines. The current international working group provides the initial starting point for such guidelines for standardized operating procedures (SOPs). It is anticipated that these guidelines will be updated as additional research findings become available. The statement provides (1) a synopsis of selected preanalytical methods utilized in many international AD cohort studies, (2) initial draft guidelines/SOPs for preanalytical methods, and (3) a list of required methodological information and protocols to be made available for publications in the field in order to foster cross-validation across cohorts and laboratories.Item Performance of a Multianalyte 'Rule-Out' Assay in Pregnant Individuals With Suspected Preeclampsia(Wolters Kluwer, 2022) Costantine, Maged M.; Sibai, Baha; Bombard, Allan T.; Sarno, Mark; West, Holly; Haas, David M.; Tita, Alan T.; Paidas, Michael J.; Clark, Erin A. S.; Boggess, Kim; Grotegut, Chad; Grobman, William; Su, Emily J.; Burd, Irina; Saade, George; Chavez, Martin R.; Paglia, Michael J.; Merriam, Audrey; Torres, Carlos; Habli, Mounira; Macones, Georges; Wen, Tony; Bofill, James; Palatnik, Anna; Edwards, Rodney K.; Haeri, Sina; Oberoi, Pankaj; Mazloom, Amin; Cooper, Matthew; Lockton, Steven; Hankins, Gary D.; Obstetrics and Gynecology, School of MedicineBackground: The ability to diagnose preeclampsia clinically is suboptimal. Our objective was to validate a novel multianalyte assay and characterize its performance, when intended for use as an aid to rule-out preeclampsia. Methods: Prospective, multicenter cohort study of pregnant individuals presenting between 280/7 and 366/7 weeks' with preeclampsia-associated signs and symptoms. Individuals not diagnosed with preeclampsia after baseline evaluation were enrolled in the study cohort, with those who later developed preeclampsia, classified as cases and compared with a negative control group who did not develop preeclampsia. Individuals with assay values at time of enrollment ≥0.0325, determined using a previously developed algorithm, considered at risk. The primary analysis was the time to develop preeclampsia assessed using a multivariate Cox regression model. Results: One thousand thirty-six pregnant individuals were enrolled in the study cohort with an incidence of preeclampsia of 30.3% (27.6%-33.2%). The time to develop preeclampsia was shorter for those with an at-risk compared with negative assay result (log-rank P<0.0001; adjusted hazard ratio of 4.81 [3.69-6.27, P<0.0001]). The performance metrics for the assay to rule-out preeclampsia within 7 days of enrollment showed a sensitivity 76.4% (67.5%-83.5%), negative predictive value 95.0% (92.8%-96.6%), and negative likelihood ratio 0.46 (0.32-0.65). Assay performance improved if delivery occurred <37 weeks and for individuals enrolled between 28 and 35 weeks. Conclusions: We confirmed that a novel multianalyte assay was associated with the time to develop preeclampsia and has a moderate sensitivity and negative likelihood ratio but high negative predictive value when assessed as an aid to rule out preeclampsia within 7 days of enrollment.