- Browse by Author
Browsing by Author "Moon, Marc R."
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item A 20-year multicenter analysis of dialysis-dependent patients who had aortic or mitral valve replacement: Implications for valve selection(Elsevier, 2019) Manghelli, Joshua L.; Carter, Daniel I.; Khiabani, Ali J.; Gauthier, Jason M.; Moon, Marc R.; Munfakh, Nabil A.; Damiano, Ralph J.; Corvera, Joel S.; Melby, Spencer J.; Surgery, School of MedicineObjective Valve selection in dialysis-dependent patients can be difficult because long-term survival is diminished and bleeding risks during anticoagulation treatment are greater in patients with renal failure. In this study we analyzed long-term outcomes of dialysis-dependent patients who underwent valve replacement to help guide optimal prosthetic valve type selection. Methods Dialysis-dependent patients who underwent aortic and/or mitral valve replacement at 3 institutions over 20 years were examined. The primary outcome was long-term survival. A Cox regression model was used to estimate survival according to 5 ages, presence of diabetes, and/or heart failure symptoms. Results Four hundred twenty-three available patients were analyzed; 341 patients had biological and 82 had mechanical valves. Overall complication and 30-day mortality rates were similar between the groups. Thirty-day readmission rates for biological and mechanical groups were 15% (50/341) and 28% (23/82; P = .005). Five-year survival was 23% and 33% for the biological and mechanical groups, respectively. After adjusting for age, New York Heart Association (NYHA) class, and diabetes using a multivariable Cox regression model, survival was similar between groups (hazard ratio, 0.93; 95% confidence interval, 0.66-1.29; P = .8). A Cox regression model on the basis of age, diabetes, and heart failure, estimated that patients only 30 or 40 years old, with NYHA class I-II failure without diabetes had a >50% estimated 5-year survival (P < .001). Conclusions Dialysis-dependent patients who underwent valve replacement surgery had poor long-term survival. Young patients without diabetes or NYHA III or IV symptoms might survive long enough to justify placement of a mechanical valve; however, a biological valve is suitable for most patients.Item Evaluating the safety and efficacy of a novel polysaccharide hemostatic system during surgery: A multicenter multispecialty prospective randomized controlled trial(Elsevier, 2024-05-03) House, Michael G.; Kim, Robin; Tseng, Elaine E.; Kaufman, Ronald P., Jr.; Moon, Marc R.; Yopp, Adam; Master, Viraj A.; Surgery, School of MedicineBackground: Operative blood loss is associated with postoperative morbidity and mortality in surgery. Hemostatic agents are used as adjuncts for hemostasis during surgery and help to prevent postoperative bleeding. We evaluated the safety and efficacy of an investigational polysaccharide hemostatic (PH) topical product compared to a U.S. Food and Drug Administration (FDA)-approved control in clinical use comprising microporous polysaccharide hemospheres (MPH) to achieve hemostasis of bleeding surfaces during surgery. Study design: This prospective multicenter trial enrolled patients undergoing open elective cardiac, general, or urologic surgery. Patients were stratified by bleeding severity and therapeutic area, then randomized 1:1 to receive PH or MPH. Bleeding assessments occurred intraoperatively using a novel bleeding assessment methodology. Primary endpoint was noninferiority as compared with control via effective hemostasis at 7 min. Patients were monitored and followed daily in the postoperative period until time of discharge and again at 6 weeks. Overall survival was assessed in oncology patients at 24 months. Safety of PH vs. MPH was determined by comparing relative incidence of adverse events. Results: Across 19 centers, 324 (161 PH, 163 MPH) patients were randomized (48 % general surgery, 27 % cardiac surgery, and 25 % urologic surgery). PH was noninferior to MPH and met the primary endpoint of hemostatic success at 7 min at a non-inferiority margin of 10 %. No significant differences were found in adverse event rates. Six deaths were reported within the 6-week follow-up period. No difference in overall survival was observed at 2 years (76 % PH vs. 74 % MPH, P = .66) for patients undergoing cancer operations. Conclusion: Across three therapeutic areas, PH was noninferior to MPH at all hemostasis assessment time points with no safety concerns. PH is an effective alternative to MPH for hemostasis during surgery.