- Browse by Author
Browsing by Author "McNerny, Erin"
Now showing 1 - 3 of 3
Results Per Page
Sort Options
Item Effects of combination treatment with alendronate and raloxifene on skeletal properties in a beagle dog model(PLOS, 2017-08-09) Allen, Matthew R.; McNerny, Erin; Aref, Mohammad; Organ, Jason M.; Newman, Christopher L.; McGowan, Brian; Jang, Tim; Burr, David B.; Brown, Drew M.; Hammond, Max; Territo, Paul R.; Lin, Chen; Persohn, Scott; Jiang, Lei; Riley, Amanda A.; McCarthy, Brian P.; Hutchins, Gary D.; Wallace, Joseph M.; Anatomy and Cell Biology, School of MedicineA growing number of studies have investigated combination treatment as an approach to treat bone disease. The goal of this study was to investigate the combination of alendronate and raloxifene with a particular focus on mechanical properties. To achieve this goal we utilized a large animal model, the beagle dog, used previously by our laboratory to study both alendronate and raloxifene monotherapies. Forty-eight skeletally mature female beagles (1–2 years old) received daily oral treatment: saline vehicle (VEH), alendronate (ALN), raloxifene (RAL) or both ALN and RAL. After 6 and 12 months of treatment, all animals underwent assessment of bone material properties using in vivo reference point indentation (RPI) and skeletal hydration using ultra-short echo magnetic resonance imaging (UTE-MRI). End point measures include imaging, histomorphometry, and mechanical properties. Bone formation rate was significantly lower in iliac crest trabecular bone of animals treated with ALN (-71%) and ALN+RAL (-81%) compared to VEH. In vivo assessment of properties by RPI yielded minimal differences between groups while UTE-MRI showed a RAL and RAL+ALN treatment regimens resulted in significantly higher bound water compared to VEH (+23 and +18%, respectively). There was no significant difference among groups for DXA- or CT-based measures lumbar vertebra, or femoral diaphysis. Ribs of RAL-treated animals were smaller and less dense compared to VEH and although mechanical properties were lower the material-level properties were equivalent to normal. In conclusion, we present a suite of data in a beagle dog model treated for one year with clinically-relevant doses of alendronate and raloxifene monotherapies or combination treatment with both agents. Despite the expected effects on bone remodeling, our study did not find the expected benefit of ALN to BMD or structural mechanical properties, and thus the viability of the combination therapy remains unclear.Item Reference point indentation is insufficient for detecting alterations in traditional mechanical properties of bone under common experimental conditions(Elsevier, 2016-06) Krege, John B.; Aref, Mohammad W.; McNerny, Erin; Wallace, Joseph M.; Organ, Jason M.; Allen, Matthew R.; Department of Anatomy and Cell Biology, School of MedicineReference point indentation (RPI) was developed as a novel method to assess mechanical properties of bone in vivo, yet it remains unclear what aspects of bone dictate changes/differences in RPI-based parameters. The main RPI parameter, indentation distance increase (IDI), has been proposed to be inversely related to the ability of bone to form/tolerate damage. The goal of this work was to explore the relationshipre-intervention RPI measurebetween RPI parameters and traditional mechanical properties under varying experimental conditions (drying and ashing bones to increase brittleness, demineralizing bones and soaking in raloxifene to decrease brittleness). Beams were machined from cadaveric bone, pre-tested with RPI, subjected to experimental manipulation, post-tested with RPI, and then subjected to four-point bending to failure. Drying and ashing significantly reduced RPI's IDI, as well as ultimate load (UL), and energy absorption measured from bending tests. Demineralization increased IDI with minimal change to bending properties. Ex vivo soaking in raloxifene had no effect on IDI but tended to enhance post-yield behavior at the structural level. These data challenge the paradigm of an inverse relationship between IDI and bone toughness, both through correlation analyses and in the individual experiments where divergent patterns of altered IDI and mechanical properties were noted. Based on these results, we conclude that RPI measurements alone, as compared to bending tests, are insufficient to reach conclusions regarding mechanical properties of bone. This proves problematic for the potential clinical use of RPI measurements in determining fracture risk for a single patient, as it is not currently clear that there is an IDI, or even a trend of IDI, that can determine clinically relevant changes in tissue properties that may contribute to whole bone fracture resistance.Item True Gold or Pyrite: A Review of Reference Point Indentation for Assessing Bone Mechanical Properties In Vivo(Wiley, 2015-09) Allen, Matthew R.; McNerny, Erin; Organ, Jason M.; Wallace, Joseph M.; Department of Anatomy & Cell Biology, IU School of MedicineAlthough the gold standard for determining bones' mechanical integrity is the direct measure of mechanical properties, clinical evaluation has long relied on surrogates of mechanical properties for assessment of fracture risk. Nearly a decade ago, reference point indentation (RPI) emerged as an innovative way to potentially assess mechanical properties of bone in vivo. Beginning with the BioDent device, and then followed by the newer generation OsteoProbe, this RPI technology has been utilized in several publications. In this review we present an overview of the technology and some important details about the two devices. We also highlight select key studies, focused specifically on the in vivo application of these devices, as a way of synthesizing where the technology stands in 2015. The BioDent machine has been shown, in two clinical reports, to be able to differentiate fracture versus nonfracture patient populations and in preclinical studies to detect treatment effects that are consistent with those quantified using traditional mechanical tests. The OsteoProbe appears able to separate clinical cohorts yet there exists a lack of clarity regarding details of testing, which suggests more rigorous work needs to be undertaken with this machine. Taken together, RPI technology has shown promising results, yet much more work is needed to determine if its theoretical potential to assess mechanical properties in vivo can be realized.