- Browse by Author
Browsing by Author "Maxwell, Adam D."
Now showing 1 - 7 of 7
Results Per Page
Sort Options
Item First In-Human Burst Wave Lithotripsy for Kidney Stone Comminution: Initial Two Case Studies(Mary Ann Liebert, Inc., 2021) Harper, Jonathan D.; Metzler, Ian; Hall, Michael Kennedy; Chen, Tony T.; Maxwell, Adam D.; Cunitz, Bryan W.; Dunmire, Barbrina; Thiel, Jeff; Williams, James C., Jr.; Bailey, Michael R.; Sorensen, Mathew D.; Anatomy, Cell Biology and Physiology, School of MedicinePurpose: To test the effectiveness (Participant A) and tolerability (Participant B) of urinary stone comminution in the first-in-human trial of a new technology, burst-wave lithotripsy (BWL). Materials and Methods: An investigational BWL and ultrasonic propulsion system was used to target a 7-mm kidney stone in the operating room before ureteroscopy (Participant A). The same system was used to target a 7.5 mm ureterovesical junction stone in clinic without anesthesia (Participant B). Results: For Participant A, a ureteroscope inserted after 9 minutes of BWL observed fragmentation of the stone to <2 mm fragments. Participant B tolerated the procedure without pain from BWL, required no anesthesia, and passed the stone on day 15. Conclusions: The first-in-human tests of BWL pulses were successful in that a renal stone was comminuted in <10 minutes, and BWL was also tolerated by an awake subject for a distal ureteral stone.Item Fragmentation of Stones by Burst Wave Lithotripsy in the First 19 Humans(Wolters Kluwer, 2022) Harper, Jonathan D.; Lingeman, James E.; Sweet, Robert M.; Metzler, Ian S.; Sunaryo, Peter L.; Williams, James C., Jr.; Maxwell, Adam D.; Thiel, Jeff; Cunitz, Bryan W.; Dunmire, Barbrina; Bailey, Michael R.; Sorensen, Mathew D.; Urology, School of MedicinePurpose: We report stone comminution in the first 19 human subjects by burst wave lithotripsy (BWL), which is the transcutaneous application of focused, cyclic ultrasound pulses. Materials and methods: This was a prospective multi-institutional feasibility study recruiting subjects undergoing clinical ureteroscopy (URS) for at least 1 stone ≤12 mm as measured on computerized tomography. During the planned URS, either before or after ureteroscope insertion, BWL was administered with a handheld transducer, and any stone fragmentation and tissue injury were observed. Up to 3 stones per subject were targeted, each for a maximum of 10 minutes. The primary effectiveness outcome was the volume percent comminution of the stone into fragments ≤2 mm. The primary safety outcome was the independent, blinded visual scoring of tissue injury from the URS video. Results: Overall, median stone comminution was 90% (IQR 20, 100) of stone volume with 21 of 23 (91%) stones fragmented. Complete fragmentation (all fragments ≤2 mm) within 10 minutes of BWL occurred in 9 of 23 stones (39%). Of the 6 least comminuted stones, likely causative factors for decreased effectiveness included stones that were larger than the BWL beamwidth, smaller than the BWL wavelength or the introduction of air bubbles from the ureteroscope. Mild reddening of the papilla and hematuria emanating from the papilla were observed ureteroscopically. Conclusions: The first study of BWL in human subjects resulted in a median of 90% comminution of the total stone volume into fragments ≤2 mm within 10 minutes of BWL exposure with only mild tissue injury.Item Impact of stone type on cavitation in burst wave lithotripsy(Acoustical Society of America, 2018-12-26) Hunter, Christopher; Maxwell, Adam D.; Cunitz, Bryan; Dunmire, Barbrina; Sorensen, Mathew D.; Williams, James C.; Randad, Akshay; Bailey, Michael; Kreider, Wayne; Anatomy and Cell Biology, School of MedicineNon-invasive kidney stone treatments such as shock wave lithotripsy (SWL) and burst wave lithotripsy (BWL) rely on the delivery of pressure waves through tissue to the stone. In both SWL and BWL, the potential to hinder comminution by exciting cavitation proximal to the stone has been reported. To elucidate how different stones alter prefocal cavitation in BWL, different natural and synthetic stones were treated in vitro using a therapy transducer operating at 350 kHz (peak negative pressure 7 MPa, pulse length 20 cycles, pulse repetition frequency 10 Hz). Stones were held in a confined volume of water designed to mimic the geometry of a kidney calyx, with the water filtered and degassed to maintain conditions for which the cavitation threshold (in the absence of a stone) matches that from in vivo observations. Stone targeting and cavitation monitoring were performed via ultrasound imaging using a diagnostic probe aligned coaxially with the therapy transducer. Quantitative differences in the extent and location of cavitation activity were observed for different stone types—e.g., “softer” stones (natural and synthetic) that disintegrate into “dusty” fragments produced larger prefocal cavitation clouds. Future work will focus on correlation of such cavitation metrics with stone fragmentation.Item Improving burst wave lithotripsy effectiveness for small stones and fragments by increasing frequency: theoretical modeling and ex vivo study(Liebert, 2022) Bailey, Michael R.; Maxwell, Adam D.; Cao, Shunxiang; Ramesh, Shivani; Liu, Ziyue; Williams, James Caldwell, Jr.; Thiel, Jeff; Dunmire, Barbrina; Colonius, Tim; Kuznetsova, Ekaterina; Kreider, Wayne; Sorensen, Mathew D.; Lingeman, James E.; Sapozhnikov, Oleg A.; Biostatistics, School of Public HealthIntroduction and Objective: In clinical trial NCT03873259, a 2.6-mm lower pole stone was treated transcutaneously and ex vivo with 390-kHz burst wave lithotripsy (BWL) for 40 minutes and failed to break. The stone was subsequently fragmented with 650-kHz BWL after a 4-minute exposure. This study investigated how to fragment small stones and why varying BWL frequency may more effectively fragment stones to dust. Methods: A linear elastic model was used to calculate the stress created inside stones from shock wave lithotripsy (SWL) and different BWL frequencies mimicking the stone’s size, shape, lamellar structure, and composition. To test model predictions about the impact of BWL frequency, matched pairs of stones (1-5 mm) were treated at 1) 390 kHz, 2) 830 kHz, and 3) 390 kHz followed by 830 kHz. The mass of fragments greater than 1 and 2 mm was measured over 10 minutes of exposure. Results: The linear elastic model predicts that the maximum principal stress inside a stone increases to more than 5.5 times the pressure applied by the ultrasound wave as frequency is increased, regardless of composition tested. The threshold frequency for stress amplification is proportionate to the wave speed divided by the stone diameter. Thus, smaller stones may be likely to fragment at higher frequency, but not lower frequency below a limit. Unlike with SWL, this amplification in BWL occurs consistently with spherical and irregularly shaped stones. In water tank experiments, stones smaller than the threshold size broke fastest at high frequency (p=0.0003), whereas larger stones broke equally well to sub-millimeter dust at high, low, or mixed frequency. Conclusions: For small stones and fragments, increasing frequency of BWL may produce amplified stress in the stone causing the stone to break. Using the strategies outlined here, stones of all sizes may be turned to dust efficiently with BWL.Item In Vitro Evaluation of Urinary Stone Comminution with a Clinical Burst Wave Lithotripsy System(Mary Ann Liebert, Inc., 2020-11) Ramesh, Shivani; Chen, Tony T.; Maxwell, Adam D.; Cunitz, Bryan W.; Dunmire, Barbrina; Thiel, Jeff; Williams, James C., Jr.; Gardner, Anthony; Liu, Ziyue; Metzler, Ian; Harper, Jonathan D.; Sorensen, Mathew D.; Bailey, Michael R.; Anatomy, Cell Biology and Physiology, School of MedicineObjective: Our goals were to validate stone comminution with an investigational burst wave lithotripsy (BWL) system in patient-relevant conditions and to evaluate the use of ultrasonic propulsion to move a stone or fragments to aid in observing the treatment endpoint. Materials and Methods: The Propulse-1 system, used in clinical trials of ultrasonic propulsion and upgraded for BWL trials, was used to fragment 46 human stones (5-7 mm) in either a 15-mm or 4-mm diameter calix phantom in water at either 50% or 75% dissolved oxygen level. Stones were paired by size and composition, and exposed to 20-cycle, 390-kHz bursts at 6-MPa peak negative pressure (PNP) and 13-Hz pulse repetition frequency (PRF) or 7-MPa PNP and 6.5-Hz PRF. Stones were exposed in 5-minute increments and sieved, with fragments >2 mm weighed and returned for additional treatment. Effectiveness for pairs of conditions was compared statistically within a framework of survival data analysis for interval censored data. Three reviewers blinded to the experimental conditions scored ultrasound imaging videos for degree of fragmentation based on stone response to ultrasonic propulsion. Results: Overall, 89% (41/46) and 70% (32/46) of human stones were fully comminuted within 30 and 10 minutes, respectively. Fragments remained after 30 minutes in 4% (1/28) of calcium oxalate monohydrate stones and 40% (4/10) of brushite stones. There were no statistically significant differences in comminution time between the two output settings (p = 0.44), the two dissolved oxygen levels (p = 0.65), or the two calyx diameters (p = 0.58). Inter-rater correlation on endpoint detection was substantial (Fleiss' kappa = 0.638, p < 0.0001), with individual reviewer sensitivities of 95%, 86%, and 100%. Conclusions: Eighty-nine percent of human stones were comminuted with a clinical BWL system within 30 minutes under conditions intended to reflect conditions in vivo. The results demonstrate the advantage of using ultrasonic propulsion to disperse fragments when making a visual determination of breakage endpoint from the real-time ultrasound image.Item An in vivo demonstration of efficacy and acute safety of burst wave lithotripsy using a porcine model(Acoustical Society of America, 2019-02-06) Wang, Yak-Nam; Kreider, Wayne; Hunter, Chris; Cunitz, Bryan W.; Thiel, Jeff; Starr, Frank; Dai, Jessica C.; Nazari, Yasser; Lee, Donghoon; Williams, James C.; Bailey, Micheal R.; Maxwell, Adam D.; Anatomy and Cell Biology, School of MedicineBurst wave lithotripsy (BWL) is a new non-invasive method for stone comminution using bursts of sub-megahertz ultrasound. A porcine model of urolithiasis and techniques to implement BWL treatment has been developed to evaluate its effectiveness and acute safety. Six human calcium oxalate monohydrate stones (6–7 mm) were hydrated, weighed, and surgically implanted into the kidneys of three pigs. Transcutaneous stone treatments were performed with a BWL transducer coupled to the skin via an external water bath. Stone targeting and treatment monitoring were performed with a co-aligned ultrasound imaging probe. Treatment exposures were applied in three 10-minute intervals for each stone. If sustained cavitation in the parenchyma was observed by ultrasound imaging feedback, treatment was paused and the pressure amplitude was decreased for the remaining time. Peak negative focal pressures between 6.5 and 7 MPa were applied for all treatments. After treatment, stone fragments were removed from the kidneys. At least 50% of each stone was reduced to <2 mm fragments. 100% of four stones were reduced to <4 mm fragments. Magnetic resonance imaging showed minimal injury to the functional renal volume. This study demonstrated that BWL could be used to effectively fragment kidney stones with minimal injury.Item Update on clinical trials of kidney stone repositioning and preclinical results of stone breaking with one system(Acoustical Society of America, 2018-12-21) Bailey, Michael R.; Wang, Yak-Nam; Kreider, Wayne; Dai, Jessica C.; Cunitz, Bryan W.; Harper, Jonathan D.; Chang, Helena; Sorensen, Mathew D.; Liu, Ziyue; Levy, Oren; Dunmire, Barbrina; Maxwell, Adam D.; Biostatistics, School of Public HealthOur goal is an office-based, handheld ultrasound system to target, detach, break, and/or expel stones and stone fragments from the urinary collecting system to facilitate natural clearance. Repositioning of stones in humans (maximum 2.5 MPa, and 3-second bursts) and breaking of stones in a porcine model (maximum 50 cycles, 20 Hz repetition, 30 minutes, and 7 MPa peak negative pressure) have been demonstrated using the same 350-kHz probe. Repositioning in humans was conducted during surgery with a ureteroscope in the kidney to film stone movement. Independent video review confirmed stone movements (≥ 3 mm) in 15 of 16 kidneys (94%). No serious or unanticipated adverse events were reported. Experiments of burst wave lithotripsy (BWL) effectiveness on breaking human stones implanted in the porcine bladder and kidney demonstrated fragmentation of 8 of 8 stones on post mortem dissection. A 1-week survival study with the BWL exposures and 10 specific-pathogen-free pigs, showed all findings were within normal limits on clinical pathology, hematology, and urinalysis. These results demonstrate that repositioning of stones with ultrasonic propulsion and breaking of stones with BWL are safe and effective.