- Browse by Author
Browsing by Author "Masterson, Adrianna N."
Now showing 1 - 8 of 8
Results Per Page
Sort Options
Item Bottom-Up Fabrication of Plasmonic Nanoantenna-Based High-throughput Multiplexing Biosensors for Ultrasensitive Detection of microRNAs Directly from Cancer Patients’ Plasma(ACS, 2020) Masterson, Adrianna N.; Liyanage, Thakshila; Kaimakliotis, Hristos; Derami, Hamed Gholami; Deiss, Frédérique; Sardar, Rajesh; Chemistry and Chemical Biology, School of ScienceThere is an unmet need in clinical point-of-care (POC) cancer diagnostics for early state disease detection, which would greatly increase patient survival rates. Currently available analytical techniques for early stage cancer diagnosis do not meet the requirements for POC of a clinical setting. They are unable to provide the high demand of multiplexing, high-throughput, and ultrasensitive detection of biomarkers directly from low volume patient samples (“liquid biopsy”). To overcome these current technological bottle-necks, herein we present, for the first time, a bottom-up fabrication strategy to develop plasmonic nanoantenna-based sensors that utilize the unique localized surface plasmon resonance (LSPR) properties of chemically synthesized gold nanostructures, gold triangular nanoprisms (Au TNPs), gold nanorods (Au NRs), and gold spherical nanoparticles (Au SNPs). Our Au TNPs, NRs, and SNPs display refractive index unit (RIU) sensitivities of 318, 225, and 135 nm/RIU respectively. Based on the RIU results, we developed plasmonic nanoantenna-based multiplexing and high-throughput biosensors for the ultrasensitive assay of microRNAs. MicroRNAs are directly linked with cancer development, progression, and metastasis, thus they hold promise as next generation biomarkers for cancer diagnosis and prognosis. The developed biosensors are capable of assaying five different types of microRNAs at an attomolar detection limit. These sets of microRNAs include both oncogenic and tumor suppressor microRNAs. To demonstrate the efficiency as a POC cancer diagnostic tool, we analyzed the plasma of 20-bladder cancer patients without any sample processing steps. Importantly, our liquid biopsy-based biosensing approach is capable of differentiating healthy from early (“non-metastatic”) and late (“metastatic”) stage cancer with a p value <0.0001. Further, receiver operating characteristic analysis shows that our biosensing approach is highly specific, with an area under the curve of 1.0. Additionally, our plasmonic nanoantenna-based biosensors are regenerative, allowing multiple measurements using the same biosensors, which is essential in low- and middle-income countries. Taken together, our multiplexing and high-throughput biosensors have the unmatched potential to advance POC diagnostics and meet global needs for early stage detection of cancer and other diseases (e.g., infectious, autoimmune, and neurogenerative diseases).Item Covalent Surface Modification of Ti3C2Tx MXene with Chemically Active Polymeric Ligands Producing Highly Conductive and Ordered Microstructure Films(American Chemical Society (ACS), 2021-11-17) Lee, Jacob T.; Wyatt, Brian C.; Davis, Gregory A., Jr.; Masterson, Adrianna N.; Pagan, Amber L.; Shah, Archit; Anasori, Babak; Sardar, Rajesh; Chemistry, School of ScienceAs interest continues to grow in Ti3C2Tx and other related MXenes, advancement in methods of manipulation of their surface functional groups beyond synthesis-based surface terminations (Tx: −F, −OH, and ═O) can provide mechanisms to enhance solution processability as well as produce improved solid-state device architectures and coatings. Here, we report a chemically important surface modification approach in which “solvent-like” polymers, polyethylene glycol carboxylic acid (PEG6-COOH), are covalently attached onto MXenes via esterification chemistry. Surface modification of Ti3C2Tx with PEG6-COOH with large ligand loading (up to 14% by mass) greatly enhances dispersibility in a wide range of nonpolar organic solvents (e.g., 2.88 mg/mL in chloroform) without oxidation of Ti3C2Tx two-dimensional flakes or changes in the structure ordering. Furthermore, cooperative interactions between polymer chains improve the nanoscale assembly of uniform microstructures of stacked MXene-PEG6 flakes into ordered thin films with excellent electrical conductivity (∼16,200 S·cm–1). Most importantly, our covalent surface modification approach with ω-functionalized PEG6 ligands (ω-PEG6-COOH, where ω: −NH2, −N3, −CH═CH2) allows for control over the degree of functionalization (incorporation of valency) of MXene. We believe that installing valency onto MXenes through short, ion conducting PEG ligands without compromising MXenes’ features such as solution processability, structural stability, and electrical conductivity further enhance MXenes surface chemistry tunability and performance and widens their applications.Item Enhancing Nonfouling and Sensitivity of Surface-Enhanced Raman Scattering Substrates for Potent Drug Analysis in Blood Plasma via Fabrication of a Flexible Plasmonic Patch(ACS, 2021-01) Masterson, Adrianna N.; Hati, Sumon; Ren, Greta; Liyanage, Thakshila; Manicke, Nicholas E.; Goodpaster, John V.; Sardar, Rajesh; Chemistry and Chemical Biology, School of ScienceSurface-enhanced Raman scattering (SERS) is an ultrasensitive analytical technique, which is capable of providing high specificity; thus, it can be used for toxicological drug assay (detection and quantification). However, SERS-based drug analysis directly in human biofluids requires mitigation of fouling and nonspecificity effects that commonly appeared from unwanted adsorption of endogenous biomolecules present in biofluids (e.g., blood plasma and serum) onto the SERS substrate. Here, we report a bottom-up fabrication strategy to prepare ultrasensitive SERS substrates, first, by functionalizing chemically synthesized gold triangular nanoprisms (Au TNPs) with poly(ethylene glycol)-thiolate in the solid state to avoid protein fouling and second, by generating flexible plasmonic patches to enhance SERS sensitivity via the formation of high-intensity electromagnetic hot spots. Poly(ethylene glycol)-thiolate-functionalized Au TNPs in the form of flexible plasmonic patches show a twofold-improved signal-to-noise ratio in comparison to triethylamine (TEA)-passivated Au TNPs. Furthermore, the plasmonic patch displays a SERS enhancement factor of 4.5 ×107. Utilizing the Langmuir adsorption model, we determine the adsorption constant of drugs for two different surface ligands and observe that the drug molecules display stronger affinity for poly(ethylene glycol) ligands than TEA. Our density functional theory calculations unequivocally support the interaction between drug molecules and poly(ethylene glycol) moieties. Furthermore, the universality of the plasmonic patch for SERS-based drug detection is demonstrated for cocaine, JWH-018, and opioids (fentanyl, despropionyl fentanyl, and heroin) and binary mixture (trace amount of fentanyl in heroin) analyses. We demonstrate the applicability of flexible plasmonic patches for the selective assay of fentanyl at picogram/milliliter concentration levels from drug-of-abuse patients’ blood plasma. The fentanyl concentration calculated in the patients’ blood plasma from SERS analysis is in excellent agreement with the values determined using the paper spray ionization mass spectrometry technique. We believe that the flexible plasmonic patch fabrication strategy would be widely applicable to any plasmonic nanostructure for SERS-based chemical sensing for clinical toxicology and therapeutic drug monitoring.Item Gabapentin Disrupts Binding of Perlecan to the α2δ1 Voltage Sensitive Calcium Channel Subunit and Impairs Skeletal Mechanosensation(MDPI, 2022-12-12) Reyes Fernandez, Perla C.; Wright, Christian S.; Masterson, Adrianna N.; Yi, Xin; Tellman, Tristen V.; Bonteanu, Andrei; Rust, Katie; Noonan, Megan L.; White, Kenneth E.; Lewis, Karl J.; Sankar, Uma; Hum, Julia M.; Bix, Gregory; Wu, Danielle; Robling, Alexander G.; Sardar, Rajesh; Farach-Carson, Mary C.; Thompson, William R.; Physical Therapy, School of Health and Human SciencesOur understanding of how osteocytes, the principal mechanosensors within bone, sense and perceive force remains unclear. Previous work identified "tethering elements" (TEs) spanning the pericellular space of osteocytes and transmitting mechanical information into biochemical signals. While we identified the heparan sulfate proteoglycan perlecan (PLN) as a component of these TEs, PLN must attach to the cell surface to induce biochemical responses. As voltage-sensitive calcium channels (VSCCs) are critical for bone mechanotransduction, we hypothesized that PLN binds the extracellular α2δ1 subunit of VSCCs to couple the bone matrix to the osteocyte membrane. Here, we showed co-localization of PLN and α2δ1 along osteocyte dendritic processes. Additionally, we quantified the molecular interactions between α2δ1 and PLN domains and demonstrated for the first time that α2δ1 strongly associates with PLN via its domain III. Furthermore, α2δ1 is the binding site for the commonly used pain drug, gabapentin (GBP), which is associated with adverse skeletal effects when used chronically. We found that GBP disrupts PLN::α2δ1 binding in vitro, and GBP treatment in vivo results in impaired bone mechanosensation. Our work identified a novel mechanosensory complex within osteocytes composed of PLN and α2δ1, necessary for bone force transmission and sensitive to the drug GBP.Item Multiplexed and High-Throughput Label-Free Detection of RNA/Spike Protein/IgG/IgM Biomarkers of SARS-CoV-2 Infection Utilizing Nanoplasmonic Biosensors(American Chemical Society, 2021-06-29) Masterson, Adrianna N.; Muhoberac, Barry B.; Gopinadhan, Adnan; Wilde, David J.; Deiss, Frédérique T.; John, Chandy C.; Sardar, Rajesh; Chemistry and Chemical Biology, School of ScienceTo tackle the COVID-19 outbreak, which is caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), there is an unmet need for highly accurate diagnostic tests at all stages of infection with rapid results and high specificity. Here, we present a label-free nanoplasmonic biosensor-based, multiplex screening test for COVID-19 that can quantitatively detect 10 different biomarkers (6 viral nucleic acid genes, 2 spike protein subunits, and 2 antibodies) with a limit of detection in the aM range, all within one biosensor platform. Our newly developed nanoplasmonic biosensors demonstrate high specificity, which is of the upmost importance to avoid false responses. As a proof of concept, we show that our detection approach has the potential to quantify both IgG and IgM antibodies directly from COVID-19-positive patient plasma samples in a single instrument run, demonstrating the high-throughput capability of our detection approach. Most importantly, our assay provides receiving operating characteristics, areas under the curve of 0.997 and 0.999 for IgG and IgM, respectively. The calculated p-value determined through the Mann-Whitney nonparametric test is <0.0001 for both antibodies when the test of COVID-19-positive patients (n = 80) is compared with that of healthy individuals (n = 72). Additionally, the screening test provides a calculated sensitivity (true positive rate) of 100% (80/80), a specificity (true negative rate) >96% (77/80), a positive predictive value of 98% at 5% prevalence, and a negative predictive value of 100% at 5% prevalence. We believe that our very sensitive, multiplex, high-throughput testing approach has potential applications in COVID-19 diagnostics, particularly in determining virus progression and infection severity for clinicians for an appropriate treatment, and will also prove to be a very effective diagnostic test when applied to diseases beyond the COVID-19 pandemic.Item A Novel Liquid Biopsy-Based Approach for Highly Specific Cancer Diagnostics: Mitigating False Responses in Assaying Patient Plasma-Derived Circulating microRNAs through Combined SERS and Plasmon-Enhanced Fluorescence Analyses(RSC, 2020) Masterson, Adrianna N.; Liyanage, Thakshila; Berman, Claire; Kaimakliotis, Hristos; Johnson, Merrell; Sardar, Rajesh; Chemistry and Chemical Biology, School of ScienceStudies have shown that microRNAs, which are small noncoding RNAs, hold tremendous promise as next-generation circulating biomarkers for early cancer detection via liquid biopsies. A novel, solid-state nanoplasmonic sensor capable of assaying circulating microRNAs through a combined surface-enhanced Raman scattering (SERS) and plasmon-enhanced fluorescence (PEF) approach has been developed. Here, the unique localized surface plasmon resonance properties of chemically-synthesized gold triangular nanoprisms (Au TNPs) are utilized to create large SERS and PEF enhancements. With careful modification to the surface of Au TNPs, this sensing approach is capable of quantifying circulating microRNAs at femtogram/microliter concentrations. Uniquely, the multimodal analytical methods mitigate both false positive and false negative responses and demonstrate the high stability of our sensors within bodily fluids. As a proof of concept, microRNA-10b and microRNA-96 were directly assayed from the plasma of six bladder cancer patients. Results show potential for a highly specific liquid biopsy method that could be used in point-of-care clinical diagnostics to increase early cancer detection or any other diseases including SARS-CoV-2 in which RNAs can be used as biomarkers.Item Plasmoelectronic-Based Ultrasensitive Assay of Tumor Suppressor microRNAs Directly in Patient Plasma: Design of Highly Specific Early Cancer Diagnostic Technology(ACS, 2019) Liyanage, Thakshila; Masterson, Adrianna N.; Oyem, Hector H.; Kaimakliotis, Hristos; Nguyen, Hang; Sardar, Rajesh; Chemistry and Chemical Biology, School of ScienceIt is becoming understood that microRNAs hold great promise for noninvasive liquid biopsies for screening for different types of cancer, but current state-of-the-art RT-PCR and microarray techniques have sensitivity limitations that currently restrict their use. Herein, we report a new transduction mechanism involving delocalization of photoexcited conduction electrons wave function of gold triangular nanoprism (Au TNP) in the presence of -ssDNA/microRNA duplexes. This plasmoelectronic effect increases the electronic dimension of Au TNPs and substantially affects their localized surface plasmon resonance (LSPR) properties that together allow us to achieve a sensitivity for microRNA assay as low as 140 zeptomolar concentrations for our nanoplasmonic sensors. We show that the position of a single base-pair mismatch in the -ssDNA/microRNA duplex dramatically alters the LSPR properties and detection sensitivity. The unprecedentedly high sensitivity of nanoplasmonic sensors has allowed us to assay four different microRNAs (microRNA-10b, -182, -143, and -145) from bladder cancer patient plasma (50 μL/sample). For the first time, we demonstrate the utility of a label-free, nanoplasmonic sensor in quantification of tumor suppressor microRNAs, the level of tumor suppressor microRNAs goes down in a cancer patient as compared to normal healthy individuals, in metastatic and nonmetastatic bladder cancer patient plasma. Our statistical analysis of patient samples unequivocally suggests that the tumor suppressor microRNAs are more specific biomarkers (p-value of <0.0001) than oncogenic microRNAs for differentiation between metastatic and nonmetastatic bladder cancer, and nonmetastatic cancer from healthy individuals. This work demonstrating the electron wave functions delocalization dependent ultrasensitive LSPR properties of noble metal nanoparticles has a great potential for fabrication of miniaturized and extremely powerful sensors to investigate microRNA properties in other cancers (for example breast, lung, and pancreatic) through liquid biopsy.Item Selective Detection and Ultrasensitive Quantification of SARS-CoV-2 IgG Antibodies in Clinical Plasma Samples Using Epitope-Modified Nanoplasmonic Biosensing Platforms(American Chemical Society, 2022-05-31) Masterson, Adrianna N.; Sardar, Rajesh; Chemistry and Chemical Biology, School of ScienceMonitoring the human immune response by assaying (detection and quantification) the antibody level against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is important in conducting epidemiological surveillance and immunization studies at a population level. Herein, we present the design and fabrication of a solid-state nanoplasmonic biosensing platform that is capable of quantifying SARS-CoV-2 neutralizing antibody IgG with a limit of detection as low as 30.0 attomolar (aM) and a wide dynamic range spanning seven orders of magnitude. Based on IgG binding constant determination for different biological motifs, we show that the covalent attachment of highly specific SARS-CoV-2 linear epitopes with an appropriate ratio, in contrast to using SARS-CoV-2 spike protein subunits as receptor molecules, to gold triangular nanoprisms (Au TNPs) results in a construction of a highly selective and more sensitive, label-free IgG biosensor. The biosensing platform displays specificity against other human antibodies and no cross reactivity against MERS-CoV antibodies. Furthermore, the nanoplasmonic biosensing platform can be assembled in a multi-well plate format to translate to a high-throughput assay that allowed us to conduct SARS-CoV-2 IgG assays of COVID-19 positive patient (n = 121) and healthy individual (n = 65) plasma samples. Most importantly, performing a blind test in an additional cohort of 30 patient plasma samples, our nanoplasmonic biosensing platform successfully identified COVID-19 positive samples with 90% specificity and 100% sensitivity. Very recent studies show that our selected epitopes are conserved in the highly mutated SARS-CoV-2 variant "Omicron"; therefore, the demonstrated high-throughput nanoplasmonic biosensing platform holds great promise for a highly specific serological assay for conducting large-scale COVID-19 testing and epidemiological studies and monitoring the immune response and durability of immunity as part of the global immunization programs.