- Browse by Author
Browsing by Author "Lund, Melvin R., 1922-"
Now showing 1 - 4 of 4
Results Per Page
Sort Options
Item The effect of full-contour Y-TZP ceramic surface roughness on the wear of bovine enamel and synthetic hydroxyapatite : an in-vitro study(2011) Sabrah, Alaá Hussein Aref, 1984-; Bottino, Marco C.; Lund, Melvin R., 1922-; Cochran, Michael A. (Michael Alan), 1944-; Hara, Anderson T.; Cook, Norman Blaine, 1954-THE EFFECT OF FULL-CONTOUR Y-TZP CERAMIC SURFACE ROUGHNESS ON THE WEAR OF BOVINE ENAMEL AND SYNTHETIC HYDROXYAPATITE: AN IN-VITRO STUDY by Alaa Hussein Aref Sabrah Indiana University School of Dentistry Indianapolis, Indiana Full-contour yttrium-stabilized tetragonal zirconia polycrystal (Y-TZP) restorations have been advocated recently in clinical situations where occlusal/palatal space is limited, or to withstand parafunctional activities. The objectives of this in-vitro study were to investigate the effects of different polishing techniques on the surface roughness of Y-TZP (Ardent Dental, Inc.) and to investigate the effects of different polishing techniques on the wear behavior of synthetic hydroxyapatite (HA) and bovine enamel. An in-vitro study was conducted by fabrication of 48 Y-TZP sliders (diameter = 2 mm × 1.5 mm in height) using CAD/CAM technique; then the samples were embedded in acrylic resin using brass holders. Samples were then randomly allocated into four groups according to the finishing/polishing procedure: G1-as-machined (n = 8), G2- glazed (n = 16), G3-diamond bur-finishing (Brasseler, USA) (n = 8) and G4- G3+OptraFine polishing kit (Ivoclar-Vivadent) (n = 16). Thirty-two sintered HA disks (diameter = 11 mm × 2.9 mm in height) and 16 bovine enamel samples with a minimum surface area of 64 mm2 were mounted in brass holders. Baseline surface roughness (Ra and Rq, in μm) were recorded using a non-contact profilometer (Proscan 2000) for all the samples. A two-body pin-on-disk wear test was performed for 25,000 cycles at 1.2 Hz in which the four zirconia groups were tested against HA, and only G2-glazed and G4- G3+OptraFine polishing kit (Ivoclar-Vivadent) were tested against bovine enamel. Vertical substance loss (μm) and volume loss (mm3) of HA were measured (Proscan). Zirconia height loss was measured using a digital micrometer. One-way ANOVA was used for statistical analysis. The results indicated that surface roughness measurements showed significant differences among the surface treatments with G1 (Ra = 0.84, Rq = 1.13 μm) and G3 (Ra = 0.89, Rq = 1.2 μm) being the roughest, and G2 (Ra = 0.42, Rq = 0.63 μm) the smoothest. The glazed group showed the highest vertical loss (35.39 μm) suggesting wear of the glaze layer, while the polished group showed the least vertical loss (6.61 μm). HA antagonist volume loss and vertical height loss for groups (G1, G2 and G3) were similar, while polished group (1.3 mm3, 14.7 μm) showed significant lower (p = 0.0001) values. Antagonist height loss and antagonist volume loss were significantly higher for bovine antagonist than for HA antagonist (197.6 μm/116.2 μm, and 28.5 mm3/17.7 mm3 for bovine against glazed/polished zirconia sliders, respectively) (p < 0.0001). From the results it can be concluded that glazed zirconia provided an initially smooth surface, but a significant increased antagonist wear compared with the polished surface was seen. Bovine enamel showed higher wear compared with HA, which suggested that more studies should be performed to validate the use of bovine enamel as a substitute for human enamel in wear studies.Item Evaluation of water sorption and solubility behavior of nine different polymeric luting materials(2009) Alsheikh, Rasha N.; Platt, Jeffrey A.; Lund, Melvin R., 1922-; Cochran, Michael A. (Michael Alan), 1944-; Moore, B. Keith; Matis, Bruce A.The cementation procedure is the key to long-term success of fixed restorations. The prognosis of prosthetic restoration is largely impacted by the maintenance of the luting cement and the adhesive bond. When exposed to water or saliva, most restorative materials undergo hydrolytic degradation. The purpose of this study is to evaluate the water solubility and water sorption characteristics of newly introduced acidic polymeric luting agents over a 180-day water-storage period. Nine different luting agents were tested. Fifty-two disc specimens of each material were fabricated using a mold with an internal dimension of 15[plus-minus]0.1 mm in diameter and 1.0 [plus-minus]0.1 mm deep. A constant weight, W0 [subscript zero], was reached after desiccating the specimens. Then, 13 specimens were assigned randomly to one of the four testing periods in the water for seven, 30, 90 and 180 days. After each period, the specimens were removed from the water and weighed to get W1 [subscript one]. A second period of desiccating the samples provided a constant weight W2 [subscript two]. The water sorption and solubility were determined by the following equations: WSP [subscript SP](%) = (W1 [subscript one] W2 [subscript two] ) X 100/ W0 [subscript zero] ,WSL [subscript SL](%) = (W0 [subscript zero] W2 [subscript two) X 100/ W0 [subscript zero]. The resin-modified glass-ionomers showed the highest water sorption/solubility results. The resin luting agents had the lowest sorption/solubility results. The self-adhesives showed a wide range of solubility/sorption; in general, they showed lower results compared with the resin-modified glass-ionomers. All the materials reached some sort of equilibrium after 90-days. Based on the results of our study, we conclude that self-adhesive luting materials were not all alike. Rely X Unicem was the most comparable to the resin luting materials. The resin luting materials had the lowest solubility and sorption. Resin-modified glass-ionomers showed the highest sorption/solubility results.Item The ion release behaviours and water sorption of novel resin-based calcium phosphate cement(2010) AlZain, Afnan Omar, 1981-; Chu, Tien-Min Gabriel; Lund, Melvin R., 1922-; Cochran, Michael A. (Michael Alan), 1944-; Martinez Mier, Esperanza de los A. (Esperanza de los Angeles), 1967-; Cook, Norman Blaine, 1954-Calcium phosphate-filled restorative materials were developed to provide calcium (Ca) and phosphate (PO4) ions, which have been proposed to enhance remineralization of demineralized tooth structure. Recently, tricalcium phosphate (TCP)-filled restorative materials were introduced as an alternative to amorphous calcium phosphate. The TCP filler has a more crystalline structure than ACP and is therefore potentially stronger. The aim of the present study was to examine TCP-filled restorative resins at different concentration levels at different time intervals to characterize the concentrations of Ca and PO4 ions released, and to measure the water sorption (WS) of these resins. An in vitro study was conducted by formulating resin composite using TCP as the filler mixed with EBPADMA, HmDMA, and HEMA as the resin matrix. One-hundred- sixty samples were prepared, 40 samples of each filler concentration (30 percent, 40 percent, 50 percent, and 60 percent) by weight. From each filler concentration, 5 samples of each of the 8 time points (time intervals of 4 h, 8 h, 12 h, 24 h, 3 d, 7 d, 14 d, and 21 d) were immersed in 100-ml deionized water. Calcium and PO4 ions were measured using atomic absorption spectroscopy and light spectroscopy, respectively. Water sorption (WS) was measured according to ISO 4049 specification and then the WS and the diffusion coefficient were calculated. The significance level was set at p = 0.001. The results indicated that Ca and PO4 ion release increased with increasing filler level at a rate faster than being linear. In addition, WS results were very high and failed to meet the ISO 4049 specification requirement. Diffusion coefficient results were also high. One-way ANOVA test for only 21-day data revealed that there is a statistically significant difference in filler level percent, and two-way ANOVA testing revealed that there is a statistically significant interaction between time and filler level percent on the Ca, PO4 released and WS. It can be concluded that the concentrations of Ca and PO4 released and WS were affected by composition of the monomers, filler level and type, dispersion, and the absence of coupling agent. Although this TCP-filled restorative material may release Ca and PO4, it cannot serve as a restorative material due to high WS values. Further study is needed to improve the material and evaluate its ability in promoting remineralization of the tooth structure in order for it to serve its purpose.Item The Mechanical Properties of Full-Contour Zirconia(2014) Janabi, Anmar Uday; Chu, Tien-Min Gabriel; Matis, Bruce A.; Lund, Melvin R., 1922-; Cochran, Michael A. (Michael Alan), 1944-; Cook, Norman Blaine, 1954-The objectives: 1. To compare the flexural strength, flexural modulus, and fracture toughness of specimens fabricated from recently marketed translucent full-contour zirconia, traditional zirconia, and lithium disilicate glass ceramic. 2. To compare the load-to-failure of crowns fabricated from recently marketed translucent full-contour zirconia, traditional zirconia, and lithium disilicate glass ceramic at their recommended tooth-reduction thickness. Methodology: Four groups of translucent zirconia (BruxZir, KDZ Bruxer, CAP FZ, Suntech zirconia), one group of traditional zirconia (CAP QZ) and IPS e.maxCAD) were tested. Twelve bars of each material were made and tested for flexural strength, and fracture toughness. Fracture patterns were imaged under SEM. Forty-eight crowns (8 from each group) were fabricated with CAD/CAM technique following manufacturers’ recommendations for the amount of tooth reduction. All the crowns were cemented to prepared epoxy resin dies with RelyX Unicem and tested for static load to failure in a universal machine. Result: In bar-shape samples, CAP QZ (traditional zirconia) showed the highest flexural strength (788.12 MPa), fracture toughness (6.85 MPa.m1/2), and fracture resistance (2489.8 N). All translucent zirconia groups show lower mechanical properties than QZ. However, there were no differences between translucent and traditional zirconia in the fracture resistance of the crown-shape samples. There was no significant difference in fracture resistance between IPS e.max crowns at recommended thickness and other zirconia crowns at recommended thickness. Conclusion: With less reduction of tooth structure, a high inherent strength and chip resistance make full-zirconia crowns a good alternative to porcelain-fused-to-metal crowns and all other ceramic crowns.