- Browse by Author
Browsing by Author "Labban, Nawaf"
Now showing 1 - 6 of 6
Results Per Page
Sort Options
Item COVID-19 Pandemic Driven Knowledge, Attitude, Clinical Practice, Distress Reactions, and Post-Traumatic Growth of Dental Care Providers in Riyadh City, Saudi Arabia: A Cross-Sectional Study(2021) Labban, Nawaf; Alfouzan, Afnan F.; Al-Shibani, Nouf; Al-Otaibi, Hanan N.; Al Taweel, Sara Mohammad; Al Ghanem, Shahad Hamad; Schrader, Stuart M.; Biomedical Sciences and Comprehensive Care, School of DentistryObjective: The present study aimed to assess knowledge, attitude, clinical practices, distress reactions, and post-traumatic growth of dentists during the COVID-19 pandemic in Riyadh City. Methodology: An online questionnaire was developed to assess various dental professionals from both governmental and private sectors during the early COVID-19 outbreak in Riyadh City, Saudi Arabia. The questionnaire was framed to assess the demographic variables, knowledge, attitude, and clinical practices towards handling the COVID-19 pandemic. Furthermore, the general anxiety disorder-7 (GAD-7), worry questionnaire items, short form of post-traumatic growth inventory (PTGI-SF), and life satisfaction questionnaire items were developed to assess the anxiety, worries, post-traumatic growth, and life satisfaction of dental care providers following the traumatic events. Data were analysed using SPSS 22.0 and R environment ver.3.2.2. Continuous measurement results were presented as mean ± SD, and categorical measurements results were presented in number (%). Results: Our study's significant findings revealed that a majority of the dentists were in the age group of 21-30 and practiced general dentistry. The study participants in age groups 51–60 and 41–50 years old showed more liability in perceiving COVID-19 as an extremely dangerous disease than 31–40 and 21–30 age groups. The majority of respondents (63.4%) had an anxiety scale score of greater than 40, followed by 22.8% with scores 20-40 and 13.9% with scores less than 20, respectively. The mean scores for the GAD-7 and the worry items were 8.24 ± 3.21 and 13.92 ± 4.77, respectively. The data showed that most survey participants had adopted moderate post-traumatic changes during the pandemic, as evident by their mean score of 34.17 ± 3.40. The life satisfaction of the participants was neutral, as demonstrated by their mean score of 20.16 ± 4.03. Conclusion: This study’s findings delineated that the COVID-19 pandemic situation has influenced dentists' mental health, with a moderate level of anxiety, and worries among other psychological symptoms. Furthermore, there was adequate knowledge regarding the COVID-19 among dentists; however, the pandemic affected the financial conditions of the respondents. There was a moderate level of post-traumatic growth and neutral life satisfaction of the dental providers.Item Evaluation of the Water Sorption and Solubility Behavior of Different Polymeric Luting Materials(MDPI, 2021-08-25) Labban, Nawaf; AlSheikh, Rasha; Lund, Melvin; Matis, Bruce A.; Moore, B. Keith; Cochran, Michael A.; Platt, Jeffrey A.; Cariology, Operative Dentistry and Dental Public Health, School of DentistryObjective: The study evaluated the water sorption (WSP) and water solubility (WSL) characteristics of different luting agents over a 180-day water storage period. Materials and Methods: Nine luting materials, i.e., conventional resin cement: Panavia F (PF), Rely X ARC (RA), self-adhesive resin cement: Rely X Unicem (RU), Breez (BZ), Maxcem Elite (MX), BisCem (BC) and resin-modified glass ionomer cement: FujiCem (FC), FujiPlus (FP) Rely X luting plus (RL) were assessed and fifty-two-disc specimens of each material were fabricated. All specimens were desiccated until a constant weight (W0) was reached. Thirteen specimens for each luting material were then randomly assigned to one of the four water immersion periods (7, 30, 90, and 180 days). After each period, the specimens were removed from the water and weighed to get W1. The samples were again desiccated for a second time and W2 was measured. Both WSP and WSL were determined by the following equations: WSP (%) = (W1 - W2) × 100/W0 and WSL (%) = (W0 - W2) × 100/W0. Assessments were performed following ISO standards. ANOVA was used to assess the effect of luting agent and time period on water sorption and solubility. Pair-wise comparisons were adjusted using Tukey's multiple comparison procedure. A significance level of 0.05 was used for all statistical tests. Results: The highest mean WSP and WSL (WSP/WSL) were demonstrated by resin-modified glass-ionomers (RL 18.32/3.25, FC 17.08/4.83, and FP 14.14/1.99), while resin luting agents showed lower WSP and WSL results (PF 1.6/0.67 and RA 1.76/0.46), respectively. The self-adhesive agents exhibited a wide range of WSP and WSL values (RU 1.86/0.13, BZ 4.66/0.93, and MX 3.68/1.11). Self-adhesive cement showed lower WSP and WSL compared with the resin-modified glass-ionomers (p < 0.05). All the materials reached equilibrium after 90-days. Conclusions: Resin-based luting materials have the lowest sorption and solubility. Rely X Unicem self-adhesive luting materials were comparable to resin luting materials for WSL and WSP. Resin-modified glass-ionomer showed the highest water sorption and solubility compared with both resin and self-adhesive materials.Item The influence of delayed light curing on the degree of conversion and polymerization contraction stress in dual-cured resin luting agents(Taylor & Francis, 2018) Labban, Nawaf; Iskander, Mounir; Platt, Jeffrey A.; Andres, Carl J.; Levon, John A.; Hovijitra, Suteera; Brown, David T.; Biomedical and Applied Sciences, School of DentistryThe aim of the study was to assess the effect of delayed photo-initiation on the polymerization contraction stress (PCS) and degree of conversion (DC) of a dual-cure resin-luting agent. Thirty-five disk (6 mm × 1 mm) samples (n = 10 each group) of dual cure resin luting agent for PCS assessment were fabricated and polymerized using two illuminated quartz rods. Based on the delay in photo-initiation, 30 disks were divided among six groups [group A-0 min (min) delay, group B-2 min, group C-4 min, group D-6 min, group E-8 min and group F-10 min]. A non-photoinitiated group (group G – chemical cure – n = 5) was included as control. The PCS for all specimens was assessed using a Tensometer. For DC evaluation thirty-five specimens were divided into seven groups with delays in photo-initiation (group H-0 min, group I-2 min, group J-4 min, group K-6 min, group L-8 min and group M-10 min, group N-chemical cure). DC was assessed using attenuated total reflectance spectroscopic technique. Statistical comparison among groups was performed using analysis of variance (α = 0.05). The maximum and minimum PCS and DC values with delayed photo-initiation was observed in group-C (3.34 MPa) & group-F (2.44 MPa); and group-M (0.78 MPa) and group-H (0.55 MPa) respectively. Chemically cured samples showed the least PCS (group-G, 1.94) and DC (group-N, 0.53) values in their respective categories. PCS significantly decreased with delayed photo-initiation. A significant increase in DC was noticed when photo-initiation was delayed in the dual cure resin luting agent.Item Influence of Toothbrush Abrasion and Surface Treatments on Roughness and Gloss of Polymer-Infiltrated Ceramics(MDPI, 2021-10-27) Labban, Nawaf; Al Amri, Mohammad D.; Alnafaiy, Sarah M.; Alhijji, Saleh M.; Alenizy, Mohammad A.; Iskandar, Mounir; Feitosa, Sabrina; Biomedical Sciences and Comprehensive Care, School of DentistryThe aim of this study was to compare the surface roughness and gloss of polymer-infiltrated ceramics after simulated in vitro toothbrushing in different storage mediums. Four polymer- infiltrated ceramics were evaluated, Lava ultimate (LU), Vita enamic (EN), Shofu (SH), and Crystal ultra (CU). The control group was a feldspathic ceramic, Vita Mark II (VM). One hundred and twenty specimens (12 × 14 × 2.5 mm) were prepared using a precision saw. For each material (n = 24), the specimens were allocated into two groups, polished and stained. The specimens of each group were stored (for 7 days) in either citric acid (0.2N) or distilled water. Data for surface gloss (ΔE*SCE-SCI) and roughness (Ra) were evaluated before (baseline) and after simulated toothbrushing. For toothbrushing simulation, a toothpaste slurry containing a toothpaste of 100 relative dentin abrasion (RDA) and 0.3 ml distilled water was used for 3650 cycles (7300 strokes) for each specimen. Data were analyzed using t-test and ANOVA. A p-value of ≤ to 0.05 was considered significant. The highest mean value of surface gloss was identified in CU (stained-water) (4.3 (0.47)) (ΔE*) and EN (stained-acid) (4.3 (1.00)) (ΔE*) specimens, whereas the lowest mean value was shown by SH (stained-acid) (2.04 (0.42)) (ΔE*) samples. The highest mean value of surface roughness was observed in SH (0.40 (0.99)) Ra (stained-acid) whereas the lowest in VM (0.13 (0.039)) Ra (polished- water). A significant difference (p < 0.05) was observed in surface roughness and gloss between the materials with simulated toothbrushing, except in VM and LU, respectively. Therefore, it can be concluded that simulated toothbrushing impacts on surface roughness and gloss, irrespective of the storage medium.Item Influence of toothbrush abrasion and surface treatments on the color and translucency of resin infiltrated hybrid ceramics(The Korean Academy of Prosthodontics, 2021) Labban, Nawaf; Al Amri, Mohammad; Alhijji, Saleh; Alnafaiy, Sarah; Alfouzan, Afnan; Iskandar, Mounir; Feitosa, Sabrina; Biomedical Sciences and Comprehensive Care, School of DentistryPurpose: The study compared the color change, lightness, and translucency of hybrid resin ceramics exposed to toothbrush abrasion and surface treatment. Materials and methods: Four hybrid ceramics [Lava Ultimate (LU), Vita Enamic (EN), Shofu HC (SH), and Crystal Ultra (CU)] were compared with a glass-ceramic (Vita Mark II) control. One hundred and twenty specimen blocks were prepared using a precision saw machine. Specimens in each material were divided into four subgroups based on the surface treatment (polishing or staining) and a storage medium (water or citric acid). Simulated tooth brushing with a mixture of 100 RDA (radioactive abrasives) with 0.3 ml distilled water was used for 3650 cycles (7300 strokes) for each specimen. Measurements for the color change, lightness, and translucency were measured after toothbrushing using a spectrophotometer. Statistical analysis compared outcomes using paired t-test, ANOVA, and Tukey post hoc test. Results: The maximum color change was identified in SH (stained acid) [1.44 (0.40)], whereas the lowest was identified in EN (polished water) [0.66 (0.16)] material. The maximum and minimum loss of surface translucency was observed in SH (polished water) [12.3 (0.52)] and EN (stained acid) [6.5 (0.55)] specimens, respectively. Lastly, loss of lightness was the highest in VM (polished acid) [69 (0.95)], whereas the lowest was observed in CU (stained water) [56.7 (0.86)]. Conclusion: The comparison presented a significant effect of toothbrush abrasion on translucency and lightness of the hybrid resin ceramics. Color change was not significantly influenced irrespective of the storage medium employed. Surface staining demonstrated the preservation and stability of color and optical properties under the influence of toothbrush abrasion and chemical trauma.Item Release and MMP-9 Inhibition Assessment of Dental Adhesive Modified with EGCG-Encapsulated Halloysite Nanotubes(MDPI, 2023-03-09) Alhijji, Saleh; Platt, Jeffrey A.; Alhotan, Abdulaziz; Labban, Nawaf; Bottino, Marco C.; Windsor, L. Jack; Biomedical Sciences and Comprehensive Care, School of DentistryDegradation of the collagen fibrils at the dentin-resin interface by the enzymatic activity of matrix metalloproteinases (MMPs) has been known to permit some dental restoration complications, such as microleakage, secondary caries, and, ultimately, restoration failures. This study aimed to evaluate a modified adhesive by adding an MMP inhibitor from green tea extract with and without nanotube encapsulation to sustain the drug release. Epigallocatechin-3-gallate (EGCG) and Halloysite nanotubes (HNTs) were prepared to produce three variant combinations of modified adhesive (EGCG, EGCG-encapsulated HNT, and EGCG-free HNT). The drug loading efficiency and EGCG release over time were evaluated using UV-vis spectrometry. MMP-mediated β-casein (BCN) cleavage rate assays were used to determine the ability of the EGCG in eluates of the adhesive to inhibit MMP-9 activities. For up to 8 weeks, HNT encapsulation reduced release to a statistically significant level. MMP-mediated β-casein cleavage rate assays showed a significant decrease for the EGCG groups compared to the non-EGCG adhesive groups. Furthermore, the use of HNT for EGCG encapsulation to modify a dental adhesive helped slow down the rate of EGCG release without impacting its MMP inhibitory capabilities, which may help to maintain the dentin-resin interface's integrity over the long term after dental restoration placement.