    Laser-treated stainless steel mini-screw implants: 3D surface roughness, bone-implant contact, and fracture resistance analysis
    (Oxford University Press, 2016-04) Kang, He-Kyong; Chu, Tien-Min; Dechow, Paul; Stewart, Kelton; Kyung, Hee-Moon; Liu, Sean Shih-Yao; Department of Orthodontics and Oral Facial Genetics, School of Dentistry
    BACKGROUND/OBJECTIVES: This study investigated the biomechanical properties and bone-implant intersurface response of machined and laser surface-treated stainless steel (SS) mini-screw implants (MSIs). MATERIAL AND METHODS: Forty-eight 1.3mm in diameter and 6mm long SS MSIs were divided into two groups. The control (machined surface) group received no surface treatment; the laser-treated group received Nd-YAG laser surface treatment. Half in each group was used for examining surface roughness (Sa and Sq), surface texture, and facture resistance. The remaining MSIs were placed in the maxilla of six skeletally mature male beagle dogs in a randomized split-mouth design. A pair with the same surface treatment was placed on the same side and immediately loaded with 200 g nickel-titanium coil springs for 8 weeks. After killing, the bone-implant contact (BIC) for each MSI was calculated using micro computed tomography. Analysis of variance model and two-sample t test were used for statistical analysis with a significance level of P <0.05. RESULTS: The mean values of Sa and Sq were significantly higher in the laser-treated group compared with the machined group (P <0.05). There were no significant differences in fracture resistance and BIC between the two groups. LIMITATION: animal study CONCLUSIONS/IMPLICATIONS: Laser treatment increased surface roughness without compromising fracture resistance. Despite increasing surface roughness, laser treatment did not improve BIC. Overall, it appears that medical grade SS has the potential to be substituted for titanium alloy MSIs.
  • Loading...
    Thumbnail Image
    Item
    Microdamage generation by tapered and cylindrical mini-screw implants after pilot drilling
    (2014-09) Taing-Watson, Emily; Katona, Thomas R.; Stewart, Kelton T.; Ghoneima, Ahmed; Chu, Gabriel T. M.; Kyung, Hee-Moon; Liu, Sean S.; Department of Orthodontics and Oral Facial Genetics, IU School of Dentistry
    Objective:  To investigate the relationship between mini-screw implant (MSI) diameter (1.6 vs 2.0 mm) and shape (tapered vs cylindrical) and the amount of microdamage generated during insertion. Materials and Methods:  Thirty-six cylindrical and 36 tapered MSIs, 6 mm long, were used in this study. Half of each shape was 1.6 mm in diameter, while the other half was 2.0 mm. After pilot drilling, four and five MSIs were inserted, respectively, into fresh cadaveric maxillae and mandibles of dogs. Bone blocks containing the MSIs were sectioned and ground parallel to the MSI axis. Epifluorescent microscopy was used to measure overall cortical thickness, crack length, and crack number adjacent to the MSI. Crack density and total microdamage burden per surface length were calculated. Three-way analysis of variance (ANOVA) was used to test the effects of jaw, and MSI shape and diameter. Pairwise comparisons were made to control the overall significance level at 5%. Results:  The larger (2.0 vs 1.6 mm) cylindrical MSIs increased the numbers, lengths, and densities of microcracks, and the total microdamage burden. The same diameter cylindrical and tapered MSIs generated a similar number of cracks and crack lengths. More total microdamage burden was created by the 2.0-mm cylindrical than the 2.0-mm tapered MSIs. Although higher crack densities were produced by the insertion of 1.6-mm tapered MSIs, there was no difference in total microdamage burden induced by 1.6-mm tapered and 1.6-mm cylindrical MSIs. Conclusions:  Pilot drilling is effective in reducing microdamage during insertion of tapered MSIs. To prevent excessive microdamage, large diameter and cylindrical MSIs should be avoided.