- Browse by Author
Browsing by Author "Johnstone, Peter A. S."
Now showing 1 - 3 of 3
Results Per Page
Sort Options
Item Acute toxicity in comprehensive head and neck radiation for nasopharynx and paranasal sinus cancers: cohort comparison of 3D conformal proton therapy and intensity modulated radiation therapy.(BMC, 2016) McDonald, Mark W.; Liu, Yuan; Moore, Michael G.; Johnstone, Peter A. S.; Department of Otolaryngology--Head & Neck Surgery, IU School of MedicineBackground: To evaluate acute toxicity endpoints in a cohort of patients receiving head and neck radiation with proton therapy or intensity modulated radiation therapy (IMRT). Methods: Forty patients received comprehensive head and neck radiation including bilateral cervical nodal radiation, given with or without chemotherapy, for tumors of the nasopharynx, nasal cavity or paranasal sinuses, any T stage, N0-2. Fourteen received comprehensive treatment with proton therapy, and 26 were treated with IMRT, either comprehensively or matched to proton therapy delivered to the primary tumor site. Toxicity endpoints assessed included g-tube dependence at the completion of radiation and at 3 months after radiation, opioid pain medication requirement compared to pretreatment normalized as equivalent morphine dose (EMD) at completion of treatment, and at 1 and 3 months after radiation. Results: In a multivariable model including confounding variables of concurrent chemotherapy and involved nodal disease, comprehensive head and neck radiation therapy using proton therapy was associated with a lower opioid pain requirement at the completion of radiation and a lower rate of gastrostomy tube dependence by the completion of radiation therapy and at 3 months after radiation compared to IMRT. Proton therapy was associated with statistically significant lower mean doses to the oral cavity, esophagus, larynx, and parotid glands. In subgroup analysis of 32 patients receiving concurrent chemotherapy, there was a statistically significant correlation with a greater opioid pain medication requirement at the completion of radiation and both increasing mean dose to the oral cavity and to the esophagus. Conclusions: Proton therapy was associated with significantly reduced radiation dose to assessed non-target normal tissues and a reduced rate of gastrostomy tube dependence and opioid pain medication requirements. This warrants further evaluation in larger studies, ideally with patient-reported toxicity outcomes and quality of life endpoints.Item Computed tomography imaging parameters for inhomogeneity correction in radiation treatment planning(Medknow Publications, 2016-01) Das, Indra J.; Cheng, Chee-Wai; Cao, Minsong; Johnstone, Peter A. S.; Department of Radiation Oncology, IU School of MedicineModern treatment planning systems provide accurate dosimetry in heterogeneous media (such as a patient' body) with the help of tissue characterization based on computed tomography (CT) number. However, CT number depends on the type of scanner, tube voltage, field of view (FOV), reconstruction algorithm including artifact reduction and processing filters. The impact of these parameters on CT to electron density (ED) conversion had been subject of investigation for treatment planning in various clinical situations. This is usually performed with a tissue characterization phantom with various density plugs acquired with different tube voltages (kilovoltage peak), FOV reconstruction and different scanners to generate CT number to ED tables. This article provides an overview of inhomogeneity correction in the context of CT scanning and a new evaluation tool, difference volume dose-volume histogram (DVH), dV-DVH. It has been concluded that scanner and CT parameters are important for tissue characterizations, but changes in ED are minimal and only pronounced for higher density materials. For lungs, changes in CT number are minimal among scanners and CT parameters. Dosimetric differences for lung and prostate cases are usually insignificant (<2%) in three-dimensional conformal radiation therapy and < 5% for intensity-modulated radiation therapy (IMRT) with CT parameters. It could be concluded that CT number variability is dependent on acquisition parameters, but its dosimetric impact is pronounced only in high-density media and possibly in IMRT. In view of such small dosimetric changes in low-density medium, the acquisition of additional CT data for financially difficult clinics and countries may not be warranted.Item Impact of proton beam availability on patient treatment schedule in radiation oncology(American Association of Physicists in Medicine, 2012-11-08) Miller, Eric D.; Derenchuk, Vladimir; Das, Indra J.; Johnstone, Peter A. S.; Radiation Oncology, School of MedicineProton beam therapy offers unique physical properties with potential for reduced toxicity and better patient care. There is an increased interest in radiation oncology centers to acquire proton therapy capabilities. The operation of a proton treatment center is quite different than a photon-based clinic because of the more complex technology involved, as well as the single proton beam source serving multiple treatment rooms with no backup source available. There is limited published data which investigates metrics that can be used to determine the performance of a proton facility. The purpose of this study is to evaluate performance metrics of Indiana University Cyclotron Operations (IUCO), including availability, mean time between failures, and mean time to repair, and to determine how changes in these metrics impact patient treatments. We utilized a computerized maintenance management system to log all downtime occurrences and servicing operations for the facility. These data were then used to calculate the availability as well as the mean time between failures and mean time to repair. Impact on patient treatments was determined by analyzing delayed and missed treatments, which were recorded in an electronic medical record and database maintained by the therapists. The availability of the IUCO proton beam has been increasing since beginning of operation in 2003 and averaged 96.9% for 2009 through 2011. The mean time between failures and mean time to repair were also determined and correlated with improvements in the maintenance and operating procedures of the facility, as well as environmental factors. It was found that events less than 15 minutes in duration have minimal impact on treatment delays, while events lasting longer than one hour may result in missed treatments. The availability of the proton beam was more closely correlated with delayed than with missed treatments, demonstrating the utility and limitations of the availability metric. In conclusion, we suggest that the availability metric and other performance parameters, such as the mean time between failures and the mean time to repair, should be used in combination with downtime impact on patient treatments in order to adequately evaluate the operational success of a proton therapy facility.